cs.CVOct 2, 2025

Can MLLMs Perceive and Describe Medical Image Quality Beyond Scores?

Authors: Jiyao Liu, Jinjie Wei, Wanying Qu, Chenglong Ma, Junzhi Ning, Yunheng Li, Ying Chen, Jiafan Zhang, 

Organizations: Fudan University · Shanghai Artificial Intelligence Laboratory · University of Cambridge

Abstract

Medical Image Quality Assessment (IQA) serves as a critical safety gate for clinical AI, yet existing approaches rely on scalar metrics that fail to capture the descriptive, expert-like evaluation process central to clinical practice. We introduce MedQ-Bench, a comprehensive benchmark for language-based medical IQA evaluation with MLLMs, establishing a perception--description paradigm across 5 imaging modalities and over 40 quality attributes. The benchmark comprises two complementary tasks: MedQ-Perception probes low-level visual attribute discrimination via 2,600 expert-annotated perceptual queries; MedQ-Description covers both no-reference and comparison description sub-tasks with 708 expert-annotated samples, evaluated through a four-dimensional judging protocol. Comprehensive evaluation of 23 state-of-the-art MLLMs reveals that current models exhibit only preliminary and unstable capabilities, and highlights the urgent need for targeted optimization of MLLMs in medical IQA. Project & Dataset: https://github.com/liujiyaoFDU/MedQ-Bench

Figures & tables

Appendix figures & tables19 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Mar 20, 2026

MedQ-Engine: A Closed-Loop Data Engine for Evolving MLLMs in Medical Image Quality Assessment

Medical image quality assessment (Med-IQA) is a prerequisite for clinical AI deployment, yet multimodal large language models (MLLMs) still fall substantially short of human experts, particularly when required to provide descriptive assessments with clinical reasoning beyond simple quality scores. However, improving them is hindered by the high cost of acquiring descriptive annotations and by the inability of one-time data collection to adapt to the model's evolving weaknesses. To address these challenges, we propose MedQ-Engine, a closed-loop data engine that iteratively evaluates the model to discover failure prototypes via data-driven clustering, explores a million-scale image pool using these prototypes as retrieval anchors with progressive human-in-the-loop annotation, and evolves through quality-assured fine-tuning, forming a self-improving cycle. Models are evaluated on complementary perception and description tasks. An entropy-guided routing mechanism triages annotations to minimize labeling cost. Experiments across five medical imaging modalities show that MedQ-Engine elevates an 8B-parameter model to surpass GPT-4o by over 13% and narrow the gap with human experts to only 4.34%, using only 10K annotations with more than 4x sample efficiency over random sampling.
Mar 8, 2026

MedQ-Deg: A Multidimensional Benchmark for Evaluating MLLMs Across Medical Image Quality Degradations

Despite impressive performance on standard benchmarks, multimodal large language models (MLLMs) face critical challenges in real-world clinical environments where medical images inevitably suffer various quality degradations. Existing benchmarks exhibit two key limitations: (1) absence of large-scale, multidimensional assessment across medical image quality gradients and (2) no systematic confidence calibration analysis. To address these gaps, we present MedQ-Deg, a comprehensive benchmark for evaluating medical MLLMs under image quality degradations. MedQ-Deg provides multi-dimensional evaluation spanning 18 distinct degradation types, 30 fine-grained capability dimensions, and 7 imaging modalities, with 24,894 question-answer pairs. Each degradation is implemented at 3 severity degrees, calibrated by expert radiologists. We further introduce Calibration Shift metric, which quantifies the gap between a model's perceived confidence and actual performance to assess metacognitive reliability under degradation. Our comprehensive evaluation of 40 mainstream MLLMs reveals several critical findings: (1) overall model performance degrades systematically as degradation severity increases, (2) models universally exhibit the AI Dunning-Kruger Effect, maintaining inappropriately high confidence despite severe accuracy collapse, and (3) models display markedly differentiated behavioral patterns across capability dimensions, imaging modalities, and degradation types. We hope MedQ-Deg drives progress toward medical MLLMs that are robust and trustworthy in real clinical practice.
Jul 2, 2026

Assessing VLM Reliability for Medical Image Quality Evaluation Under Corruption and Bias

Vision-Language Models (VLMs) are increasingly applied in medical tasks such as pathology description, report generation, and visual question answering. Medical Image Quality Assessment (MIQA) supports diagnostic accuracy and patient safety by determining whether images meet the standards required for clinical decision-making. Automating MIQA with VLMs may reduce workload, but their behavior under real-world conditions, where images may be degraded or textual context may affect judgments, should be further explored before deployment. We benchmark VLMs on medical image quality using the MediMeta-C dataset zero-shot across seven corruption types and five severity levels. We evaluate sensitivity to degradation patterns, the effect of corruptions on embedding geometry, and whether textual attributes (demographics, expertise, infrastructure, institution) alter scores. Across 16 VLMs and seven modalities, pixelation produced the largest score reductions (mean -20.58%, up to -34.4% for OCT), whereas brightness had limited effect (-0.81%). Embedding displacement was associated with score changes. Same-family models showed correlations of 0.67-0.83; some produced increases up to +31% for corrupted mammography. Textual attributes affected scores: institutional prestige raised them +17.15%, and equipment age lowered them -14.7%. The largest changes were +95.62% (InternVL-8B) and -37.7% (MedGemma). Current VLMs show limitations for medical image quality assessment. Pixelation, a privacy-preserving transformation, reduces performance, indicating a trade-off between patient privacy and reliability. Sensitivity to contextual metadata indicates limited objectivity and marks metadata as a privacy and bias source. Privacy protection and objective quality assessment are related requirements for use.