Medical Image Quality Assessment (IQA) serves as a critical safety gate for clinical AI, yet existing approaches rely on scalar metrics that fail to capture the descriptive, expert-like evaluation process central to clinical practice. We introduce MedQ-Bench, a comprehensive benchmark for language-based medical IQA evaluation with MLLMs, establishing a perception--description paradigm across 5 imaging modalities and over 40 quality attributes. The benchmark comprises two complementary tasks: MedQ-Perception probes low-level visual attribute discrimination via 2,600 expert-annotated perceptual queries; MedQ-Description covers both no-reference and comparison description sub-tasks with 708 expert-annotated samples, evaluated through a four-dimensional judging protocol. Comprehensive evaluation of 23 state-of-the-art MLLMs reveals that current models exhibit only preliminary and unstable capabilities, and highlights the urgent need for targeted optimization of MLLMs in medical IQA. Project & Dataset: https://github.com/liujiyaoFDU/MedQ-Bench
Figures & tables
Figure 1: Comparison of Description-IQA with score-based IQA paradigm. Unlike purely numerical scores, Description-IQA identifies distortion types and their relative impact, yielding results more consistent with Human-IQA.
Figure 3: Examples of question types in MedQ-Bench, covering MCQA perception tasks, open-ended description, and pair comparison.
Sub-categories
Perception
Description
Model (variant)
Yes-or-No ↑
What ↑
How ↑
Overall ↑
Comp. ↑
Prec. ↑
Cons. ↑
Qual. ↑
Overall ↑
random guess
50.00%
28.48%
33.30%
37.94%
Non-experts
67.50%
57.50%
57.50%
62.50%
-
-
-
-
-
Human experts
88.50%
77.50%
77.50%
82.50%
1.524
1.483
1.887
1.623
6.502
Open-Source General Models
Qwen2.5-VL-Instruct (7B)
57.89%
48.45%
54.40%
54.71%
0.715
0.670
1.855
1.127
4.367
Table 1: Performance of different models on the MCQA perception and description tasks.
Figure 4: Performance analysis of MLLMs across different evaluation dimensions: (a) Different degradation level performance, (b) general vs modality-specific question.
Model
Comp. ↑
Prec. ↑
Cons. ↑
Qual. ↑
Overall ↑
Human experts
1.653
1.682
1.963
1.714
7.003
Open-Source General Models
Qwen2.5-VL-7B
0.714
0.902
1.316
1.143
4.075
Qwen2.5-VL-32B
0.692
0.752
1.895
0.962
4.301
Qwen2.5-VL-72B
0.737
0.977
1.233
1.113
4.060
InternVL3-8B
0.985
1.278
1.797
1.474
5.534
Table 2: Detailed comparison description performance scores across four evaluation dimensions for all models.
Figure 5: Visual comparison of overall description performance patterns across model categories.
Appendix figures & tables19 assets
Supplementary material from the paper’s appendix.
Appendix
Modality
Source Type
Dataset
Samples
% of Modality
Total Samples
CT
Authentic
Radiopaedia
239
27.2%
878
Simulate
AAPM CT-MAR ( Haneda et al., 2025 )
613
69.8%
AI-generated
AIsynthesis (subset)
26
3.0%
MRI
Authentic
Radiopaedia
130
15.3%
848
Authentic
MR-ART ( Nárai et al., 2022 )
68
8.0%
Authentic
FSL Example MRI Artifacts
43
5.1%
Appendix
Table 3: Comprehensive breakdown of dataset composition.
Figure 6: Interface for the MedQ-MCQA dataset.
Figure 7: Interface for the MedQ-Description dataset.
Source Type
Authentic
Simulate
AI-Generated
Percentage
41.3%
33.9%
24.8%
Appendix
Table 4: Distribution of MedQ-Bench dataset by source type.
Question Type
Percentage
Modality-specific
57.2%
General
42.8%
Total
100.0%
Appendix
Table 5: MedQ-Perception: Distribution of tasks by question type.
Degradation Level
Percentage
No Degradation
23.8%
Mild Degradation
44.6%
Severe Degradation
31.6%
Total
100.0%
Appendix
Table 6: MedQ-Perception: Distribution of degradation severity levels.
Figure 8: Distribution of low-level attributions across imaging modalities and distortion types in MedQ-Bench.
Model
Comp. ↑
Prec. ↑
Cons. ↑
Qual. ↑
Overall ↑
Qwen2.5-VL-Instruct (7B)
0.769
0.723
1.878
1.168
4.538
Qwen2.5-VL-Instruct (32B)
1.082
0.959
1.982
1.335
5.358
InternVL3 (8B)
1.005
0.950
1.905
1.421
5.281
InternVL3 (38B)
0.996
0.973
1.932
1.448
5.349
Qwen2.5-VL-Instruct (72B)
0.932
0.923
1.896
1.412
5.163
BiMediX2 (8B)
0.405
0.428
0.315
0.715
1.863
Appendix
Table 7: Few-shot evaluation results on No-reference Description tasks.
Model
CT
Histo.
MRI
Endos.
Retinal
GPT-5
71.47%
65.43%
75.90%
60.89%
70.09%
GPT-4o
72.85%
58.33%
64.75%
60.44%
66.67 %
Grok-4
70.14%
59.37 %
65.93 %
64.49%
61.40%
Gemini-2.5-Pro
67.04%
53.40%
60.79%
60.89%
59.83%
Mistral-Medium-3
65.93%
38.58%
61.51%
65.33%
61.54%
Claude-4-Sonnet
64.27%
54.63%
55.04%
65.33%
65.81%
Appendix
Table 8: Detailed perception accuracy results across five imaging modalities.
Model
Group
Comp.
Prec.
Cons.
Qual. Acc.
Total
GPT-5
Overall
1.293
1.556
1.925
1.564
6.338
Fine-grained
1.301
1.495
1.903
1.476
6.175
Coarse-grained
1.267
1.767
2.000
1.867
6.900
GPT-4o
Overall
1.105
1.414
1.632
1.564
5.714
Fine-grained
1.155
1.388
1.583
1.534
5.660
Coarse-grained
0.933
1.500
1.800
1.667
5.900
Appendix
Table 9: Detailed numerical results for paired comparison description tasks across models, corresponding to Figure 5 .
Figure 9: Representative QA examples demonstrating typical question-answer patterns in MedQ-Bench across different medical imaging modalities and quality assessment scenarios.
Figure 10: Representative no-reference reasoning image examples demonstrating typical question-answer patterns in MedQ-Bench across different models.
Figure 11: Representative paired image examples demonstrating typical question-answer patterns in MedQ-Bench across different models.
Modality
Error Rate
Endoscopy
39.11%
Histopathology
34.57%
Fundus
29.91%
CT
25.76%
MRI
24.10%
Appendix
Table 10: GPT-5 error rates across imaging modalities on perception tasks, ranked by difficulty.
Metric
Completeness
Preciseness
Consistency
Quality Accuracy
Cohen’s κ
0.843
0.817
0.856
0.884
Appendix
Table 11: Inter-annotator agreement (Cohen’s κ ) for description task.
Figure 12: Confusion matrices showing alignment between human expert scores and GPT-4o automated evaluation across four evaluation dimensions.
Metric
Completeness
Preciseness
Consistency
Quality Accuracy
κw
0.774
0.876
0.840
0.985
Appendix
Table 12: Quadratic weighted Cohen’s κw values for human–AI alignment across evaluation dimensions.
Metric
Completeness
Preciseness
Consistency
Quality Accuracy
κw
0.702
0.791
0.755
0.952
Appendix
Table 13: Human–AI alignment in the lowest-quality tier (bottom third by human score). Despite challenging cases, alignment remains robust across all evaluation dimensions.
Model
GPT-4o
Claude
Gemini
ICC
ICC 95% CI
MAD (Claude)
MAD (Gemini)
Qwen2.5-VL-Instruct (7B)
4.367
4.376
4.371
0.984
[0.980, 0.987]
0.009
0.004
Qwen2.5-VL-Instruct (32B)
5.272
5.294
5.308
0.992
[0.990, 0.994]
0.022
0.036
InternVL3 (8B)
4.983
4.995
4.968
0.986
[0.982, 0.989]
0.012
0.015
InternVL3 (38B)
4.965
4.977
4.977
0.990
[0.988, 0.992]
0.012
0.012
Qwen2.5-VL-Instruct (72B)
4.982
4.932
4.959
0.988
[0.985, 0.990]
0.050
0.023
BiMediX2 (8B)
1.721
1.692
1.719
0.954
[0.942, 0.963]
0.029
0.002
Appendix
Table 14: Multi-judge validation results showing overall description scores from three independent LLM judges and inter-judge consistency metrics. MAD (Claude) and MAD (Gemini) represent MAD between GPT-4o scores and Claude/Gemini scores respectively. Score differences across judges are minimal, and high ICC values ( > 0.95) confirm excellent agreement, indicating no systematic self-preference bias.
Medical image quality assessment (Med-IQA) is a prerequisite for clinical AI deployment, yet multimodal large language models (MLLMs) still fall substantially short of human experts, particularly when required to provide descriptive assessments with clinical reasoning beyond simple quality scores. However, improving them is hindered by the high cost of acquiring descriptive annotations and by the inability of one-time data collection to adapt to the model's evolving weaknesses. To address these challenges, we propose MedQ-Engine, a closed-loop data engine that iteratively evaluates the model to discover failure prototypes via data-driven clustering, explores a million-scale image pool using these prototypes as retrieval anchors with progressive human-in-the-loop annotation, and evolves through quality-assured fine-tuning, forming a self-improving cycle. Models are evaluated on complementary perception and description tasks. An entropy-guided routing mechanism triages annotations to minimize labeling cost. Experiments across five medical imaging modalities show that MedQ-Engine elevates an 8B-parameter model to surpass GPT-4o by over 13% and narrow the gap with human experts to only 4.34%, using only 10K annotations with more than 4x sample efficiency over random sampling.
Jiyao Liu, Junzhi Ning, Wanying Qu +4
Fudan University, Shanghai, China · Shanghai Artificial Intelligence Laboratory, Shanghai, China
Despite impressive performance on standard benchmarks, multimodal large language models (MLLMs) face critical challenges in real-world clinical environments where medical images inevitably suffer various quality degradations. Existing benchmarks exhibit two key limitations: (1) absence of large-scale, multidimensional assessment across medical image quality gradients and (2) no systematic confidence calibration analysis. To address these gaps, we present MedQ-Deg, a comprehensive benchmark for evaluating medical MLLMs under image quality degradations. MedQ-Deg provides multi-dimensional evaluation spanning 18 distinct degradation types, 30 fine-grained capability dimensions, and 7 imaging modalities, with 24,894 question-answer pairs. Each degradation is implemented at 3 severity degrees, calibrated by expert radiologists. We further introduce Calibration Shift metric, which quantifies the gap between a model's perceived confidence and actual performance to assess metacognitive reliability under degradation. Our comprehensive evaluation of 40 mainstream MLLMs reveals several critical findings: (1) overall model performance degrades systematically as degradation severity increases, (2) models universally exhibit the AI Dunning-Kruger Effect, maintaining inappropriately high confidence despite severe accuracy collapse, and (3) models display markedly differentiated behavioral patterns across capability dimensions, imaging modalities, and degradation types. We hope MedQ-Deg drives progress toward medical MLLMs that are robust and trustworthy in real clinical practice.
Jiyao Liu, Junzhi Ning, Chenglong Ma +14
Fudan University, Shanghai, China · Shanghai AI Lab, Shanghai, China · Shanghai Jiaotong University, Shanghai, China +1
Vision-Language Models (VLMs) are increasingly applied in medical tasks such as pathology description, report generation, and visual question answering. Medical Image Quality Assessment (MIQA) supports diagnostic accuracy and patient safety by determining whether images meet the standards required for clinical decision-making. Automating MIQA with VLMs may reduce workload, but their behavior under real-world conditions, where images may be degraded or textual context may affect judgments, should be further explored before deployment. We benchmark VLMs on medical image quality using the MediMeta-C dataset zero-shot across seven corruption types and five severity levels. We evaluate sensitivity to degradation patterns, the effect of corruptions on embedding geometry, and whether textual attributes (demographics, expertise, infrastructure, institution) alter scores. Across 16 VLMs and seven modalities, pixelation produced the largest score reductions (mean -20.58%, up to -34.4% for OCT), whereas brightness had limited effect (-0.81%). Embedding displacement was associated with score changes. Same-family models showed correlations of 0.67-0.83; some produced increases up to +31% for corrupted mammography. Textual attributes affected scores: institutional prestige raised them +17.15%, and equipment age lowered them -14.7%. The largest changes were +95.62% (InternVL-8B) and -37.7% (MedGemma). Current VLMs show limitations for medical image quality assessment. Pixelation, a privacy-preserving transformation, reduces performance, indicating a trade-off between patient privacy and reliability. Sensitivity to contextual metadata indicates limited objectivity and marks metadata as a privacy and bias source. Privacy protection and objective quality assessment are related requirements for use.
Sofiane Ouaari, Kevin Vorwalder, Nico Pfeifer
Methods in Medical Informatics, Department of Computer Science, University of Tuebingen, Germany. · Institute for Bioinformatics and Medical Informatics (IBMI), University of Tuebingen, Germany.