Medical Image Quality Assessment (IQA) serves as a critical safety gate for clinical AI, yet existing approaches rely on scalar metrics that fail to capture the descriptive, expert-like evaluation process central to clinical practice. We introduce MedQ-Bench, a comprehensive benchmark for language-based medical IQA evaluation with MLLMs, establishing a perception--description paradigm across 5 imaging modalities and over 40 quality attributes. The benchmark comprises two complementary tasks: MedQ-Perception probes low-level visual attribute discrimination via 2,600 expert-annotated perceptual queries; MedQ-Description covers both no-reference and comparison description sub-tasks with 708 expert-annotated samples, evaluated through a four-dimensional judging protocol. Comprehensive evaluation of 23 state-of-the-art MLLMs reveals that current models exhibit only preliminary and unstable capabilities, and highlights the urgent need for targeted optimization of MLLMs in medical IQA. Project & Dataset: https://github.com/liujiyaoFDU/MedQ-Bench
Figures & tables
Figure 1: Comparison of Description-IQA with score-based IQA paradigm. Unlike purely numerical scores, Description-IQA identifies distortion types and their relative impact, yielding results more consistent with Human-IQA.
Figure 3: Examples of question types in MedQ-Bench, covering MCQA perception tasks, open-ended description, and pair comparison.
Sub-categories
Perception
Description
Model (variant)
Yes-or-No ↑
What ↑
How ↑
Overall ↑
Comp. ↑
Prec. ↑
Cons. ↑
Qual. ↑
Overall ↑
random guess
50.00%
28.48%
33.30%
37.94%
Non-experts
67.50%
57.50%
57.50%
62.50%
-
-
-
-
-
Human experts
88.50%
77.50%
77.50%
82.50%
1.524
1.483
1.887
1.623
6.502
Open-Source General Models
Qwen2.5-VL-Instruct (7B)
57.89%
48.45%
54.40%
54.71%
0.715
0.670
1.855
1.127
4.367
Table 1: Performance of different models on the MCQA perception and description tasks.
Figure 4: Performance analysis of MLLMs across different evaluation dimensions: (a) Different degradation level performance, (b) general vs modality-specific question.
Model
Comp. ↑
Prec. ↑
Cons. ↑
Qual. ↑
Overall ↑
Human experts
1.653
1.682
1.963
1.714
7.003
Open-Source General Models
Qwen2.5-VL-7B
0.714
0.902
1.316
1.143
4.075
Qwen2.5-VL-32B
0.692
0.752
1.895
0.962
4.301
Qwen2.5-VL-72B
0.737
0.977
1.233
1.113
4.060
InternVL3-8B
0.985
1.278
1.797
1.474
5.534
Table 2: Detailed comparison description performance scores across four evaluation dimensions for all models.
Figure 5: Visual comparison of overall description performance patterns across model categories.
Appendix figures & tables19 assets
Supplementary material from the paper’s appendix.
Appendix
Modality
Source Type
Dataset
Samples
% of Modality
Total Samples
CT
Authentic
Radiopaedia
239
27.2%
878
Simulate
AAPM CT-MAR ( Haneda et al., 2025 )
613
69.8%
AI-generated
AIsynthesis (subset)
26
3.0%
MRI
Authentic
Radiopaedia
130
15.3%
848
Authentic
MR-ART ( Nárai et al., 2022 )
68
8.0%
Authentic
FSL Example MRI Artifacts
43
5.1%
Appendix
Table 3: Comprehensive breakdown of dataset composition.
Figure 6: Interface for the MedQ-MCQA dataset.
Figure 7: Interface for the MedQ-Description dataset.
Source Type
Authentic
Simulate
AI-Generated
Percentage
41.3%
33.9%
24.8%
Appendix
Table 4: Distribution of MedQ-Bench dataset by source type.
Question Type
Percentage
Modality-specific
57.2%
General
42.8%
Total
100.0%
Appendix
Table 5: MedQ-Perception: Distribution of tasks by question type.
Degradation Level
Percentage
No Degradation
23.8%
Mild Degradation
44.6%
Severe Degradation
31.6%
Total
100.0%
Appendix
Table 6: MedQ-Perception: Distribution of degradation severity levels.
Figure 8: Distribution of low-level attributions across imaging modalities and distortion types in MedQ-Bench.
Model
Comp. ↑
Prec. ↑
Cons. ↑
Qual. ↑
Overall ↑
Qwen2.5-VL-Instruct (7B)
0.769
0.723
1.878
1.168
4.538
Qwen2.5-VL-Instruct (32B)
1.082
0.959
1.982
1.335
5.358
InternVL3 (8B)
1.005
0.950
1.905
1.421
5.281
InternVL3 (38B)
0.996
0.973
1.932
1.448
5.349
Qwen2.5-VL-Instruct (72B)
0.932
0.923
1.896
1.412
5.163
BiMediX2 (8B)
0.405
0.428
0.315
0.715
1.863
Appendix
Table 7: Few-shot evaluation results on No-reference Description tasks.
Model
CT
Histo.
MRI
Endos.
Retinal
GPT-5
71.47%
65.43%
75.90%
60.89%
70.09%
GPT-4o
72.85%
58.33%
64.75%
60.44%
66.67 %
Grok-4
70.14%
59.37 %
65.93 %
64.49%
61.40%
Gemini-2.5-Pro
67.04%
53.40%
60.79%
60.89%
59.83%
Mistral-Medium-3
65.93%
38.58%
61.51%
65.33%
61.54%
Claude-4-Sonnet
64.27%
54.63%
55.04%
65.33%
65.81%
Appendix
Table 8: Detailed perception accuracy results across five imaging modalities.
Model
Group
Comp.
Prec.
Cons.
Qual. Acc.
Total
GPT-5
Overall
1.293
1.556
1.925
1.564
6.338
Fine-grained
1.301
1.495
1.903
1.476
6.175
Coarse-grained
1.267
1.767
2.000
1.867
6.900
GPT-4o
Overall
1.105
1.414
1.632
1.564
5.714
Fine-grained
1.155
1.388
1.583
1.534
5.660
Coarse-grained
0.933
1.500
1.800
1.667
5.900
Appendix
Table 9: Detailed numerical results for paired comparison description tasks across models, corresponding to Figure 5 .
Figure 9: Representative QA examples demonstrating typical question-answer patterns in MedQ-Bench across different medical imaging modalities and quality assessment scenarios.
Figure 10: Representative no-reference reasoning image examples demonstrating typical question-answer patterns in MedQ-Bench across different models.
Figure 11: Representative paired image examples demonstrating typical question-answer patterns in MedQ-Bench across different models.
Modality
Error Rate
Endoscopy
39.11%
Histopathology
34.57%
Fundus
29.91%
CT
25.76%
MRI
24.10%
Appendix
Table 10: GPT-5 error rates across imaging modalities on perception tasks, ranked by difficulty.
Metric
Completeness
Preciseness
Consistency
Quality Accuracy
Cohen’s κ
0.843
0.817
0.856
0.884
Appendix
Table 11: Inter-annotator agreement (Cohen’s κ ) for description task.
Figure 12: Confusion matrices showing alignment between human expert scores and GPT-4o automated evaluation across four evaluation dimensions.
Metric
Completeness
Preciseness
Consistency
Quality Accuracy
κw
0.774
0.876
0.840
0.985
Appendix
Table 12: Quadratic weighted Cohen’s κw values for human–AI alignment across evaluation dimensions.
Metric
Completeness
Preciseness
Consistency
Quality Accuracy
κw
0.702
0.791
0.755
0.952
Appendix
Table 13: Human–AI alignment in the lowest-quality tier (bottom third by human score). Despite challenging cases, alignment remains robust across all evaluation dimensions.
Model
GPT-4o
Claude
Gemini
ICC
ICC 95% CI
MAD (Claude)
MAD (Gemini)
Qwen2.5-VL-Instruct (7B)
4.367
4.376
4.371
0.984
[0.980, 0.987]
0.009
0.004
Qwen2.5-VL-Instruct (32B)
5.272
5.294
5.308
0.992
[0.990, 0.994]
0.022
0.036
InternVL3 (8B)
4.983
4.995
4.968
0.986
[0.982, 0.989]
0.012
0.015
InternVL3 (38B)
4.965
4.977
4.977
0.990
[0.988, 0.992]
0.012
0.012
Qwen2.5-VL-Instruct (72B)
4.982
4.932
4.959
0.988
[0.985, 0.990]
0.050
0.023
BiMediX2 (8B)
1.721
1.692
1.719
0.954
[0.942, 0.963]
0.029
0.002
Appendix
Table 14: Multi-judge validation results showing overall description scores from three independent LLM judges and inter-judge consistency metrics. MAD (Claude) and MAD (Gemini) represent MAD between GPT-4o scores and Claude/Gemini scores respectively. Score differences across judges are minimal, and high ICC values ( > 0.95) confirm excellent agreement, indicating no systematic self-preference bias.
Methods in Medical Informatics, Department of Computer Science, University of Tuebingen, Germany. · Institute for Bioinformatics and Medical Informatics (IBMI), University of Tuebingen, Germany.