cs.CVOct 13, 2025

Benchmarking Deep Learning Models for Laryngeal Cancer Staging Using the LaryngealCT Dataset

Authors: Nivea RoySon TranAtul SajjanharK. DevarajaPrakashini KoteshwaraYong XiangDivya Rao

Abstract

Laryngeal cancer imaging research lacks standardised public datasets to enable reproducible deep learning (DL) model development. We present LaryngealCT, a curated benchmark of 1,029 computed tomography (CT) scans aggregated from six collections from The Cancer Imaging Archive (TCIA). Uniform 1 mm isotropic volumes of interest encompassing the larynx were extracted using a weakly supervised parameter search framework validated by clinical experts. Six 3D DL architectures (custom 3D CNN, ResNet18,50,101, DenseNet121 and MedicalNet-pretrained ResNet50) were benchmarked on (i) early (Tis,T1,T2) vs. advanced (T3,T4) and (ii) T4 vs. non-T4 classification tasks. On the independent test set, the 3D CNN achieved the strongest overall performance across global and per-class metrics (Accuracy 0.854, F1-macro 0.841) in early vs. advanced classification. In the T4 task, AU-ROC values exceeded 0.82 for most models, but sensitivity for T4 disease remained limited (less than or equal to 0.412), with ResNet101 showing the most promising calibrated T4 recall (0.706. Model explainability assessed using GradCAMpp with thyroid cartilage overlays for T4 classification task revealed anatomically plausible peri-cartilage activations, although spatial overlap was modest. Through open-source data, pretrained models, and integrated explainability tools, LaryngealCT offers a reproducible foundation for AI-driven research to support future clinical decision-making in laryngeal oncology.

Explore similar work

Jul 20, 2026cs.CV

Medical Imaging Fusing Vision Transformer: Laryngeal Cancer Screening with Explanation

Early and timely screening of laryngeal cancer is crucial for improving clinical outcomes. In recent years, NBI endoscopy has become a standard diagnostic tool for the detection of laryngeal lesions. However, its effective use requires well-trained clinicians and the procedure is time-consuming and subject to interobserver variability. In this context, the application of artificial intelligence (AI) offers a promising solution to support clinical decision-making. In this work, we proposed applying transformer and attention mechanism for analyzing the narrow band imaging and distinguish benign and malignant lesions. Results show it has good classification performance with F1 (82.72%), accuracy(82.33%). In addition, the result of laryngeal cancer screening is explainable for clinicians. The explainability is utilizing the state of art segmentation method (MedSAM) to provide the useful pathological information area for clinicians. The proposed methodology fusing classification and segmentation provides a translating on laryngeal cancer screening.
Haiyang Wang, Luca Mainardi
Jun 14, 2026cs.CV

Trusting Right Predictions for Wrong Reasons: A LIME Based Analysis of Deep Learning Interpretability in Lung Cancer Diagnosis

Lung cancer is the leading cause of cancer-related mortality, with approximately 2.5 million new cases and 1.8 million deaths annually, making reliable diagnosis a clinical priority. Although deep learning models have achieved strong performance in lung cancer classification, evaluation has largely focused on predictive accuracy, leaving their decision-making processes insufficiently examined. This study compares three architecturally distinct models: a Convolutional Neural Network (CNN), a pretrained ResNet50, and a Vision Transformer (ViT), trained on the IQ-OTH/NCCD lung cancer CT dataset. Local Interpretable Model-Agnostic Explanations (LIME) were applied to investigate model reasoning. In addition to standard performance metrics, a dual-correlation framework was introduced to measure both prediction agreement and explanation agreement across model pairs. All three models achieved strong classification performance, with ResNet50 attaining 98.61% accuracy, CNN 97.91%, and ViT 93.75%, while all achieved ROC-AUC scores of 0.99. Prediction correlations exceeded 0.99 across all model pairs, indicating highly consistent outputs. However, LIME explanation correlations remained below 0.26, revealing substantial differences in the image regions used to reach those predictions. Analysis of misclassified samples further identified a consistent spatial pattern: incorrect predictions were associated with attention outside the lung parenchyma, whereas correct predictions focused primarily within lung regions. These findings demonstrate that prediction agreement is a poor proxy for reasoning consistency, and that interpretability evaluation must be treated as an independent validation criterion alongside predictive performance in clinical AI systems.
Samarpan Poudel, Vladislav D Veksler
Jun 5, 2026cs.CV

DALE-CT: Depth-Aware Foundation Models for Computed Tomography

Recent breakthroughs in self-supervised learning (SSL), such as the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA), alongside successes in integrating visual encoders with language models, have driven the demand for adaptable, high-capacity vision encoders in Computed Tomography (CT). In this work, we explore 2D slice-based architectures as a flexible alternative to native 3D models for processing volumetric CT data. Using the CT-RATE dataset, we trained DALE-CT (Depth-Aware Latent-Euclidean Computed Tomography), a 2D model family built entirely from scratch using LeJEPA, and compared its performance against a continually pre-trained DINOv2 baseline. To enhance representation quality, we developed a novel 3D depth-aware pre-training strategy anchored by dense auxiliary supervision from both automated anatomical masks and human-annotated abnormalities. Under linear probe evaluation with Multiple Instance Learning (MIL) for multi-abnormality detection, the frozen backbone of this dual-supervised model (DALE-CT-2S) achieves a Macro AUROC of 0.833. This performance demonstrates near-parity with state-of-the-art 3D vision-language models, achieved entirely from scratch with significantly less data and no textual supervision. To ensure reproducibility, all training code, evaluation scripts, and model weights have been made publicly available.
Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty +3