MedForj: An open, large-scale foundational generative prior for high-resolution 3D brain MRI

Authors: Samuel W. Remedios, Aaron Carass, Jerry L. Prince, Blake E. Dewey

Organizations: Image Analysis and Communications Laboratory, Johns Hopkins University · Department of Neurology, Johns Hopkins Hospital

Abstract

This work introduces MedForj, a suite of 3D foundational generative priors based on diffusion models. The MedForj models were trained on 72,65972{,}659 1~mm isotropic 3D T1T_1-weighted MRI human brain image volumes from 38,17438{,}174 subjects, drawn from a curated corpus of 80,67580{,}675 volumes from 42,50642{,}506 subjects spanning 3838 publicly available datasets. These training images were manually inspected to exclude those with poor quality and excessive pathology, and otherwise were minimally processed. The models include six different diffusion training strategies: rectified flow, latent diffusion rectified flow, flow matching, velocity prediction, clean prediction, and noise prediction. Image samples produced by each of these models were compared to each other and against real, ground truth data under downstream segmentation distributions, FID, five inverse problems, and blind human inspection in an observer study. Flow matching was the strongest strategy overall, achieving the best inverse problem solving results at 28.8028.80~dB PSNR and 0.8740.874 SSIM averaged over the five forward problems, the highest rate of reconstructions judged real by blind human raters at 72.6%72.6\%, and the closest per-structure match to real segmented anatomy in a permutation test. It was not best everywhere: rectified flow produced the most convincing unconditional samples in the observer study and the best FID, and the latent rectified-flow model achieved the smallest joint distributional distance to real anatomy. No other strategy, however, performed consistently well across all four evaluations. We therefore recommend flow matching as the default MedForj prior, while releasing every strategy so that the choice can be revisited per application. All model weights and corresponding code are publicly available at https://github.com/piksl-research/medforj.

Figures & tables

Explore similar work

Aug 5, 2026cs.CV

VoxStruct3D: Structure-Leading Flow Matching for Voxel-Space 3D MRI Synthesis

High-fidelity 3D MRI synthesis requires both globally coherent anatomy and fine-grained voxel-level detail. Although latent diffusion makes volumetric generation tractable, its image autoencoder introduces a reconstruction bottleneck that can limit the fine detail recoverable in the final volume. We present VoxStruct3D, a voxel-space flow-matching framework that directly models full-resolution MRI volumes using a clean-data prediction objective. Its Volumetric Voxel Generator (VVG) combines factorized 3D patch embedding with overlapping upsampling, time-modulated residual refinement, and skip fusion, enabling neighboring tokens to jointly reconstruct shared voxel regions and suppress patch-boundary artifacts. To complement direct voxel-space modeling with an explicit anatomical prior, we further introduce a Structure-First, Image-Follows (SFIF) strategy. A frozen pretrained 3D medical encoder and a StructVAE extract compact structure tokens that preserve dominant anatomy, while a structure-leading schedule keeps their trajectory ahead of the image trajectory. Patch-Aligned RoPE spatially aligns the unequal token grids, and asymmetric attention enforces one-way guidance from structure to image. Experiments on pathological and healthy T1-weighted brain MRI datasets show that VoxStruct3D achieves the strongest overall performance across feature-distribution alignment, sample diversity, and perceptual quality, producing anatomically coherent and visually realistic volumes.
Aug 10, 2026cs.CV

MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models

Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin (ΔΔPSNR <1<1,dB, ΔΔSSIM <0.02<0.02; paired TOST p=[[p]]p=[[p]]): mean PSNR is 27.3,dB vs. 27.0,dB and mean SSIM is 0.95 vs. 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The codebase is available at https://github.com/lisafis/MRIComp4Flow .
Aug 24, 2026cs.CV

AnaDiffusion: Anatomically CompositionalLatent Diffusion for Controllable 3D Brain MRI Generation

3D brain MRI generation has made significant advances in medical imaging, simulation, and controllable anatomical analysis. However, existing generative models typically synthesize 3D volumes monolithically, often overlooking regional anatomical structures and limiting local controllability. To address these limitations, we introduce AnaDiffusion, an anatomically compositional latent diffusion framework that factorizes the generation process into distinct, anatomically meaningful regions, followed by part-to-whole assembly and global refinement. Our approach first trains part diffusion models to capture local structural priors. We then inject an assembled anatomical composite of the parts into the whole-brain latent representation and continue denoising. This mechanism enables the model to resolve global context while preserving the injected anatomy. As a result, AnaDiffusion produces both explicit part assets and a globally coherent volume, thereby enabling controllable part editing without requiring subject-specific dense segmentation maps at inference time while maintaining consistent part-to-whole brain structure. On the subject-disjoint ADNI test split, AnaDiffusion achieves the lowest FID across the whole brain, left and right hemispheres, cerebellar-brainstem complex, and seam regions. It also achieves the best cerebellar and second-best ventricular and brainstem absolute Cohen's d values among the evaluated methods. In localized editing experiments, paired MS-SSIM demonstrates high target transfer and off-target preservation, supporting controllable part replacement with minimal unintended anatomical alterations.