cs.ROFeb 19, 2026

Proximal powered knee placement: a case study

Authors: Kyle R. Embry, Lorenzo Vianello, Jim Lipsey, Frank Ursetta, Michael Stephens, Zhi Wang, Ann M. Simon, Andrea J. Ikeda, 

Organizations: Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL, USA · Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, USA · Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA

Abstract

Lower limb amputation affects millions worldwide, leading to impaired mobility, reduced walking speed, and limited participation in daily and social activities. Powered prosthetic knees can partially restore mobility by actively assisting knee joint torque, improving gait symmetry, sit-to-stand transitions, and walking speed. However, added mass from powered components may diminish these benefits, negatively affecting gait mechanics and increasing metabolic cost. Consequently, optimizing mass distribution, rather than simply minimizing total mass, may provide a more effective and practical solution. In this exploratory study, we evaluated the feasibility of above-knee powertrain placement for a powered prosthetic knee in a small cohort. Compared to below-knee placement, the above-knee configuration demonstrated improved walking speed (+9.2% for one participant) and cadence (+3.6%), with mixed effects on gait symmetry. Kinematic measures indicated similar knee range of motion and peak velocity across configurations. Additional testing on ramps and stairs confirmed the robustness of the control strategy across multiple locomotion tasks. These preliminary findings suggest that above-knee placement is functionally feasible and that careful mass distribution can preserve the benefits of powered assistance while mitigating adverse effects of added weight. Further studies are needed to confirm these trends and guide design and clinical recommendations.

Figures & tables

Explore similar work

Sep 2, 2026

Design and Validation of a Lightweight, Low-Profile Powered Knee Prosthesis with Quasi-Direct Drive Actuation

Fully-powered knee prostheses, unlike traditional passive knees, can perform controlled positive work, reducing the need for compensatory behaviors by users during energy-intensive activities. While quasi-direct drive (QDD) actuators provide superior torque control, backdrivability, and acoustic noise properties compared to traditional highly-geared actuators, prior QDD prototypes have been too heavy and bulky for commercial translation. In this work, we present the design and validation of a new lightweight (2.6 kg) and low-profile (24.5 cm tip-to-tip build height) QDD knee prosthesis. By optimizing an 18 to 1 two-stage transmission alongside thermal and structural finite-element analyses, we significantly reduce device mass while enabling a peak torque of 145 Nm. Through benchtop tests, we validate the device's high output torque, low backdrive torque (1 Nm), and its precision position and torque control capabilities. We also demonstrate biomimetic kinematics and peak knee extension torques (within one standard deviation of able-bodied references) during both level-ground walking and sit-stand transitions performed by three participants with transfemoral amputation and varying K-levels. By meeting or improving upon the mass, build height, peak torque, and acoustic noise of a leading commercial powered knee, this work establishes the clinical viability of emerging QDD prostheses that promise improved dynamic performance for their users.
Oct 2, 2026

Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance Strategies

Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-based muscle strength scaling, were used in predictive simulations to generate gait at self-selected walking speeds. Ideal actuators were incorporated to simulate various combinations of joint assistance at peak levels of 25 Nm and 50 Nm to examine the effects of assistance on gait and metabolic savings. The effects of each assistance configuration were assessed through cost of transport (COT), joint kinematics, muscle activations, assistive torques, and joint-level power metrics to characterize the biomechanical and energetic impacts of different assistance strategies. At 50 Nm, combined H+K+A (hip-knee-ankle) assistance resulted in the greatest mean COT reduction of 48.50 +/- 4.55%, with individual reductions ranging from 42.22% to 54.65% across the subjects. Among single-joint conditions, assisting the hip was most effective, reducing COT by 31.77 +/- 5.21%; the knee and ankle produced smaller, comparable reductions (19.17% and 17.02%). H+A (hip-ankle) assistance (44.60 +/- 7.08%) emerged as the most effective two-joint assistive configuration. Increasing the torque bound increased positive assistive power primarily at the hip and ankle, while knee assistance showed little sensitivity and delivered positive power near pre-swing. These results support H+A assistance as an efficient two-actuator target, while identifying the knee's atypical pre-swing power strategy as a candidate for targeted experimental validation.
Jun 5, 2026

End-to-End Control of a Powered Knee-Ankle Prosthesis Towards Unified, Tuning-Free Assistance

Powered prostheses conventionally rely on impedance controllers that require extensive manual tuning and explicit mode classification. In this work, we present real-time deployment of an end-to-end prosthesis controller that estimates continuous actuator signals from onboard sensors, eliminating the need for intent classifiers and subject-specific tuning. Temporal Convolutional Networks were trained on a multi-terrain dataset from 18 individuals with transfemoral amputation and deployed in real time across five locomotion modes. Four participants (three able-bodied, one with transfemoral amputation) ambulated across level ground, ramp ascent and descent, and stair ascent and descent. During level walking, the deployed controller reproduced the training-data scaling of peak ankle torque with walking speed (deployed 0.85 Nm/kg per m/s, p = 0.001; training 0.96 Nm/kg per m/s, 95% CI [0.42, 1.50], p = 0.002), after excluding one outlier traced to atypical prosthesis loading. During ramp ascent, the controller scaled knee pre-flexion with grade (deployed 2.92 deg/deg, p = 0.027; training 3.30 deg/deg, 95% CI [1.83, 4.77], p < 0.001). During ramp descent, the controller increased resistive knee torque relative to level walking (deployed +0.16 Nm/kg, p < 0.001; training +0.16 Nm/kg, p = 0.008). Seamless stair transitions were generated for both intact- and prosthetic-side-leading sequences in ascent and descent, despite the training data containing only one limb-leading sequence. These results provide initial evidence towards end-to-end control that can provide unified, mode-adaptive prosthetic assistance without subject-specific tuning.