eess.SPFeb 23, 2026

The Sim-to-Real Gap in MRS Quantification: A Systematic Deep Learning Validation for GABA

Authors: Zien Ma, S. M. Shermer, Oktay Karakuş, Frank C. Langbein

Organizations: School of Computer Science and Informatics, Cardiff University, Cardiff, CF24 4AG, United Kingdom · Faculty of Science and Engineering, Swansea University, Swansea, SA2 8PP, United Kingdom

Abstract

Magnetic resonance spectroscopy (MRS) is used to quantify metabolites in vivo and estimate biomarkers for conditions ranging from neurological disorders to cancers. Quantifying low-concentration metabolites such as GABA (γγ-aminobutyric acid) is challenging due to low signal-to-noise ratio (SNR) and spectral overlap. We investigate and validate deep learning for quantifying complex, low-SNR, overlapping signals from MEGA-PRESS spectra, devise a convolutional neural network (CNN) and a Y-shaped autoencoder (YAE), and select the best models via Bayesian optimisation on 10,000 simulated spectra from slice-profile-aware MEGA-PRESS simulations. The selected models are trained on 100,000 simulated spectra. We validate their performance on 144 spectra from 112 experimental phantoms containing five metabolites of interest (GABA, Glu, Gln, NAA, Cr) with known ground truth concentrations across solution and gel series acquired at 3 T under varied bandwidths and implementations. These models are further assessed against the widely used LCModel quantification tool. On simulations, both models achieve near-perfect agreement (small MAEs; regression slopes ≈1.00\approx 1.00, R2≈1.00R^2 \approx 1.00). On experimental phantom data, errors initially increased substantially. However, modelling variable linewidths in the training data significantly reduced this gap. The best augmented deep learning models achieved a mean MAE for GABA over all phantom spectra of 0.151 (YAE) and 0.160 (FCNN) in max-normalised relative concentrations, outperforming the conventional baseline LCModel (0.220). A sim-to-real gap remains, but physics-informed data augmentation substantially reduced it. Phantom ground truth is needed to judge whether a method will perform reliably on real data.

Figures & tables

Explore similar work

CardsList
  1. Data-driven Synthesis of Magnetic Resonance Spectroscopy Data using a Variational Autoencoder

    Feb 28, 2026Dennis M. J. van de Sande, Julian P. Merkofer, Sina Amirrajab +4Synthetic Data GenerationSynthetic Data Evaluation

  2. HyperFitS -- Hypernetwork Fitting Spectra for metabolic quantification of 1{}^1H MR spectroscopic imaging

    Apr 3, 2026Paul J. Weiser, Gulnur Ungan, Amirmohammad Shamaei +5Magnetic Resonance ImagingHypernetworks

  3. Physics-Informed Sylvester Normalizing Flows for Bayesian Inference in Magnetic Resonance Spectroscopy

    May 6, 2025Julian P. Merkofer, Dennis M. J. van de Sande, Alex A. Bhogal +1Normalizing FlowsBayesian Inference