cs.CVFeb 24, 2026

Optimizing Occupancy Sensor Placement in Smart Environments

Authors: Hao Lu, Richard J. Radke

Abstract

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. The key to achieving this goal is being able to recognize zone occupancy in real time, without impeding occupants' activities or compromising privacy. While low-resolution, privacy-preserving time-of-flight (ToF) sensor networks have demonstrated good performance in zone counting, the performance depends on careful sensor placement. To address this issue, we propose an automatic sensor placement method that determines optimal sensor layouts for a given number of sensors, and can predict the counting accuracy of such a layout. In particular, given the geometric constraints of an office environment, we simulate a large number of occupant trajectories. We then formulate the sensor placement problem as an integer linear programming (ILP) problem and solve it with the branch and bound method. We demonstrate the effectiveness of the proposed method based on simulations of several different office environments.

Figures & tables

Explore similar work

Mar 27, 2026

Experimental study on surveillance video-based indoor occupancy measurement with occupant-centric control

Accurate occupancy information is essential for closed-loop occupant-centric control (OCC) in smart buildings. However, existing vision-based occupancy measurement methods often struggle to provide stable and accurate measurements in real indoor environments, and their implications for downstream HVAC control remain insufficiently studied. To achieve Net Zero emissions by 2050, this paper presents an experimental study of large language models (LLMs)-enhanced vision-based indoor occupancy measurement and its impact on OCC-enabled HVAC operation. Detection-only, tracking-based, and LLM-based refinement pipelines are compared under identical conditions using real surveillance data collected from a research laboratory in China, with frame-level manual ground-truth annotations. Results show that tracking-based methods improve temporal stability over detection-only measurement, while LLM-based refinement further improves occupancy measurement performance and reduces false unoccupied prediction. The best-performing pipeline, YOLOv8+DeepSeek, achieves an accuracy of 0.8824 and an F1-score of 0.9320. This pipeline is then integrated into an HVAC supervisory model predictive control framework in OpenStudio-EnergyPlus. Experimental results demonstrate that the proposed framework can support more efficient OCC operation, achieving a substantial HVAC energy-saving potential of 17.94%. These findings provide an effective methodology and practical foundation for future research in AI-enhanced smart building operations.
Jun 19, 2026

FLM-Occ: Feed-forward Likelihood Maximization for Efficient Indoor Occupancy Prediction

Recent indoor occupancy prediction methods adopt Gaussian primitives as a sparse 3D representation for computational efficiency. However, their training relies on voxel classification, which imposes only local constraints and lacks global supervision on the distribution of the primitives. Therefore, they inevitably predict spurious primitives in empty regions, undermining both representational and computational efficiency. To address this, we propose Feed-forward Likelihood Maximization (FLM), a novel framework that reformulates occupancy prediction as voxel distribution estimation. In FLM, a network is trained to predict a mixture model that maximizes the likelihood over ground-truth occupied voxels in a feed-forward manner. To enable end-to-end training of networks and voxelization of a standard mixture model, we define mixture weights as normalized primitive volumes to implicitly enforce simplex constraints and derive novel voxelization formulas. Based on FLM, our FLM-Occ, a novel method that is capable of relocating randomly initialized primitives over long distances to model a scene. On Occ-ScanNet, FLM-Occ achieves superior accuracy using only 32 superquadrics, 2.7% of the prior SoTA, while running 3.7 times faster.
Oct 8, 2026

Data-driven Optimal Sensor Placement for Aerosol Monitoring in the UK

We develop a data-driven sensor-placement framework and apply it to aerosol monitoring in the United Kingdom (UK). A trained convolutional Gaussian neural process is embedded within the DeepSensor optimisation framework. Genetic optimisation with lazy evaluation and caching reduces mean computational time by 60% (10±\pm3 versus 25±\pm7 minutes) while producing sequential placement performance comparable to the greedy solver. Using the CAMS reference field to construct a retrospective oracle benchmark, Joint NLL improves by about 22% for Joint-MI-driven genetic placement after five locations for aerosol stations are identified. Seasonal and wind-regime analyses show that agreement between model-based criteria and oracle benchmarks varies with meteorological transport conditions. These results show a computationally efficient approach for data-informed expansion of environmental observing systems.