eess.IVFeb 24, 2026

RelA-Diffusion: Relativistic Adversarial Diffusion for Multi-Tracer PET Synthesis from Multi-Sequence MRI

Authors: Minhui Yu, Yongheng Sun, David S. Lalush, Jason P Mihalik, Pew-Thian Yap, Mingxia Liu

Organizations: Department of Radiology and Biomedical Research Imaging Center (BRIC), University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA. · Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA. · Department of Exercise and Sport Science, UNC-CH, Chapel Hill, NC 27599, USA.

Abstract

Multi-tracer positron emission tomography (PET) provides critical insights into diverse neuropathological processes such as tau accumulation, neuroinflammation, and ββ-amyloid deposition in the brain, making it indispensable for comprehensive neurological assessment. However, routine acquisition of multi-tracer PET is limited by high costs, radiation exposure, and restricted tracer availability. Recent efforts have explored deep learning approaches for synthesizing PET images from structural MRI. While some methods rely solely on T1-weighted MRI, others incorporate additional sequences such as T2-FLAIR to improve pathological sensitivity. However, existing methods often struggle to capture fine-grained anatomical and pathological details, resulting in artifacts and unrealistic outputs. To this end, we propose RelA-Diffusion, a Relativistic Adversarial Diffusion framework for multi-tracer PET synthesis from multi-sequence MRI. By leveraging both T1-weighted and T2-FLAIR scans as complementary inputs, RelA-Diffusion captures richer structural information to guide image generation. To improve synthesis fidelity, we introduce a gradient-penalized relativistic adversarial loss to the intermediate clean predictions of the diffusion model. This loss compares real and generated images in a relative manner, encouraging the synthesis of more realistic local structures. Both the relativistic formulation and the gradient penalty contribute to stabilizing the training, while adversarial feedback at each diffusion timestep enables consistent refinement throughout the generation process. Extensive experiments on two datasets demonstrate that RelA-Diffusion outperforms existing methods in both visual fidelity and quantitative metrics, highlighting its potential for accurate synthesis of multi-tracer PET.

Figures & tables

Explore similar work

CardsList
  1. Precision Synthesis of Multi-Tracer PET via VLM-Modulated Rectified Flow for Stratifying Mild Cognitive Impairment

    Apr 13, 2026Tuo Liu, Shuijin Lin, Shaozhen Yan +4Medical Image SynthesisRectified Flow

  2. Translating MRI to PET through Conditional Diffusion Models with Enhanced Pathology Awareness

    Mar 19, 2026Yitong Li, Igor Yakushev, Dennis M. Hedderich +1Medical Image SynthesisImage-to-Image Translation