cs.CVMar 2, 2026

Zero-shot Low-Field MRI Enhancement via Diffusion-Based Adaptive Contrast Transport

Authors: Muyu Liu, Chenhe Du, Xuanyu Tian, Qing Wu, Xiao Wang, Haonan Zhang, Hongjiang Wei, Yuyao Zhang

Organizations: School of Information Science and Technology, ShanghaiTech University, Shanghai, China · School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China

Abstract

Low-field (LF) magnetic resonance imaging (MRI) democratizes access to diagnostic imaging but is fundamentally limited by low signal-to-noise ratio and significant tissue contrast distortion due to field-dependent relaxation dynamics. Reconstructing high-field (HF) quality images from LF data is a blind inverse problem, severely challenged by the scarcity of paired training data and the unknown, non-linear contrast transformation operator. Existing zero-shot methods, which assume simplified linear degradation, often fail to recover authentic tissue contrast. In this paper, we propose DACT(Diffusion-Based Adaptive Contrast Transport), a novel zero-shot framework that restores HF-quality images without paired supervision. DACT synergizes a pre-trained HF diffusion prior to ensure anatomical fidelity with a physically-informed adaptive forward model. Specifically, we introduce a differentiable Sinkhorn optimal transport module that explicitly models and corrects the intensity distribution shift between LF and HF domains during the reverse diffusion process. This allows the framework to dynamically learn the intractable contrast mapping while preserving topological consistency. Extensive experiments on simulated and real clinical LF datasets demonstrate that DACT achieves state-of-the-art performance, yielding reconstructions with superior structural detail and correct tissue contrast.

Figures & tables

Explore similar work

Mar 11, 2026

ReDiff: Reliability-Guided Diffusion for Trustworthy Ultra-Low-Field to High-Field MRI Synthesis

Low-field to high-field MRI synthesis has emerged as a promising strategy to improve image quality when access to high-field scanners is limited. However, in ultra-low-field settings, the degradation of anatomical detail is spatially heterogeneous: structurally ambiguous regions are more susceptible to unstable high-frequency generation, which may produce anatomically inconsistent textures and boundaries. This issue is particularly problematic when synthesized images are used for downstream quantitative analysis. We therefore study how to make diffusion-based LF-to-HF synthesis more spatially reliable, rather than only sharper on average. To this end, we propose a reliability-guided diffusion framework (ReDiff) with two complementary inference-time mechanisms. First, a reliability-guided sampling strategy attenuates unstable reverse-diffusion updates in regions with weak low-field support. Second, an uncertainty-aware candidate selection scheme aggregates multiple stochastic reconstructions according to spatial consensus and predictive uncertainty. Beyond aggregate image quality, we test whether the uncertainty is itself a usable reliability signal. Experiments on paired 64mT→\rightarrow3T MRI datasets show that ReDiff attains the lowest LPIPS across three contrasts and two datasets while remaining competitive on PSNR and SSIM, and downstream segmentation analysis indicates better preservation of anatomical structure.
Mar 26, 2026

Subject-Specific Low-Field MRI Synthesis via a Neural Operator

Low-field (LF) magnetic resonance imaging (MRI) improves accessibility and reduces costs but generally has lower signal-to-noise ratios and degraded contrast compared to high field (HF) MRI, limiting its clinical utility. Simulating LF MRI from HF MRI enables virtual evaluation of novel imaging devices and development of LF algorithms. Existing low field simulators rely on noise injection and smoothing, which fail to capture the contrast degradation seen in LF acquisitions. To this end, we introduce an end-to-end LF-MRI synthesis framework that learns HF to LF image degradation directly from a small number of paired HF-LF MRIs. Specifically, we introduce a novel HF to LF coordinate-image decoupled neural operator (H2LO) to model the underlying degradation process, and tailor it to capture high-frequency noise textures and image structure. Experimental results in T1w and T2w MRI demonstrate that H2LO produces more faithful simulated low-field images than existing parameterized noise synthesis models and popular image-to-image translation models. Furthermore, it improves performance in downstream image enhancement tasks, showcasing its potential to enhance LF MRI diagnostic capabilities.
May 27, 2026

Enhancing Ultra-low-field MRI with Segmentation-guided Adversarial Learning

Ultra-low-field (ULF) MRI offers portable and low-cost imaging but suffers from poor image quality. To address this, we present our submission to the 2025 ULF Enhancement Challenge (ULF-EnC), where the goal is to synthesise high-field-like MRIs from 64 mT scans. Our pipeline enhances ULF MRI through a combination of anatomical conditioning and model ensembling. We first generate tissue segmentation priors using a Swin UNETR trained solely on challenge-provided data. These priors condition two independent enhancement networks - a CycleGAN and a transformer-based residual enhancement model (T-REX) - each trained to synthesise 3 T-like MRIs. Outputs from both models are combined using a weighted average. Our approach produces enhanced MRIs that were comparable to high-field scans both quantitatively and qualitatively.