MedQ-Deg: A Multidimensional Benchmark for Evaluating MLLMs Across Medical Image Quality Degradations
Authors: Jiyao Liu, Junzhi Ning, Chenglong Ma, Wanying Qu, Jianghan Shen, Siqi Luo, Jinjie Wei, Jin Ye, +9 more
Organizations: Fudan University, Shanghai, China · Shanghai AI Lab, Shanghai, China · Shanghai Jiaotong University, Shanghai, China · Imperial College London, London, UK
Despite impressive performance on standard benchmarks, multimodal large language models (MLLMs) face critical challenges in real-world clinical environments where medical images inevitably suffer various quality degradations. Existing benchmarks exhibit two key limitations: (1) absence of large-scale, multidimensional assessment across medical image quality gradients and (2) no systematic confidence calibration analysis. To address these gaps, we present MedQ-Deg, a comprehensive benchmark for evaluating medical MLLMs under image quality degradations. MedQ-Deg provides multi-dimensional evaluation spanning 18 distinct degradation types, 30 fine-grained capability dimensions, and 7 imaging modalities, with 24,894 question-answer pairs. Each degradation is implemented at 3 severity degrees, calibrated by expert radiologists. We further introduce Calibration Shift metric, which quantifies the gap between a model's perceived confidence and actual performance to assess metacognitive reliability under degradation. Our comprehensive evaluation of 40 mainstream MLLMs reveals several critical findings: (1) overall model performance degrades systematically as degradation severity increases, (2) models universally exhibit the AI Dunning-Kruger Effect, maintaining inappropriately high confidence despite severe accuracy collapse, and (3) models display markedly differentiated behavioral patterns across capability dimensions, imaging modalities, and degradation types. We hope MedQ-Deg drives progress toward medical MLLMs that are robust and trustworthy in real clinical practice.
Figures & tables
Figure 1: Illustration of AI Dunning-Kruger Effect. An MLLM correctly identifies a liver lesion in the clean CT image but yields erroneous predictions with similarly high confidence when the image is corrupted while the lesion is still visible.
Benchmark
Publication
Total QA
#Modality
#Capability
#Degrad.
MedMNIST-C [ 11 ]
Arxiv 2024
520k (train & eval.)
9
1 (classification)
17
RobustMedCLIP [ 17 ]
MIUA 2025
137k (train & eval.)
5
1 (classification)
7
Pathology Corruptions [ 51 ]
MICCAI 2022
327k (train & eval.)
1
1 (classification)
9
ROOD-MRI [ 5 ]
NeuroImage 2023
1,475 (eval.)
1
1 (segmentation)
11
VLM Artefacts [ 8 ]
npj Digit. Med. 2025
6,600 (eval.)
3
1 (detection)
5
RobustMed-Bench [ 46 ]
Arxiv 2025
1,500 (eval.)
3
–
6
Table 1: Comparison with related benchmarks. “–” indicates the information is not reported in the original publication.
Figure 2: Overview of the MedQ-Deg benchmark framework. Two orthogonal hierarchies structure the evaluation: a capability hierarchy (left) decomposing clinical competence into 30 fine-grained skills across 6 tasks, and a degradation hierarchy (right) covering 18 degradation types across 7 modalities. The data pipeline (middle) applies each degradation at three expert-calibrated severity degrees (L0–L2).
Figure 3: Model performance across medical image quality degradation. Accuracy of 40 MLLMs evaluated at three severity degrees (L0–L2). X-axis labels are colored by model category: blue for open-source general models, brown for commercial MLLMs, and purple for medical-specialized models.
Medical Perception
Clinical Reasoning
Model
Avg.
CU
IP
AR
BS
Diag.
Treat.
Commercial MLLMs
GPT-5
64.5 ( ↓ 3.5)
67.2 ( ↓ 4.3)
36.5 ( ↓ 0.9)
67.4 ( ↓ 4.4)
75.0 ( ↓ 6.0)
62.1 ( ↓ 2.9)
78.8 ( ↓ 2.3)
Gemini-2.5-Pro
58.2 ( ↓ 3.8)
66.9 ( ↓ 3.4)
30.0 ( ↓ 6.5)
72.0 ( ↓ 5.7)
60.7 ( ↓ 8.3)
60.1 ( ↓ 1.3)
59.6 ( ↑ 2.6)
Gemini-2.5-Flash
50.7 ( ↓ 2.9)
63.6 ( ↓ 4.8)
25.5 ( ↓ 1.2)
71.2 ( ↑ 0.1)
58.9 ( ↓ 5.7)
38.9 ( ↓ 3.2)
46.1 ( ↓ 2.8)
GPT-5.1
49.6 ( ↓ 5.9)
65.9 ( ↓ 3.3)
30.5 ( ↓ 6.0)
65.8 ( ↓ 4.2)
50.0 ( ↓ 9.5)
47.0 ( ↓ 8.5)
38.5 ( ↓ 3.9)
Table 2: Capability-level performance (L1&L2) with degradation magnitude. Average accuracy across the mid-level capability dimensions, computed over L1 and L2 degradations. Numbers in parentheses show performance drop from L0 to L1&L2. “CU”: Clinical Understanding. “IP”: Imaging Perception. “AR”: Anatomical Recognition. “BS”: Basic Science. “Diag.”: Diagnosis. “Treat.”: Treatment.
Model
Avg.
Intensity
Noise
R&B
Artifacts
Motion
Commercial MLLMs
Gemini-2.5-Pro
68.2 ( ↓ 3.7)
71.1 ( ↓ 0.9)
69.2 ( ↓ 2.3)
67.2 ( ↓ 2.0)
65.1 ( ↓ 5.3)
68.6 ( ↓ 8.0)
GPT-5
67.5 ( ↓ 4.2)
72.2 ( ↓ 4.0)
66.2 ( ↓ 3.2)
67.5 ( ↓ 2.5)
63.1 ( ↓ 6.4)
68.4 ( ↓ 4.8)
GPT-5.1
65.7 ( ↓ 4.2)
70.9 ( ↓ 2.5)
64.2 ( ↓ 4.8)
65.7 ( ↓ 4.2)
60.5 ( ↓ 6.2)
67.2 ( ↓ 3.4)
Gemini-2.5-Flash
65.4 ( ↓ 2.5)
67.5 ( ↓ 0.6)
65.1 ( ↓ 1.8)
64.8 ( ↓ 1.0)
60.7 ( ↓ 5.0)
68.7 ( ↓ 4.0)
GPT-4.1
65.0 ( ↓ 2.1)
69.4 ( ↓ 3.7)
62.7 ( ↓ 0.8)
65.1 ( ↓ 2.4)
60.6 ( ↓ 3.2)
67.4 ( ↓ 0.6)
Table 3: Degradation-category performance (L1&L2) with degradation magnitude. Average accuracy across five degradation categories, computed over L1 and L2 degradations. Numbers in parentheses show performance drop from L0 to L1&L2. “R&B”: resolution and blur issues.
Figure 4: Comprehensive analysis of model calibration shift across severity degrees. These panels quantify the widening gap between actual accuracy and model certainty under increasing image degradation. As degradation scales from L0 to L2, the stability of perceived performance against collapsing accuracy reveals a fundamental failure in metacognitive awareness across MLLMs.
Figure 5: Simulated vs. Real-World Evaluation Consistency. Left: t-SNE projection of BiomedCLIP features from simulated and real degraded images. Real and simulated images co-locate within each modality cluster, confirming distribution alignment. Right: Bump chart tracing per-model ranks across Simulated-Mild, Simulated-Severe, Real-World-Mild, and Real-World-Severe conditions.
Appendix figures & tables9 assets
Supplementary material from the paper’s appendix.
Appendix
Figure 6: Expert annotation interface.
Fine-grained Capability
Mid-level Capability
Count
Ratio in Mid-level
Ratio in Total
Disease Diagnosis
Clinical Understanding
12,908
97.74%
62.70%
Severity Grading
Clinical Understanding
138
1.04%
0.67%
Basic Science Understanding
Clinical Understanding
78
0.59%
0.38%
Lesion Grading
Clinical Understanding
68
0.51%
0.33%
Attribute Recognition
Clinical Understanding
10
0.08%
0.05%
Treatment-Understanding
Clinical Understanding
4
0.03%
0.02%
Appendix
Table 4: Capability hierarchy of MedQ-Deg. Row shading indicates high-level capability: blue rows belong to Medical Perception and purple rows belong to Clinical Reasoning .
Name
Parent Category
Count
Ratio in Parent
Ratio in Total
Modality
Artifacts
-
5,322
-
25.85%
All
limited_angle
Artifacts
1,440
27.06%
6.99%
CT
sparse_view
Artifacts
1,440
27.06%
6.99%
CT
bias_field_artifact
Artifacts
936
17.59%
4.55%
MRI
undersampling_artifact
Artifacts
672
12.63%
3.26%
MRI
ghosting_artifact
Artifacts
352
6.61%
1.71%
MRI
Appendix
Table 5: Degradation type statistics.
Model
L0 ↑
L1 ↑
L2 ↑
L1-L0 ↓
L2-L0 ↓
Commercial MLLMs
Gemini-2.5-Pro
71.39
69.93
65.20
-1.46
-6.19
GPT-5
70.27
69.09
64.30
-1.18
-5.97
GPT-5.1
68.56
67.34
62.16
-1.22
-6.40
Gemini-2.5-Flash
67.39
67.18
62.00
-0.21
-5.39
GPT-4o
66.98
65.22
59.73
-1.76
-7.25
Appendix
Table 6: Overall accuracy across severity degrees. L0/L1/L2 accuracies and drops (L1-L0, L2-L0).
Figure 7: Performance comparison across seven medical imaging modalities under three severity degrees. Each radar chart shows model performance for a specific modality.
Figure 8: Accuracy difference heatmaps (L0 − Degraded). Red : degradation hurts accuracy; green : no effect or slight gain; white: no change. (a) L0 vs. L1 by degradation type. (b) L0 vs. L2 by degradation type. (c) L0 vs. L1 by fine-grained capability. (d) L0 vs. L2 by fine-grained capability.
Figure 9: Degradation examples (Part 1/3): CT and MRI modalities.
The rise of multimodal large language models (MLLMs) has sparked an unprecedented wave of applications in the field of medical imaging analysis. However, as one of the earliest and most fundamental tasks integrated into this paradigm, medical image classification reveals a sobering reality: state-of-the-art medical MLLMs consistently underperform compared to traditional deep learning models, despite their overwhelming advantages in pre-training data and model parameters. This paradox prompts a critical rethinking: where exactly does the performance degradation originate? In this paper, we conduct extensive experiments on 14 open-source medical MLLMs across three representative image classification datasets. Moving beyond superficial performance benchmarking, we employ feature probing to track the information flow of visual features module-by-module and layer-by-layer throughout the entire MLLM pipeline, enabling explicit visualization of where and how classification signals are distorted, diluted, or overridden. As the first attempt to dissect classification performance degradation in medical MLLMs, our findings reveal four failure modes: 1) quality limitation in visual representation, 2) fidelity loss in connector projection, 3) comprehension deficit in LLM reasoning, and 4) misalignment of semantic mapping. Meanwhile, we introduce quantitative scores that characterize the healthiness of feature evolution, enabling principled comparisons across diverse MLLMs and datasets. Furthermore, we provide insightful discussions centered on the critical barriers that prevent current medical MLLMs from fulfilling their promised clinical potential. We hope that our work provokes rethinking within the community-highlighting that the road from high expectations to clinically deployable MLLMs remains long and winding.
Xun Zhu, Fanbin Mo, Xi Chen +6
Department of Electronic Engineering Tsinghua University Beijing, China · School of Artificial Intelligence BUPT Beijing, China · College of AI Tsinghua University Beijing, China +1
The potential of Multimodal Large Language Models (MLLMs) in domain of medical imaging raise the demands of systematic and rigorous evaluation frameworks that are aligned with the real-world medical imaging practice. Existing practices that report single or coarse-grained metrics are lack the granularity required for specialized clinical support and fail to assess the reliability of reasoning mechanisms. To address this, we propose a paradigm shift toward multidimensional, fine-grained and in-depth evaluation. Based on a two-stage systematic construction pipeline designed for this paradigm, we instantiate it with MedRCube. We benchmark 33 MLLMs, Lingshu-32B achieve top-tier performance. Crucially, MedRCube exposes a series of pronounced insights inaccessible under prior evaluation settings. Furthermore, we introduce a credibility evaluation subset to quantify reasoning credibility, uncover a highly significant positive association between shortcut behavior and diagnostic task performance, raising concerns for clinically trustworthy deployment. The resources of this work can be found at https://github.com/F1mc/MedRCube.
Zhijie Bao, Fangke Chen, Licheng Bao +4
School of Data Science, Fudan University, China · Shanghai Innovation Institute, China · School of Integrated Circuits, Zhejiang University, China +2
Vision-Language Models (VLMs) are increasingly applied in medical tasks such as pathology description, report generation, and visual question answering. Medical Image Quality Assessment (MIQA) supports diagnostic accuracy and patient safety by determining whether images meet the standards required for clinical decision-making. Automating MIQA with VLMs may reduce workload, but their behavior under real-world conditions, where images may be degraded or textual context may affect judgments, should be further explored before deployment. We benchmark VLMs on medical image quality using the MediMeta-C dataset zero-shot across seven corruption types and five severity levels. We evaluate sensitivity to degradation patterns, the effect of corruptions on embedding geometry, and whether textual attributes (demographics, expertise, infrastructure, institution) alter scores. Across 16 VLMs and seven modalities, pixelation produced the largest score reductions (mean -20.58%, up to -34.4% for OCT), whereas brightness had limited effect (-0.81%). Embedding displacement was associated with score changes. Same-family models showed correlations of 0.67-0.83; some produced increases up to +31% for corrupted mammography. Textual attributes affected scores: institutional prestige raised them +17.15%, and equipment age lowered them -14.7%. The largest changes were +95.62% (InternVL-8B) and -37.7% (MedGemma). Current VLMs show limitations for medical image quality assessment. Pixelation, a privacy-preserving transformation, reduces performance, indicating a trade-off between patient privacy and reliability. Sensitivity to contextual metadata indicates limited objectivity and marks metadata as a privacy and bias source. Privacy protection and objective quality assessment are related requirements for use.
Sofiane Ouaari, Kevin Vorwalder, Nico Pfeifer
Methods in Medical Informatics, Department of Computer Science, University of Tuebingen, Germany. · Institute for Bioinformatics and Medical Informatics (IBMI), University of Tuebingen, Germany.