cs.CVMar 10, 2026

FetalAgents: A Multi-Agent System for Fetal Ultrasound Image and Video Analysis

Authors: Xiaotian Hu, Junwei Huang, Mingxuan Liu, Kasidit Anmahapong, Yifei Chen, Yitong Luo, Yiming Huang, Xuguang Bai, 

Organizations: Tsinghua University, Beijing, China · University of California San Diego, La Jolla, CA, USA · West China Second University Hospital, Sichuan University, Chengdu, China

Abstract

Fetal ultrasound (US) is the primary imaging modality for prenatal screening, yet its interpretation relies heavily on the expertise of the clinician. Despite advances in deep learning and foundation models, existing automated tools for fetal US analysis struggle to balance task-specific accuracy with the whole-process versatility required to support end-to-end clinical workflows. To address these limitations, we propose FetalAgents, the first multi-agent system for comprehensive fetal US analysis. Through a lightweight, agentic coordination framework, FetalAgents dynamically orchestrates specialized vision experts to maximize performance across diagnosis, measurement, and segmentation. Furthermore, FetalAgents advances beyond static image analysis by supporting end-to-end video stream summarization, where keyframes are automatically identified across multiple anatomical planes, analyzed by coordinated experts, and synthesized with patient metadata into a structured clinical report. Extensive multi-center external evaluations across eight clinical tasks demonstrate that FetalAgents consistently delivers the most robust and accurate performance when compared against specialized models and multimodal large language models (MLLMs), ultimately providing an auditable, workflow-aligned solution for fetal ultrasound analysis and reporting.

Figures & tables

Explore similar work

May 25, 2026

Towards Reliable Fetal Ultrasound Interpretation with Multi-Agent Collaboration

Automated fetal ultrasound interpretation requires a workflow from visual perception, including plane recognition and anatomical segmentation, to clinical understanding, including biometric measurement and diagnostic reporting. However, the prevailing "one-task, one-model" paradigm limits systematic integration of evidence across this multi-step process. Although multimodal large language models (MLLMs) show promising visual understanding, their limited domain-specific grounding and hallucination risks restrict reliability in fetal ultrasound analysis. To address these limitations, we propose FetUSAgents, a tool-augmented multi-agent system for comprehensive fetal ultrasound interpretation, supporting visual question answering (VQA), report generation, image captioning, and video summarization. FetUSAgents coordinates task-specific visual tools through collaborative LLM agents and decomposes clinical queries into subtasks that progress from anatomical recognition to quantitative measurement. We further introduce Dual-Path Evidence Arbitration (DPEA), which integrates LLM-based deliberative reasoning with structured computational evidence from specialized visual tools. A retrieval-enhanced evidence bank consolidates intermediate findings to support traceable and clinically grounded conclusions. In addition, we construct FetUS-VQA, a dedicated VQA benchmark for fetal ultrasound, comprising 1,892 images and 3,205 question-answer pairs across 10 clinical tasks. Extensive out-of-distribution experiments show that FetUSAgents outperforms general and medical MLLMs, exceeding the strongest baseline by more than 25 percent in VQA accuracy. These results suggest a scalable route toward evidence-driven clinical assistants for prenatal imaging. Code is available.
Jun 9, 2026

FADA: Accessible fetal ultrasound interpretation and annotation with a selectively distilled unified vision-language model

A global shortage of trained sonographers limits prenatal ultrasound screening in low- and middle-income countries, where over half of pregnant women receive no skilled sonography. Current deep learning approaches address detection, segmentation, or classification in isolation, each demanding a separate model and expert-specified labels at inference. We present FADA, a unified vision-language model built on Qwen3.5-VL that performs clinical interpretation, classification, detection, and segmentation through a single interpretation-first pipeline without external labels. FADA distills knowledge from four domain-specific foundation models (FetalCLIP, UltraSAM, USF-MAE, UltraFedFM) via offline pre-computed feature caching. Selective distillation, which applies feature alignment only to annotation tasks while interpretation relies on standard fine-tuning, consistently outperforms full distillation across most evaluation axes. The recommended variant, FADA-SKD, achieves 0.8820 mean Dice for segmentation, 0.7671 [email protected] for detection, and 100% structured interpretation compliance. Expert sonographer validation across 237 images confirms clinically acceptable outputs in both autonomous and human-in-the-loop modes, with 73.5% of interpretations scoring perfectly under clinician guidance. The system is trainable on a single consumer GPU and deployable without cloud connectivity. We validate edge deployment by running the compressed 0.8B model on a commodity smartphone (Qualcomm Snapdragon 7 Gen 1, 12 GB RAM) using llama.cpp with GGUF quantization, completing the full 5-phase pipeline in approximately 60 seconds entirely offline. This establishes a practical pathway for integrating AI-assisted fetal assessment with portable ultrasound devices, directly addressing diagnostic access gaps in resource-constrained settings. Code, models, and data are available at https://github.com/mahmoodphd/FADA.
Apr 18, 2026

Unified Ultrasound Intelligence Toward an End-to-End Agentic System

Clinical ultrasound analysis demands models that generalize across heterogeneous organs, views, and devices, while supporting interpretable workflow-level analysis. Existing methods often rely on task-wise adaptation, and joint learning may be unstable due to cross-task interference, making it hard to deliver workflow-level outputs in practice. To address these challenges, we present USTri, a tri-stage ultrasound intelligence pipeline for unified multi-organ, multi-task analysis. Stage I trains a universal generalist USGen on different domains to learn broad, transferable priors that are robust to device and protocol variability. To better handle domain shifts and reach task-aligned performance while preserving ultrasound shared knowledge, Stage II builds USpec by keeping USGen frozen and finetuning dataset-specific heads. Stage III introduces USAgent, which mimics clinician workflows by orchestrating USpec specialists for multi-step inference and deterministic structured reports. On the FMC_UIA validation set, our model achieves the best overall performance across 4 task types and 27 datasets, outperforming state-of-the-art methods. Moreover, qualitative results show that USAgent produces clinically structured reports with high accuracy and interpretability. Our study suggests a scalable path to ultrasound intelligence that generalizes across heterogeneous ultrasound tasks and supports consistent end-to-end clinical workflows. The code is publicly available at: https://github.com/MacDunno/USTri.