eess.IVMar 13, 2026

MGMAR: Metal-Guided Metal Artifact Reduction for X-ray Computed Tomography

Authors: Hyoung Suk Park, Kiwan Jeon

Organizations: National Institute for Mathematical Sciences, Daejeon, 34047, Republic of Korea

Abstract

An X-ray computed tomography (CT), metal artifact reduction (MAR) remains a major challenge because metallic implants violate standard CT forward-model assumptions, producing severe streaking and shadowing artifacts that degrade diagnostic quality. We propose MGMAR, a metal-guided MAR method that explicitly leverages metal-related information throughout the reconstruction pipeline. MGMAR first generates a high-quality prior image by training a conditioned implicit neural representation (INR) using metal-unaffected projections, and then incorporates this prior into a normalized MAR (NMAR) framework for projection completion. To improve robustness under severe metal corruption, we pretrain the encoder-conditioned INR on paired metal-corrupted and artifact-free CT images, thereby embedding data-driven prior knowledge into the INR parameter space. This prior-embedded initialization reduces sensitivity to random initialization and accelerates convergence during measurement-specific refinement. The encoder takes a metal-corrupted reconstruction together with a recursively constructed metal artifact image, enabling the latent field to capture metal-dependent global artifact patterns. After projection completion using the INR prior, we further suppress residual artifacts using a metal-conditioned correction network, where the metal mask modulates intermediate features via adaptive instance normalization to target metal-dependent secondary artifacts while preserving anatomical structures. Experiments on the public AAPM-MAR benchmark demonstrate that MGMAR achieves state-of-the-art performance, attaining an average final score of 0.89 on 29 clinical test cases.

Figures & tables

Explore similar work

May 17, 2026

GraphMAR: Geometry-Aware Graph Learning Framework for Spatially Adaptive CT Metal Artifact Reduction

Computed tomography (CT) metal artifact reduction (MAR) aims to reduce the severe streaking artifacts induced by metallic implants and other high-density objects. Effective MAR generally requires both accurate artifact localization and artifact removal. Sinogram-domain methods can exploit explicit geometric cues, such as metal traces, to identify metal-corrupted measurements, while requiring raw projection data, which is often unavailable in clinical and practical scenarios. Image-domain methods are more flexible and widely applicable, yet they usually lack comparable geometric guidance, limiting their ability to localize artifacts and leading to suboptimal results. To address this limitation, we propose GraphMAR, a geometry-aware learning framework for explicit artifact identification and spatially adaptive MAR in the image domain. The key idea is to introduce graph-based geometric modeling as an image-domain analogue of sinogram metal traces. Specifically, we first construct a geometric graph from the metal mask and derive a geometric density graph that coarsely localizes artifact-prone regions according to inter-implant geometry. We then design GraphMoE, a graph-routed mixture-of-experts module that builds a polar-coordinate artifact graph in feature space and adaptively routes different experts to different spatial regions for MAR. By aligning the learned routing maps with the geometric density graph, GraphMAR provides explicit and interpretable artifact localization while enabling region-adaptive artifact reduction. Experiments on both simulated and real-world datasets demonstrate that GraphMAR achieves superior MAR performance compared with existing methods. To the best of our knowledge, this is the first work to introduce graph-based modeling for CT MAR and to enable explicit artifact identification in the image domain, improving both restoration quality and interpretability.
Jul 30, 2026

SCMA: Structure-Conditioned and Metal-Aware Flow Matching for CT Metal Artifact Reduction

In X-ray CT, metallic objects cause beam hardening, photon starvation, and scattering, leading to projection inconsistency, streaks, dark bands, and structural distortions that compromise clinical diagnosis and quantitative analysis. Existing metal artifact reduction (MAR) methods remain limited: optimization-based methods may leave residual artifacts or blur structures, regression networks may generalize poorly across scenarios, and generative models without sample-specific structural guidance and physical constraints may produce anatomically inconsistent structures. Flow Matching learns a continuous-time velocity field that deterministically transports a source distribution to a target distribution, providing a flexible MAR prior. However, standard unconditional Flow Matching does not exploit sample-specific structure, spatially nonuniform metal-induced degradation, or measured projections. To address these limitations, we propose SCMA, a structure-conditioned and metal-aware Flow Matching framework. First, a linear-interpolation-corrected image is fed into the velocity network with the intermediate state as a sample-specific structural condition, guiding inference toward artifact-free CT images while preserving anatomy. Second, time-varying spatial weights from the metal mask and its distance transform are incorporated into the Flow Matching loss to emphasize severe degradation within and around metal regions. Finally, conditional Flow Matching updates alternate with projection-consistency correction during inference, allowing reliable measurements outside metal traces to constrain predictions. Experiments on simulated and real CT data demonstrate that SCMA more effectively suppresses metal artifacts, preserves local anatomical structures, and reduces hallucination-like structures inconsistent with projection measurements than representative MAR methods.
Apr 8, 2026

Balancing Efficiency and Restoration: Lightweight Mamba-Based Model for CT Metal Artifact Reduction

In computed tomography imaging, metal implants frequently generate severe artifacts that compromise image quality and hinder diagnostic accuracy. There are three main challenges in the existing methods: the deterioration of organ and tissue structures, dependence on sinogram data, and an imbalance between resource use and restoration efficiency. Addressing these issues, we introduce MARMamba, which effectively eliminates artifacts caused by metals of different sizes while maintaining the integrity of the original anatomical structures of the image. Furthermore, this model only focuses on CT images affected by metal artifacts, thus negating the requirement for additional input data. The model is a streamlined UNet architecture, which incorporates multi-scale Mamba (MS-Mamba) as its core module. Within MS-Mamba, a flip mamba block captures comprehensive contextual information by analyzing images from multiple orientations. Subsequently, the average maximum feed-forward network integrates critical features with average features to suppress the artifacts. This combination allows MARMamba to reduce artifacts efficiently. The experimental results demonstrate that our model excels in reducing metal artifacts, offering distinct advantages over other models. It also strikes an optimal balance between computational demands, memory usage, and the number of parameters, highlighting its practical utility in the real world. The code of the presented model is available at: https://github.com/RICKand-MORTY/MARMamba.