A Systematic Benchmark of GAN Architectures for MRI-to-CT Synthesis
Organizations: Unit of Artificial Intelligence and Computer Systems, Department of Engineering, Università Campus Bio-Medico di Roma, Italy · CDI Centro Diagnostico Italiano S.p.A., Milan, Italy · University of Milan-Bicocca, Milan, Italy · Department of Diagnostics and Intervention, Biomedical Engineering and Radiation Physics, Umeå University, Umeå, Sweden
Abstract
The translation from Magnetic resonance imaging (MRI) to Computed tomography (CT) has been proposed as an effective solution to facilitate MRI-only clinical workflows while limiting exposure to ionizing radiation. Although numerous Generative Adversarial Network (GAN) architectures have been proposed for MRI-to-CT translation, systematic and fair comparisons across heterogeneous models remain limited. We present a comprehensive benchmark of ten GAN architectures evaluated on the SynthRAD2025 dataset across three anatomical districts (abdomen, thorax, head-and-neck). All models were trained under a unified validation protocol with identical preprocessing and optimization settings. Performance was assessed using complementary metrics capturing voxel-wise accuracy, structural fidelity, perceptual quality, and distribution-level realism, alongside an analysis of computational complexity. Supervised Paired models consistently outperformed Unpaired approaches, confirming the importance of voxel-wise supervision. Pix2Pix achieved the most balanced performance across districts while maintaining a favorable quality-to-complexity trade-off. Multi-district training improved structural robustness, whereas intra-district training maximized voxel-wise fidelity. This benchmark provides quantitative and computational guidance for model selection in MRI-only radiotherapy workflows and establishes a reproducible framework for future comparative studies. To ensure the reproducibility of our experiments we make our code public, together with the overall results, at the following link:https://github.com/arco-group/MRI_TO_CT.git
Figures & tables
| Configuration | Best Model | Mean Rank | Best Metrics |
| Best performing model per anatomical district | |||
| AB | UNIT | 2.00 | VIF, LPIPS |
| HN | Pix2Pix | 2.17 | PSNR, VIF, SSIM |
| TH | UNIT | 2.33 | VIF |
| ALL AB | Pix2Pix | 1.67 | MSE, PSNR, VIF, SSIM, LPIPS |
| ALL HN | Pix2Pix | 2.00 | VIF, SSIM, LPIPS |
| Configuration | Mean Rank | Best Metrics |
| Across aggregated anatomical settings | ||
| ALL AB+ALL HN+ALL TH | 1.67 | VIF, SSIM, LPIPS |
| ALL | 2.00 | FID |
| AB+HN+TH | 2.33 | MSE, PSNR |
| Across anatomical districts | ||
| TH | 1.83 | MSE, PSNR, VIF |