cs.CVMar 13, 2026

A Systematic Benchmark of GAN Architectures for MRI-to-CT Synthesis

Authors: Alessandro Pesci, Valerio Guarrasi, Marco Alì, Isabella Castiglioni, Paolo Soda

Organizations: Unit of Artificial Intelligence and Computer Systems, Department of Engineering, Università Campus Bio-Medico di Roma, Italy · CDI Centro Diagnostico Italiano S.p.A., Milan, Italy · University of Milan-Bicocca, Milan, Italy · Department of Diagnostics and Intervention, Biomedical Engineering and Radiation Physics, Umeå University, Umeå, Sweden

Abstract

The translation from Magnetic resonance imaging (MRI) to Computed tomography (CT) has been proposed as an effective solution to facilitate MRI-only clinical workflows while limiting exposure to ionizing radiation. Although numerous Generative Adversarial Network (GAN) architectures have been proposed for MRI-to-CT translation, systematic and fair comparisons across heterogeneous models remain limited. We present a comprehensive benchmark of ten GAN architectures evaluated on the SynthRAD2025 dataset across three anatomical districts (abdomen, thorax, head-and-neck). All models were trained under a unified validation protocol with identical preprocessing and optimization settings. Performance was assessed using complementary metrics capturing voxel-wise accuracy, structural fidelity, perceptual quality, and distribution-level realism, alongside an analysis of computational complexity. Supervised Paired models consistently outperformed Unpaired approaches, confirming the importance of voxel-wise supervision. Pix2Pix achieved the most balanced performance across districts while maintaining a favorable quality-to-complexity trade-off. Multi-district training improved structural robustness, whereas intra-district training maximized voxel-wise fidelity. This benchmark provides quantitative and computational guidance for model selection in MRI-only radiotherapy workflows and establishes a reproducible framework for future comparative studies. To ensure the reproducibility of our experiments we make our code public, together with the overall results, at the following link:https://github.com/arco-group/MRI_TO_CT.git

Figures & tables

Explore similar work

May 13, 2026

Cross Modality Image Translation In Medical Imaging Using Generative Frameworks

Magnetic Resonance Imaging (MRI), Computed Tomography (CT), and Positron Emission Tomography (PET) provide complementary information about tissues. Medical image-to-image (I2I) translation enables virtual scanning by synthesizing a target modality from a source one without requiring an additional acquisition. Despite growing interest, many methods operate on 2D slices, are evaluated on isolated tasks under different experimental settings, and lack clinically oriented assessment. This work presents a reproducible benchmark for 3D I2I translation in oncological imaging that compares seven generative models: three Generative Adversarial Networks (Pix2Pix, CycleGAN, and SRGAN) and four latent models (Latent Diffusion Model, Latent Diffusion Model+ControlNet, Brownian Bridge, and Flow Matching). The benchmark comprises 77 experiments across eleven configurations drawn from five datasets, covering three anatomical regions (head/neck, lung, and pelvis) and four translation directions (cone-beam CT to CT, MRI to CT, CT to PET, and T2-weighted MRI to T2-FLAIR). Under the evaluated configurations, SRGAN achieves the highest quantitative image fidelity across all tasks, while latent models perform less well, due to information loss introduced by the variational autoencoder. A tumor-level analysis reveals that all models struggle with small lesions and that, in CT to PET synthesis, models reproduce tumor shape more reliably than tracer uptake values. A Visual Turing test involving 17 physicians, including 15 radiologists, shows near-chance classification accuracy (56.7%), suggesting that experts struggle to distinguish real from synthetic volumes under the viewing conditions of the study. Expert preferences do not follow quantitative rankings, exposing a dissociation between quantitative metrics and clinical preference.
May 13, 2026

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8±21.364.8\pm21.3 HU, PSNR ∼\sim30 dB, MS-SSIM ∼\sim0.936, Dice 0.79, photon γ2%/2mm>98%γ_{2\%/2\text{mm}}>98\%, proton γ≈85%γ\approx85\%. Task 2 improved: MAE 48.3±13.448.3\pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%γ>99\%, proton γ≈89%γ\approx89\%. Strong image--segmentation correlations (ρ=0.78ρ=0.78--0.790.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.
Mar 24, 2026

Mamba-driven MRI-to-CT Synthesis for MRI-only Radiotherapy Planning

Radiotherapy workflows for oncological patients increasingly rely on multi-modal medical imaging, commonly involving both Magnetic Resonance Imaging (MRI) and Computed Tomography (CT). MRI-only treatment planning has emerged as an attractive alternative, as it reduces patient exposure to ionizing radiation and avoids errors introduced by inter-modality registration. While nnU-Net-based frameworks are predominantly used for MRI-to-CT synthesis, we explore Mamba-based architectures for this task to investigate the applicability of state-space modeling for cross-modality medical image translation and assess its performance relative to established convolutional architectures. Specifically, we adapt the SegMamba architecture, originally proposed for segmentation, to perform image-to-image generation. Our 3D Mamba architecture effectively captures complex volumetric features and long-range dependencies, thus allowing accurate CT synthesis while maintaining a relatively low parameter count. Experiments were conducted on a subset of SynthRAD2025 dataset, comprising registered single-channel MRI-CT volume pairs across three anatomical regions. Quantitative evaluation is performed via a combination of image similarity metrics computed in Hounsfield Units (HU) and segmentation-based metrics obtained from TotalSegmentator to ensure geometric consistency is preserved. The findings pave the way for the integration of state-space models into radiotherapy workflows.