cs.CVMar 24, 2026

Mamba-driven MRI-to-CT Synthesis for MRI-only Radiotherapy Planning

Authors: Konstantinos BarmpounakisTheodoros P. VagenasMaria VakalopoulouGeorge K. Matsopoulos

Organizations: School of Electrical and Computer Engineering, National Technical University of Athens · Archimedes, Athena Research Center · CentraleSupélec, University of Paris-Saclay

Abstract

Radiotherapy workflows for oncological patients increasingly rely on multi-modal medical imaging, commonly involving both Magnetic Resonance Imaging (MRI) and Computed Tomography (CT). MRI-only treatment planning has emerged as an attractive alternative, as it reduces patient exposure to ionizing radiation and avoids errors introduced by inter-modality registration. While nnU-Net-based frameworks are predominantly used for MRI-to-CT synthesis, we explore Mamba-based architectures for this task to investigate the applicability of state-space modeling for cross-modality medical image translation and assess its performance relative to established convolutional architectures. Specifically, we adapt the SegMamba architecture, originally proposed for segmentation, to perform image-to-image generation. Our 3D Mamba architecture effectively captures complex volumetric features and long-range dependencies, thus allowing accurate CT synthesis while maintaining a relatively low parameter count. Experiments were conducted on a subset of SynthRAD2025 dataset, comprising registered single-channel MRI-CT volume pairs across three anatomical regions. Quantitative evaluation is performed via a combination of image similarity metrics computed in Hounsfield Units (HU) and segmentation-based metrics obtained from TotalSegmentator to ensure geometric consistency is preserved. The findings pave the way for the integration of state-space models into radiotherapy workflows.

Explore similar work

Jul 7, 2026cs.CV

WING: A Window-Prior-Based Generative Network with Gated Inception for Cross-Modality CT Synthesis

Generating CT volumes from MRI and CBCT can improve treatment planning in adaptive radiotherapy while avoiding additional radiation exposure. However, direct regression of CT intensities is challenged by the inherently high dynamic range and long-tailed distributions, thereby averaging out sparse yet clinically important structures. To alleviate this issue, we reformulate the regression target into multiple windowed representations, leveraging the inductive prior that CT intensities are structure-deterministic and window-separable. These windowed views exhibit smoother distributions and admit structured fusion back to the full-range CT. Building on this reformulation, we introduce WING, a WINdow-prior-based Generative network comprising: 1) a new Gated Inception Generator to produce multi-window predictions, enabling multi-shape kernel interactions to capture cross-modality correspondence; 2) a Fuse-and-Refine Transformer to aggregate the windowed outputs and learn residuals for detail refinement; and 3) a joint adversarial training objective to enhance window-conditioned realism. Extensive experiments demonstrate that our compact WING achieves state-of-the-art performance on the MRI-to-CT and CBCT-to-CT benchmarks, while supporting multi-anatomy synthesis with a single model.
Siyuan Mei, Yan Xia, Yipeng Sun +7
May 13, 2026physics.med-ph

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8±21.364.8\pm21.3 HU, PSNR \sim30 dB, MS-SSIM \sim0.936, Dice 0.79, photon γ2%/2mm>98%γ_{2\%/2\text{mm}}>98\%, proton γ85%γ\approx85\%. Task 2 improved: MAE 48.3±13.448.3\pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%γ>99\%, proton γ89%γ\approx89\%. Strong image--segmentation correlations (ρ=0.78ρ=0.78--0.790.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.
Viktor Rogowski, Maarten L. Terpstra, Niklas Wahl +30
Apr 30, 2026eess.IV

A Proof-of-Concept Study of Multitask Learning for Cranial Synthetic CT Generation Across Heterogeneous MRI Field Strengths

Accurate synthesis of computed tomography (CT) images from magnetic resonance imaging (MRI) is clinically valuable for cranial applications such as attenuation correction, radiotherapy planning, and image-guided interventions. However, heterogeneity across MRI field strengths and acquisition protocols limits the generalizability of existing methods. In this study, we formulate cranial CT synthesis as a modular, structurally coupled problem and propose a deep learning framework to improve robustness across heterogeneous MRI conditions. The model is designed to adapt to variations in field strength and imaging protocols while preserving anatomical consistency. Experiments on multi-site datasets demonstrate improved performance and generalization compared with conventional approaches. The proposed method enables reliable CT synthesis across heterogeneous MRI settings, supporting broader clinical translation.
Zhuoyao Xin, Yiren Zhang, Christopher Wu +6