cs.LGMar 15, 2026

Artificial intelligence-enabled single-lead ECG for non-invasive hyperkalemia detection: development, multicenter validation, and proof-of-concept deployment

Authors: Gongzheng Tang, Qinghao Zhao, Guangkun Nie, Yujie Xiao, Shijia Geng, Donglin Xie, Shun Huang, Deyun Zhang, 

Organizations: Institute of Medical Technology, Peking University Health Science Center, Beijing, China · National Institute of Health Data Science, Peking University, Beijing, China · Department of Cardiology, Peking University People’s Hospital, Beijing, China · School of Intelligence Science and Technology, Peking University, Beijing, China · 

Abstract

Hyperkalemia is a life-threatening electrolyte disorder that is common in patients with chronic kidney disease and heart failure, yet frequent monitoring remains difficult outside hospital settings. We developed and validated Pocket-K, a single-lead AI-ECG system initialized from the ECGFounder foundation model for non-invasive hyperkalemia screening and handheld deployment. In this multicentre observational study using routinely collected clinical ECG and laboratory data, 34,439 patients contributed 62,290 ECG--potassium pairs. Lead I data were used to fine-tune the model. Data from Peking University People's Hospital were divided into development and temporal validation sets, and data from The Second Hospital of Tianjin Medical University served as an independent external validation set. Hyperkalemia was defined as venous serum potassium > 5.5 mmol/L. Pocket-K achieved AUROCs of 0.936 in internal testing, 0.858 in temporal validation, and 0.808 in external validation. For KDIGO-defined moderate-to-severe hyperkalemia (serum potassium >= 6.0 mmol/L), AUROCs increased to 0.940 and 0.861 in the temporal and external sets, respectively. External negative predictive value exceeded 99.3%. Model-predicted high risk below the hyperkalemia threshold was more common in patients with chronic kidney disease and heart failure. A handheld prototype enabled near-real-time inference, supporting future prospective evaluation in native handheld and wearable settings.

Figures & tables

Explore similar work

Apr 10, 2026

Biomarker-Based Pretraining for Chagas Disease Screening in Electrocardiograms

Chagas disease screening via ECGs is limited by scarce and noisy labels in existing datasets. We propose a biomarker-based pretraining approach, where an ECG feature extractor is first trained to predict percentile-binned blood biomarkers from the MIMIC-IV-ECG dataset. The pretrained model is then fine-tuned on Brazilian datasets for Chagas detection. Our 5-model ensemble, developed by the Ahus AIM team, achieved a challenge score of 0.269 on the hidden test set, ranking 5th in Detection of Chagas Disease from the ECG: The George B. Moody PhysioNet Challenge 2025. Source code and the model are shared on GitHub: github.com/Ahus-AIM/physionet-challenge-2025
Feb 28, 2026

A Novel end-to-end Digital Health System Using Deep Learning-based ECG Analysis

This study presents AI-HEART, a cloud-based information system for managing and analysing long-duration ambulatory electrocardiogram (ECG) recordings and supporting clinician decision-making. The platform operationalises an end-to-end pipeline that ingests multi-day three-lead ECGs, normalises inputs, performs signal preprocessing, and applies dedicated deep neural networks for wave delineation, noise/quality detection, and beat- and rhythm-level multi-class arrhythmia classification. To address class imbalance and real-world signal variability, model development combines large clinically annotated datasets with expert-in-the-loop curation and generative augmentation for under-represented rhythms. Empirical evaluation on three-lead ambulatory ECG data shows that delineation accuracy is sufficient for automated interval measurement, noise detection reliably flags poor-quality segments, and arrhythmia classification achieves high specificity with clinically useful macro-averaged performance across common and rarer rhythms. Beyond predictive accuracy, AI-HEART provides a scalable deployment approach for integrating AI into routine ECG services, enabling traceable outputs, audit-friendly storage of recordings and derived annotations, and clinician review/editing that captures feedback for controlled model improvement. The findings demonstrate the technical feasibility and operational value of a noise-aware AI-ECG platform as a digital health information system.
Oct 20, 2026

ECG for laboratory values:A comprehensive physiological and technical analysis

Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG recordings may contain information beyond cardiac rhythm and provide information related to laboratory values. This thesis investigates NT-proBNP prediction from ECG recordings and patient metadata using a multimodal deep learning framework, while considering the physiological plausibility of ECG-based prediction. It also compares a 1-lead configuration using lead II with the corresponding 12-lead configuration. Additional experiments on glucose, hemoglobin, and potassium are presented in the appendix. Regression, binary classification, and three-class classification experiments were conducted using MIMIC-IV, with the three-class task based on clinically established thresholds. The 12-lead configuration consistently achieved better performance. Regression reached a mean absolute error of 534.98 pg/mL for 1-lead and 514.27 pg/mL for 12-lead. Binary classification achieved AUROCs of 0.849 and 0.876, respectively, while three-class classification achieved macro-averaged AUROCs of 0.738 and 0.752. The results indicate that precise NT-proBNP regression remains challenging, whereas broader concentration ranges can be classified more effectively. The findings are consistent with the physiological hypothesis that ECG characteristics and NT-proBNP concentrations reflect shared cardiovascular processes. ECG-based NT-proBNP prediction may therefore provide complementary information, particularly for classifying broader concentration ranges. However, laboratory measurements remain necessary, and validation on independent datasets is required.