LUMINA: A Multi-Vendor Mammography Benchmark with Energy Harmonization Protocol
Authors: Hongyi Pan, Gorkem Durak, Halil Ertugrul Aktas, Andrea M. Bejar, Baver Tutun, Emre Uysal, Ezgi Bulbul, Mehmet Fatih Dogan, +4 more
Organizations: Department of Radiology, Northwestern University, Chicago, IL, USA · Department of Radiation Oncology, University of Health Sciences Prof. Dr. Cemil Tascioglu City Hospital, Istanbul, Turkey · Department of Radiology, Istanbul University, Istanbul, Turkey
Publicly available full-field digital mammography (FFDM) datasets remain limited in size, clinical annotations, and vendor diversity, hindering the development of robust models. We introduce LUMINA, a curated, multi-vendor FFDM dataset that explicitly encodes acquisition energy and vendor metadata to capture clinically relevant appearance variations often overlooked in existing benchmarks. This dataset contains 1824 images from 468 patients (960 benign, 864 malignant), with pathology-confirmed labels, BI-RADS assessments, and breast-density annotations. LUMINA spans six acquisition systems and includes both high- and low-energy imaging styles, enabling systematic analysis of vendor- and energy-induced domain shifts. To address these variations, we propose a foreground-only pixel-space alignment method (''energy harmonization'') that maps images to a low-energy reference while preserving lesion morphology. We benchmark CNN and transformer models on three clinically relevant tasks: diagnosis (benign vs. malignant), BI-RADS classification, and density estimation. Two-view models consistently outperform single-view models. EfficientNet-B0 achieves an AUC of 93.54% for diagnosis, while Swin-T achieves the best macro-AUC of 89.43% for density prediction. Harmonization improves performance across architectures and produces more localized Grad-CAM responses. Overall, LUMINA provides (1) a vendor-diverse benchmark and (2) a model-agnostic harmonization framework for reliable and deployable mammography AI.
Figures & tables
Figure 1: Representative benign and malignant mammograms.
Pathology
BI-RADS
Breast
Acquisition
Dataset
Origin
Patients
Images
Labels
Assessment
Density
Technique
MIAS [ 30 ]
UK
161
322
Yes
No
No
SFM
DDSM [ 4 ]
USA
2,620
10,480
Yes
Yes
Yes
SFM
CBIS-DDSM [ 14 ]
USA
2,620
10,239
Yes
Yes
Yes
SFM
INbreast [ 19 ]
Portugal
115
410
No
Yes
Yes
FFDM
VinDR-Mammo [ 22 ]
Vietnam
5,000
20,000
No
Yes
Yes
FFDM
Table 1: Comparison of publicly available mammography datasets.
Figure 2: Age, BI-RADS, and breast distribution.
Vendor
# Patients
# Images
Energy
IMS
341
1326
High
Metaltronica
91
354
Low
FUJIFILM Corporation
29
116
Low
SIEMENS
4
16
Low
Carestream Health
1
4
Low
GE MEDICAL SYSTEMS
2
8
High
Table 2: Vendor distribution.
Figure 3: LUMINA pipeline. The EfficientNet-B0 backbone can be replaced by other backbones (ResNet-50, DenseNet-121, and Swin-T). Two‑view shared‑backbone reached accuracy comparable to independent‑backbone with 48% less parameters (Table 7 ) and outperformed four‑view variants (Table 4 ).
View
Benign
Malignant
Total
Single
592 (592)
344 (344)
936 (936)
Two
296 (592)
172 (344)
468 (936)
Table 3: Breast cancer diagnosis task data distribution. Numbers outside and inside brackets are cases and images, respectively.
Figure 4: Background influence. Standard histogram matching is degraded by large black background regions, whereas foreground-only histogram matching remains unaffected.
View
Model
Input
Params
Flops
ACC(%)
AUC(%)
Precision(%)
Recall(%)
F1(%)
Specificity(%)
Single
ResNet-50
2242
23.51M
4.13G
79.49 ± 5.99
87.42 ± 4.21
81.29 ± 10.90
61.97 ± 18.17
67.52 ± 13.09
89.68 ± 9.63
DenseNet-121
2242
6.95M
2.90G
79.49 ± 3.37
87.14 ± 3.08
80.45 ± 9.45
62.55 ± 17.56
67.79 ± 9.57
89.38 ± 7.52
EfficientNet-B0
2242
4.01M
0.41G
83.12 ± 4.13
90.66 ± 4.21
79.78 ± 6.31
73.89 ± 15.77
75.50 ± 7.95
88.51 ± 5.00
Swin-T
2242
27.52M
3.13G
81.84 ± 5.92
88.62 ± 5.18
78.27 ± 8.63
71.83 ± 12.10
74.16 ± 8.36
87.66 ± 7.45
ResNet-50
5122
23.51M
21.58G
77.68 ± 7.18
86.69 ± 4.37
82.79 ± 14.09
59.36 ± 28.73
61.41 ± 22.78
88.38 ± 12.29
DenseNet-121
5122
6.95M
15.14G
79.38 ± 5.55
90.52 ± 3.61
81.32 ± 16.39
68.09 ± 21.96
69.22 ± 11.98
85.99 ± 14.42
Table 4: Mammogram cancer diagnosis benchmark. The best and second-best results are highlighted in green and yellow, respectively.
Two-Class (BI-RADS 1/2/3 VS 4/5/6)
Three-Class (BI-RADS 1/2 VS 3/4 VS 5/6)
Model
Input
ACC(%)
AUC(%)
F1(%)
ACC(%)
AUC(%)
F1(%)
ResNet-50
2242
71.98 ± 12.34
88.23 ± 3.52
62.45 ± 10.33
69.02 ± 5.14
79.58 ± 3.00
55.36 ± 1.97
DenseNet-121
2242
77.55 ± 3.67
87.89 ± 3.52
58.98 ± 14.70
68.15 ± 3.12
80.90 ± 3.74
48.63 ± 3.49
EfficientNet-B0
2242
83.56 ± 4.76
92.80 ± 4.13
74.18 ± 9.32
71.78 ± 5.03
83.27 ± 4.91
55.15 ± 4.65
Swin-T
2242
79.29 ± 9.01
90.80 ± 4.61
60.82 ± 31.02
70.51 ± 4.45
81.69 ± 5.55
49.55 ± 6.85
ResNet-50
5122
75.22 ± 4.46
89.08 ± 5.42
64.78 ± 9.96
66.66 ± 3.10
78.92 ± 4.91
50.71 ± 3.73
Table 5: BI-RADS classification benchmark.
Model
Input
ACC(%)
AUC(%)
F1(%)
ResNet-50
2242
64.74 ± 3.33
85.66 ± 1.62
56.94 ± 6.43
DenseNet-121
2242
66.29 ± 4.20
86.39 ± 2.92
56.70 ± 2.97
EfficientNet-B0
2242
59.43 ± 5.23
84.72 ± 3.54
48.25 ± 5.68
Swin-T
2242
70.35 ± 4.60
89.43 ± 2.22
65.28 ± 6.48
ResNet-50
5122
65.37 ± 4.07
87.06 ± 2.10
58.29 ± 7.57
DenseNet-121
5122
66.31 ± 5.31
86.60 ± 3.76
61.42 ± 7.62
Table 6: Density classification benchmark.
Figure 5: t-SNE visualization for diagnosis task. Higher resolution increases benign/malignant separation in the latent space.
Backbone
Input
Params
ACC(%)
AUC(%)
F1(%)
Indepen-
2242
8.34M
84.82 ± 3.00
93.54 ± 2.38
77.41 ± 6.13
dent
5122
8.34M
88.46 ± 4.91
92.71 ± 4.63
82.19 ± 8.61
Shared
2242
4.34M
86.11 ± 2.47
92.99 ± 3.04
79.39 ± 4.18
5122
4.34M
85.04 ± 5.92
93.54 ± 3.88
75.75 ± 12.85
Table 7: Shared vs. independent two-view EfficientNet-B0 backbones. Flops are 0.82G for 2242 and 4.27G under 5122 .
Figure 6: Harmonization improves ACC, AUC, and F1-Score across tasks. Bars show mean ± std over 5 folds, and curves show the mean ROC. How to read: In (a) and (b), darker bars (harmonized) consistently exceed lighter bars (raw). In (c) and (d), areas under the blue and orange (harmonized) curves are respectively larger than areas under the green and red (raw) curves. Takeaway: Pixel-space CDF alignment helps regardless of backbone or input size, supporting its use as a robust pre-processing step.
Figure 7: Attention becomes more focal after harmonization. Shown are raw (left two columns) vs. harmonized (right two columns) inputs with Grad-CAM overlays for two malignant cases. Observation: Harmonization reduces diffuse activations and concentrates attention on lesion-bearing regions. Implication: Harmonization not only improves metrics (Fig. 6 ) but may also enhance clinical interpretability by focusing on suspicious tissue.
Vendor/energy diversity; three tasks; consistent harmonization gains; improved attention focus.
Table 8: Positioning. LUMINA provides pathology, BI-RADS, and density on multi-vendor FFDM, plus a simple, effective pixel‑space harmonization baseline.
Backbone
Pre-trained
Learning Rate
Weight Decay
Epochs
Learning Rate scheduler
Batch
Augmentation
ResNet-50
ImageNet-1K
1×10−3
1×10−5
100
×0.1 every 30
32
flip, resize
DenseNet-121
ImageNet-1K
1×10−3
1×10−5
100
×0.1 every 30
32
flip, resize
EfficientNet-B0
ImageNet-1K
1×10−3
1×10−5
100
×0.1 every 30
32
flip, resize
Swin-T
ImageNet-1K
1×10−5
1×10−5
100
×0.1 every 30
32
flip, resize
Table 9: Hyperparameter parity across backbones. Shared schedule and augmentations ensure a fair comparison (see Sec. 6.1 ).
Stage
Operation (applied to all models equally)
DICOM handling
Convert MONOCHROME1 to MONOCHROME2; remove text burn-ins.
Foreground mask
Define M={(x,y)∣I(x,y)>0} ; exclude background from histograms.
Harmonization
Foreground CDF matching to low-energy reference (Eqs. 1–8); training-free, model-agnostic.
Resize/replicate
Resize to 2242 or 5122 ; replicate grayscale to 3 channels for ImageNet backbones (Sec. 6.1 ).
Augment
Random horizontal flip (all backbones, all tasks).
Normalization
As in backbone defaults; no per-model special tuning beyond LR noted in Sec. 6.1 .
Table 10: Shared pre-processing. Ensures identical inputs across backbones; isolates model differences.
College of Engineering and Computer Science, VinUniversity, Hanoi, Vietnam · Imperial College London, London, UK · Radiology Department, Vietnam National Cancer Hospital, Hanoi, Vietnam +2
Sep 13, 2026·Ali Abbasian Ardakani, Afshin Mohammadi, Taha Yusuf Kuzan +11Medical VLMsMammography
Department of Medicine, Faculty of Medicine and Dentistry, Danube Private University, Krems an der Donau, Austria · Department of Radiology, Faculty of Medicine, Urmia University of Medical Science, Urmia, Iran · Department of Radiology, Yeditepe University, Istanbul, Türkiye +10