cs.CVMar 23, 2026

Sketch2CT: Multimodal Diffusion for Structure-Aware 3D Medical Volume Generation

Authors: Delin An, Chaoli Wang

Organizations: University of Notre Dame

Abstract

Diffusion probabilistic models have demonstrated significant potential in generating high-quality, realistic medical images, providing a promising solution to the persistent challenge of data scarcity in the medical field. Nevertheless, producing 3D medical volumes with anatomically consistent structures under multimodal conditions remains a complex and unresolved problem. We introduce Sketch2CT, a multimodal diffusion framework for structure-aware 3D medical volume generation, jointly guided by a user-provided 2D sketch and a textual description that captures 3D geometric semantics. The framework initially generates 3D segmentation masks of the target organ from random noise, conditioned on both modalities. To effectively align and fuse these inputs, we propose two key modules that refine sketch features with localized textual cues and integrate global sketch-text representations. Built upon a capsule-attention backbone, these modules leverage the complementary strengths of sketches and text to produce anatomically accurate organ shapes. The synthesized segmentation masks subsequently guide a latent diffusion model for 3D CT volume synthesis, enabling realistic reconstruction of organ appearances that are consistent with user-defined sketches and descriptions. Extensive experiments on public CT datasets demonstrate that Sketch2CT achieves superior performance in generating multimodal medical volumes. Its controllable, low-cost generation pipeline enables principled, efficient augmentation of medical datasets. Code is available at https://github.com/adlsn/Sketch2CT.

Figures & tables

Appendix figures & tables5 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 31, 2026

MedSyn2: Flexible Control of 3D CT Generation via Text and Semantically-Defined Segmentation Prompts

Generative models for volumetric medical images have found many applications in medical imaging, ranging from data augmentation to serving as priors for inverse problems. For these applications, generating high-resolution 3D images with strong controllability is essential but remains highly challenging. Existing approaches typically control generation either through radiology reports used as text prompts or through full image segmentation. While text-based prompting is flexible, it provides limited spatial control over the location, shape, and boundary of abnormalities. In contrast, segmentation-based methods receive precise spatial guidance but are restrictive in requiring full-organ annotations. In this work, we propose a flexible multimodal framework for controllable volumetric image generation that supports input from radiology reports and segmentation prompts (both optional). Our approach allows users to provide segmentation of a specific anatomy or abnormality without requiring full-organ annotations. The semantic meaning of the segmentation mask is specified through an accompanying text description, resulting in a highly flexible and scalable conditioning mechanism. We develop a memory-efficient architecture based on a modified diffusion transformer that jointly processes image and segmentation tokens. The model further incorporates gated attention to effectively attend to long radiology reports. Experiments demonstrate that our method achieves state-of-the-art perceptual and semantic scores (e.g., 24% relative improvement in mean FID), generates high-resolution anatomically consistent CT volumes, and improves data efficiency when used for data augmentation. Radiologists' evaluation further confirms strong alignment between generated and real medical images.
Jun 18, 2026

Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume Generation

Generating high-resolution 3D CT volumes with fine details remains challenging due to substantial computational demands and optimization difficulties inherent to existing generative models. In this paper, we propose the Pixel-Level Residual Diffusion Transformer (PRDiT), a scalable generative framework that synthesizes high-quality 3D medical volumes directly at voxel-level. PRDiT introduces a two-stage training architecture comprising 1) a local denoiser in the form of an MLP-based blind estimator operating on overlapping 3D patches to separate low-frequency structures efficiently, and 2) a global residual diffusion transformer employing memory-efficient attention to model and refine high-frequency residuals across entire volumes. This coarse-to-fine modeling strategy simplifies optimization, enhances training stability, and effectively preserves subtle structures without the limitations of an autoencoder bottleneck. Extensive experiments conducted on the LIDC-IDRI and RAD-ChestCT datasets demonstrate that PRDiT consistently outperforms state-of-the-art models, such as HA-GAN, 3D LDM and WDM-3D, achieving significantly lower 3D FID, MMD and Wasserstein distance scores.
Mar 9, 2026

Retrieval-Augmented Anatomical Guidance for Text-to-CT Generation

Text-conditioned generative models for volumetric medical imaging provide semantic control but lack explicit anatomical guidance, often resulting in outputs that are spatially ambiguous or anatomically inconsistent. In contrast, structure-driven methods ensure strong anatomical consistency but typically assume access to ground-truth annotations, which are unavailable when the target image is to be synthesized. We propose a retrieval-augmented approach for Text-to-CT generation that integrates semantic and anatomical information under a realistic inference setting. Given a radiology report, our method retrieves a semantically related clinical case using a 3D vision-language encoder and leverages its associated anatomical annotation as a structural proxy. This proxy is injected into a text-conditioned latent diffusion model via a ControlNet branch, providing coarse anatomical guidance while maintaining semantic flexibility. Experiments on the CT-RATE dataset show that retrieval-augmented generation improves image fidelity and clinical consistency compared to text-only baselines, while additionally enabling explicit spatial controllability, a capability inherently absent in such approaches. Further analysis highlights the importance of retrieval quality, with semantically aligned proxies yielding consistent gains across all evaluation axes. This work introduces a principled and scalable mechanism to bridge semantic conditioning and anatomical plausibility in volumetric medical image synthesis. Code is available at https://github.com/arco-group/RAGText2CT.