cs.CVMar 27, 2026

OSA: Echocardiography Video Segmentation via Orthogonalized State Update and Anatomical Prior-aware Feature Enhancement

Authors: Rui Wang, Huisi Wu, Jing Qin

Organizations: College of Computer Science and Software Engineering, Shenzhen University · Centre for Smart Health, School of Nursing, The Hong Kong Polytechnic University

Abstract

Accurate and temporally consistent segmentation of the left ventricle from echocardiography videos is essential for estimating the ejection fraction and assessing cardiac function. However, modeling spatiotemporal dynamics remains difficult due to severe speckle noise and rapid non-rigid deformations. Existing linear recurrent models offer efficient in-context associative recall for temporal tracking, but rely on unconstrained state updates, which cause progressive singular value decay in the state matrix, a phenomenon known as rank collapse, resulting in anatomical details being overwhelmed by noise. To address this, we propose OSA, a framework that constrains the state evolution on the Stiefel manifold. We introduce the Orthogonalized State Update (OSU) mechanism, which formulates the memory evolution as Euclidean projected gradient descent on the Stiefel manifold to prevent rank collapse and maintain stable temporal transitions. Furthermore, an Anatomical Prior-aware Feature Enhancement module explicitly separates anatomical structures from speckle noise through a physics-driven process, providing the temporal tracker with noise-resilient structural cues. Comprehensive experiments on the CAMUS and EchoNet-Dynamic datasets show that OSA achieves state-of-the-art segmentation accuracy and temporal stability, while maintaining real-time inference efficiency for clinical deployment. Codes are available at https://github.com/wangrui2025/OSA.

Figures & tables

Appendix figures & tables2 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 8, 2026

Automatic Echocardiography Segmentation via Transition Probability Correlation for Stable Semantic Extraction

While echocardiography is essential for cardiovascular diagnosis, inherent speckle noise and low signal-to-noise ratio often lead to ambiguous semantic features and fragmented boundaries. These limitations significantly hinder the segmentation accuracy of deep learning models in complex clinical cases. Moreover, temporal motion of the heart plays a critical role in recognizing anatomical structures. To address these challenges, we designed a STLSF module which comprises a window-matching-based semantic correction component and a semantics-guided texture enhancement component. By leveraging local transition probability correlations to correct semantics and employing semantics-guided texture enhancement, the STLSF module effectively mitigates texture instability and ambiguous semantic interpretations caused by disadvantaged echocardiography quality. Additionally, to facilitate the encoder's adaptation to the intrinsic priors of ultrasound-specific imaging patterns, we propose a frequency-aware denoising pre-training method. The entire work builds a convolution-based network with locality inductive bias and long-range dependencies. Extensive experiments confirm our SOTA performance, achieving 93.87% Dice on CAMUS and 92.62% on EchoNet-Dynamic, with respective HD95 values of 3.29mm and 2.73mm.
Jun 16, 2026

Spatio-Temporal Fusion Model for Standard View Classification of Echocardiographic Videos

Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges. First, publicly available datasets are scarce and limited in scale and view coverage. Second, the performance of some modern video-level architectures for echocardiographic view classification remains underexplored. Third, some view categories exhibit highly similar spatial appearances, making single-frame features insufficient for discrimination, while heterogeneous frame quality complicates robust temporal information fusion. To address these challenges, we release the Echocardiographic Videos of Nine Views (EV9V) dataset, comprising 5,138 videos, 910,579 frames, and 9 standard views, which is, to the best of our knowledge, the largest publicly available echocardiography video dataset. Using EV9V, we systematically benchmark representative video classification architectures, including Convolutional Neural Networks (CNNs), Recurrent Neural Networks (RNNs), and Transformers. Furthermore, we propose a Spatio-Temporal Fusion Model (STFM), an efficient dual-stream CNN-LSTM (Long Short-Term Memory) framework that jointly captures spatial anatomical structures and temporal cardiac dynamics. The proposed framework leverages uncertainty-aware learning to preferentially sample representative video segments during training and evidence-based fusion during inference, improving robustness to variations in frame quality across echocardiographic videos. Extensive experiments demonstrate that our method achieves competitive performance across diverse video classification models, validating the effectiveness of uncertainty-aware spatio-temporal learning for echocardiographic view classification. The code is available at https://github.com/bgx666/stfm.
Sep 17, 2026

The segmentation ceiling: why explicit left-ventricular masks do not improve learned ejection-fraction regression

Accurate estimation of left ventricular ejection fraction (EF) from echocardiography is central to cardiovascular care, and deep learning enables automated EF prediction from echocardiographic video. Because EF is clinically derived from left-ventricular (LV) volumes, a widely held intuition is that explicit LV segmentation should improve prediction. We introduce a quantitative criterion, the segmentation ceiling, that makes this testable: from EF as a normalized difference of end-diastolic and end-systolic volumes, we derive in closed form how per-frame segmentation area error propagates into EF error, and thus the accuracy a mask must reach before it can improve on direct regression. Using EchoNet-Dynamic, a UniFormer-S backbone, and the empirically measured within-patient error correlation, the criterion places the break-even near 10% per-frame area error, whereas a representative segmenter operates at roughly 14%, above the ceiling. Consistent with this, four strategies for injecting segmentation or area information (a predicted-mask channel, end-diastolic/end-systolic clip sampling, and per-bin and amplitude area-consistency objectives) fail to beat a raw-video baseline; ground-truth masks help only through label leakage. Input representation thus not being the limit, we identify generalization as the practical lever: weight averaging with strong augmentation attains a test R^2 of 0.806 (MAE 4.08) under a matched dense-clip protocol, comparable to an R(2+1)D baseline (0.811) while tightening the validation-to-test gap. Finally, a heteroscedastic beta-NLL formulation yields informative, well-calibrated per-prediction uncertainty, larger for clinically harder low-EF cases, where Monte-Carlo dropout does not. The segmentation ceiling gives a concrete design criterion for when mask-guided EF estimation is worthwhile, plus a simple, uncertainty-aware recipe for EF regression.