EMPD: An Event-based Multimodal Physiological Dataset for Remote Pulse Wave Detection
Organizations: College of Computer Science and Technology, Taiyuan University of Technology
Abstract
Remote photoplethysmography (rPPG) based on traditional frame-based cameras often struggles with motion artifacts and limited temporal resolution. To address these limitations, we introduce EMPD (Event-based Multimodal Physiological Dataset), the first benchmark dataset specifically designed for non-contact physiological sensing via event cameras. The dataset leverages a laser-assisted acquisition system where a high-coherence laser modulates subtle skin vibrations from the radial artery into significant signals detectable by a neuromorphic sensor. The hardware platform integrates a high-resolution event camera to capture micro-motions and intensity transients, an industrial RGB camera to provide traditional rPPG benchmarks, and a clinical-grade pulse oximeter to record ground truth PPG waveforms. EMPD contains 193 valid records collected from 83 subjects, covering a wide heart rate range (40-110 BPM) under both resting and post-exercise conditions. By providing precisely synchronized multimodal data with microsecond-level temporal precision, EMPD serves as a crucial resource for developing robust algorithms in the field of neuromorphic physiological monitoring. The dataset is publicly available at: https://doi.org/10.5281/zenodo.18765701
Figures & tables
| Datasets | Year | Subjects | Sensor modality | Total duration | Scene diversity |
| PURE Stricker et al. [2014] | 2014 | 10 | RGB Camera, Pulse Oximeter | 60min | Head motions, Talk, Lighting |
| UBFC-RPPG Bobbia et al. [2019] | 2019 | 42 | RGB Webcam, Pulse Oximeter | 70min | Math game, Stress induction |
| OBF Li et al. [2018] | 2018 | 106 | RGB & NIR Camera, ECG | 1000min | Atrial fibrillation, Exercise |
| MMPD Tang et al. [2023] | 2023 | 33 | Mobile Camera, Pulse Oximeter | 660min | Mobile, Multi-lighting, Exercise |
| MSPM Speth et al. [2024] | 2024 | 103 | RGB, NIR, Thermal, Contact PPG | 1480min | Multi-site, BP, Breath hold |
| EMPD (Ours) | 2025 | 83 | Event & RGB Camera, Pulse Oximeter | 219min | Rest, Exercise |
| Category | Method | MAE (bpm) | RMSE (bpm) | MAPE (%) | PCC | SNR |
| Supervised | POS Wang et al. [2016] | 4.23 | 6.99 | 5.80 | 0.81 | -0.16 |
| ICA Poh et al. [2010] | 5.79 | 10.73 | 7.61 | 0.61 | -0.01 | |
| GREEN Verkruysse et al. [2008] | 7.29 | 13.04 | 9.30 | 0.57 | -1.44 | |
| CHROM De Haan and Jeanne [2013] | 3.57 | 5.69 | 4.88 | 0.89 | 0.44 | |
| LGI Pilz et al. [2018] | 5.87 | 10.22 | 7.61 | 0.70 | -1.93 | |
| PBV De Haan and Van Leest [2014] | 7.36 | 12.26 | 9.91 | 0.58 | -2.78 |
Remote Photoplethysmography
Remote photoplethysmography (rPPG) estimates pulse and other physiological signals from video without contact sensors.
See all 46 papers