cs.CVApr 3, 2026

Effect of Input Resolution on Retinal Vessel Segmentation Performance: An Empirical Study Across Five Datasets

Authors: Amarnath R

Organizations: United Institute of Technology, Coimbatore, India

Abstract

Most deep learning pipelines for retinal vessel segmentation resize fundus images to satisfy GPU memory constraints and enable uniform batch processing. However, the impact of this resizing on thin vessel detection remains underexplored. When high resolution images are downsampled, thin vessels are reduced to subpixel structures, causing irreversible information loss even before the data enters the network. Standard volumetric metrics such as the Dice score do not capture this loss because thick vessel pixels dominate the evaluation. We investigated this effect by training a baseline UNet at multiple downsampling ratios across five fundus datasets (DRIVE, STARE, CHASE_DB1, HRF, and FIVES) with native widths ranging from 565 to 3504 pixels, keeping all other settings fixed. We introduce a width-stratified sensitivity metric that evaluates thin (half-width <3 pixels), medium (3 to 7 pixels), and thick (>7 pixels) vessel detection separately, using native resolution width estimates derived from a Euclidean distance transform. Results show that for high-resolution datasets (HRF, FIVES), thin vessel sensitivity improves monotonically as images are downsampled toward the encoder's effective operating range, peaking at processed widths between 256 and 876 pixels. For low-to-mid resolution datasets (DRIVE, STARE, CHASE_DB1), thin vessel sensitivity is highest at or near native resolution and degrades with any downsampling. Across all five datasets, aggressive downsampling reduced thin vessel sensitivity by up to 15.8 percentage points (DRIVE) while Dice remained relatively stable, confirming that Dice alone is insufficient for evaluating microvascular segmentation.

Explore similar work

Mar 23, 2026

HMS-VesselNet: Hierarchical Multi-Scale Attention Network with Topology-Preserving Loss for Retinal Vessel Segmentation

Retinal vessel segmentation methods based on standard overlap losses tend to miss thin peripheral vessels because these structures occupy very few pixels and have low contrast against the background. We propose HMS-VesselNet, a hierarchical multi-scale network that processes fundus images across four parallel branches at different resolutions and combines their outputs using learned fusion weights. The training loss combines Dice, binary cross-entropy, and centerline Dice to jointly optimize area overlap and vessel continuity. Hard example mining is applied from epoch 20 onward to concentrate gradient updates on the most difficult training images. Tested on 68 images from DRIVE, STARE, and CHASE_DB1 using 5-fold cross-validation, the model achieves a mean Dice of 88.72 +/- 0.67%, Sensitivity of 90.78 +/- 1.42%, and AUC of 98.25 +/- 0.21%. In leave-one-dataset-out experiments, AUC remains above 95% on each unseen dataset. The largest improvement is in the recall of thin peripheral vessels, which are the structures most frequently missed by standard methods and most critical for early detection of diabetic retinopathy.
Jun 3, 2026

LightVesselNet: An Ultra-Lightweight Sub-100K Parameter Network for Retinal Blood Vessel Segmentation

Retinal blood vessel segmentation plays a vital role in the early detection of diabetic retinopathy and glaucoma. While recent deep learning models have achieved great segmentation accuracy, they typically require heavy computational resources, making real-world deployment on edge devices difficult. In this paper, we propose LightVesselNet, an efficient neural network designed for retinal vessel segmentation in a resource-constrained environment. Despite containing only 75K parameters, LightVesselNet performs competitively with much larger models. The network employs a compact encoder decoder architecture enhanced with channel and spatial attention mechanisms, a multi-scale feature aggregation module at the bottleneck, and a subpixel upsampling strategy in the decoder. A dedicated edge residual connection preserves fine vessel detail throughout decoding. Extensive experiments on five publicly available datasets: DRIVE, STARE, CHASEDB1, FIVES, and HRF, yield sensitivity scores of 0.8189, 0.8499, 0.8640, 0.8634, 0.8096, and Dice coefficients of 0.8070, 0.8072, 0.8181, 0.8649, and 0.7686, respectively. LightVesselNet shows improved efficiency (Performance vs Parameter or GFlops) compared to State-of-the-Art models. Cross-dataset evaluation confirms the model's generalisation capability. Overall, LightVesselNet is a strong candidate for deployment in low-resource clinical settings and mobile screening tools.
Sep 21, 2026

U-PEN Mamba: Progressive Expansion with Selective State-Space Modeling for Efficient Retinal Vessel Segmentation

Accurate retinal vessel segmentation is important for computer-aided ophthalmic analysis, yet thin vessels, low contrast, and severe foreground-background imbalance remain challenging for encoder-decoder networks. This paper presents U-PEN Mamba, a U-shaped retinal vessel segmentation architecture that couples progressive nonlinear feature expansion with selective state-space modeling. The proposed network enriches local vessel responses with progressive expansion, models long-range spatial dependencies through a Mamba Global Context (MGC) block with linear sequence complexity, and uses attention-based decoder fusion to recover fine vascular boundaries. We evaluate U-PEN Mamba on CHASE DB1 and DRIVE using a consistent patch-based preprocessing pipeline and compare it with convolutional, attention-based, transformer-based, and Mamba-based segmentation baselines. U-PEN Mamba obtains the best mean intersection over union among the compared methods, achieving 0.8394 on CHASE DB1 and 0.8221 on DRIVE, with Dice scores of 0.8187 and 0.8078, respectively, using 21.6M trainable parameters. Ablation studies show that the MGC block contributes the largest gain over the U-Net baseline, while projection dimension and state size provide practical accuracy-efficiency control. These results indicate that selective state-space modeling is a promising global-context mechanism for parameter-efficient retinal vessel segmentation. Code is available at: https://github.com/areyesan/UPEN_Mamba.