cs.CVApr 10, 2026

Robust by Design: A Continuous Monitoring and Data Integration Framework for Medical AI

Authors: Mohammad Daouk, Jan Ulrich Becker, Neeraja Kambham, Anthony Chang, Chandra Mohan, Hien Van Nguyen

Organizations: University of Houston, Houston, TX, USA · University Hospital Cologne, Cologne, Germany · Stanford University, Stanford, CA, USA · The University of Chicago, Chicago, IL, USA

Abstract

Adaptive medical AI models often face performance drops in dynamic clinical environments due to data drift. We propose an autonomous continuous monitoring and data integration framework that maintains robust performance over time. Focusing on glomerular pathology image classification (proliferative vs. non-proliferative lupus nephritis), our three-stage method uses multi-metric feature analysis and Monte Carlo dropout-based uncertainty gating to decide when to retrain on new data. Only images statistically similar to the training distribution (via Euclidean, cosine, Mahalanobis metrics) and with low predictive entropy are integrated. The model is then incrementally retrained with these images under strict performance safeguards (no metric degradation >5%). In experiments with a ResNet18 ensemble on a multi-center dataset, the framework prevents performance degradation: new images were added without significant change in AUC (~0.92) or accuracy (~89%). This approach addresses data shift and avoids catastrophic forgetting, enabling sustained learning in medical imaging AI.

Figures & tables

Explore similar work

Apr 6, 2026

Learning, Potential, and Retention: An Approach for Evaluating Adaptive AI-Enabled Medical Devices

This work addresses challenges in evaluating adaptive artificial intelligence (AI) models for medical devices, where iterative updates to both models and evaluation datasets complicate performance assessment. We introduce a novel approach with three complementary measurements: learning (model improvement on current data), potential (dataset-driven performance shifts), and retention (knowledge preservation across modification steps), to disentangle performance changes caused by model adaptations versus dynamic environments. Case studies using simulated population shifts demonstrate the approach's utility: gradual transitions enable stable learning and retention, while rapid shifts reveal trade-offs between plasticity and stability. These measurements provide practical insights for regulatory science, enabling rigorous assessment of the safety and effectiveness of adaptive AI systems over sequential modifications.
Mar 20, 2026

AEGIS: An Operational Infrastructure for Post-Market Governance of Adaptive Medical AI Under US and EU Regulations

Machine learning systems deployed in medical devices require governance frameworks that ensure safety while enabling continuous improvement. Regulatory bodies including the FDA and European Union have introduced mechanisms such as the Predetermined Change Control Plan (PCCP) and Post-Market Surveillance (PMS) to manage iterative model updates without repeated submissions. This paper presents AI/ML Evaluation and Governance Infrastructure for Safety (AEGIS), a governance framework applicable to any healthcare AI system. AEGIS comprises three modules, i.e., dataset assimilation and retraining, model monitoring, and conditional decision, that operationalize FDA PCCP and EU AI Act Article 43(4) provisions. We implement a four-category deployment decision taxonomy (APPROVE, CONDITIONAL APPROVAL, CLINICAL REVIEW, REJECT) with an independent PMS ALARM signal, enabling detection of the critical state in which no deployable model exists while the released model is simultaneously at risk. To illustrate how AEGIS can be instantiated across heterogeneous clinical contexts, we provide two examples: sepsis prediction from electronic health records and brain tumor segmentation from medical imaging. Both cases use identical governance architecture, differing only in configuration. Across 11 simulated iterations on the sepsis example, AEGIS yielded 8 APPROVE, 1 CONDITIONAL APPROVAL, 1 CLINICAL REVIEW, and 1 REJECT decision, exercising all four categories. ALARM signals were co-issued at iterations 8 and 10, including the critical state where no deployable model exists and the released model is simultaneously failing. AEGIS detected drift before observable performance degradation. These results demonstrate that AEGIS translates regulatory change-control concepts into executable governance procedures, supporting safe continuous learning for adaptive medical AI across diverse clinical applications.
May 11, 2026

GenMed: A Pairwise Generative Reformulation of Medical Diagnostic Tasks

Data-driven medical AI is traditionally formulated as a discriminative mapping from input XX to output YY via a learned function ff, which does not generalize well across heterogeneous data and modalities encountered in real-world clinical settings. In this work, we propose a fundamentally different, generative paradigm. We model the joint distribution P(X,Y)P(X,Y) using diffusion models and reframe inference as a test-time output optimization problem. By guiding the generative process to match observed inputs, our framework enables flexible, gradient-based conditioning at inference time without architectural changes or retraining, effectively supporting arbitrary and previously unseen combinations of observations. Extensive experiments demonstrate strong performance across standard and cross-modality medical image segmentation, few-shot segmentation with only 2 or 4 training samples, degraded-input segmentation, shape completion from sparse and partial observations, and zero-shot application to demonstrate generality. To support these evaluations, we curated and released a large-scale text-shape dataset derived from MedShapeNet. Our results highlight the versatility of generative joint modeling as a foundation for reusable, task-agnostic medical AI systems.