cs.CVApr 13, 2026

ConvFormer3D-TAP: Phase/Uncertainty-Aware Front-End Fusion for Cine CMR View Classification Pipelines

Authors: Nafiseh Ghaffar Nia, Vinesh Appadurai, Suchithra V., Chinmay Rane, Daniel Pittman, James Carr, Adrienne Kline

Organizations: Center for Artificial Intelligence, Bluhm Cardiovascular Institute, Northwestern Medicine, Chicago, IL, USA · Department of Electrical and Computer Engineering, Northwestern University, Chicago, IL, USA · Department of Surgery, Northwestern University, Chicago, IL, USA · Department of Radiology, Northwestern University, Chicago, IL, USA; and Xtasis Inc., Chicago, IL, USA · Department of Cardiology, The Prince Charles Hospital; and School of Medicine, The University of Queensland, Queensland, Australia · Quantiphi Inc., USA

Abstract

Reliable recognition of standard cine cardiac MRI views is essential because each view determines which cardiac anatomy is visualized and which quantitative analyses can be performed. Incorrect view identification, whether by a human reader or an automated deep learning system, can propagate errors into segmentation, volumetric assessment, strain analysis, and valve evaluation. However, accurate view classification remains challenging under routine clinical variability in scanner vendor, acquisition protocol, motion artifacts, and plane prescription. We present ConvFormer3D-TAP, a cine-specific spatiotemporal architecture that integrates 3D convolutional tokenization with multiscale self-attention. The model is trained using masked spatiotemporal reconstruction and uncertainty-weighted multi-clip fusion to enhance robustness across cardiac phases and ambiguous temporal segments. The design captures complementary cues: local anatomical structure through convolutional priors and long-range cardiac-cycle dynamics through hierarchical attention. On a cohort of 150,974 clinically acquired cine sequences spanning six standard cine cardiac MRI views, ConvFormer3D-TAP achieved 96% validation accuracy with per-class F1-scores >= 0.94 and strong calibration (ECE = 0.025; Brier = 0.040). Error analysis shows that residual confusions are concentrated in anatomically adjacent long-axis and LVOT/AV view pairs, consistent with intrinsic prescription overlap. These results support ConvFormer3D-TAP as a scalable front-end for view routing, filtering and quality control in end-to-end cMRI workflows.

Figures & tables

Explore similar work

Jun 3, 2026

Motion-Guided Causal Disentanglement for Robust Multi-View Cine Cardiac MRI Diagnosis

Multi-view cardiac magnetic resonance (CMR) imaging provides complementary anatomical information and is widely used for noninvasive disease assessment. Recent transformer-based models have demonstrated strong representation learning capabilities for CMR analysis; however, they typically learn unified latent embeddings that entangle view-specific anatomical variations with disease-related features. Such entanglement biases classifiers toward structural attributes rather than view-invariant pathological patterns. This issue is exacerbated in low-data regimes, particularly for underrepresented cardiac conditions, where limited samples increase the susceptibility to shortcut learning and view-dependent decision boundaries. To address this, we propose a Motion-Guided View--Disease Disentanglement framework MoViD built upon a ViT-MAE backbone. The model explicitly factorizes latent representations into view-specific and disease-discriminative components using dual-branch supervised contrastive objectives and a gradient-reversal adversarial constraint that minimizes disease leakage into the view embedding. Additionally, an annotation-free temporal motion feature, derived from inter-frame difference maps, is introduced to localize the beating heart region and suppress background artifacts. A focal reweighting mechanism is incorporated into the contrastive loss to mitigate class imbalance. We evaluate the framework on a private clinical venous thrombosis dataset and two public benchmarks (M&Ms, M&Ms2). Across disease classification and cardiac segmentation tasks, our approach consistently outperforms standard transformer baselines and demonstrates competitive performance against large-scale pretrained foundation models, validating the efficacy of structural disentanglement in medical image analysis.
Jun 16, 2026

Spatio-Temporal Fusion Model for Standard View Classification of Echocardiographic Videos

Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges. First, publicly available datasets are scarce and limited in scale and view coverage. Second, the performance of some modern video-level architectures for echocardiographic view classification remains underexplored. Third, some view categories exhibit highly similar spatial appearances, making single-frame features insufficient for discrimination, while heterogeneous frame quality complicates robust temporal information fusion. To address these challenges, we release the Echocardiographic Videos of Nine Views (EV9V) dataset, comprising 5,138 videos, 910,579 frames, and 9 standard views, which is, to the best of our knowledge, the largest publicly available echocardiography video dataset. Using EV9V, we systematically benchmark representative video classification architectures, including Convolutional Neural Networks (CNNs), Recurrent Neural Networks (RNNs), and Transformers. Furthermore, we propose a Spatio-Temporal Fusion Model (STFM), an efficient dual-stream CNN-LSTM (Long Short-Term Memory) framework that jointly captures spatial anatomical structures and temporal cardiac dynamics. The proposed framework leverages uncertainty-aware learning to preferentially sample representative video segments during training and evidence-based fusion during inference, improving robustness to variations in frame quality across echocardiographic videos. Extensive experiments demonstrate that our method achieves competitive performance across diverse video classification models, validating the effectiveness of uncertainty-aware spatio-temporal learning for echocardiographic view classification. The code is available at https://github.com/bgx666/stfm.
Sep 1, 2026

CMRVision: A Foundation Model for Cardiac MR Image Analysis

Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.