Performance Characterization of Frequency-Selective Wireless Power Transfer Toward Scalable Untethered Magnetic Actuation
Organizations: Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, USA · Department of Mechanical Engineering, Texas Tech University, Lubbock, USA
Abstract
Frequency-selective wireless power transfer provides a feasible route to enable independent actuation and control of multiple untethered robots in a common workspace; however, the scalability remains unquantified, particularly the maximum number of resonators that can be reliably addressed within a given frequency bandwidth. To address this, we formulate the relationship between resonator quality factor (Q-factor) and the number of individually addressable inductor-capacitor (LC) resonant energy harvesters within a fixed radio-frequency (RF) spectrum, and we convert selectively activated harvested energy into mechanical motion. We theoretically proved and experimentally demonstrated that scalability depends primarily on the Q-factor. For this proof-of-concept study, we define effective series resistance as a function of frequency allocating bandwidths to discrete actuators. We provide design equations for scaling untethered magnetic actuation with Q-factor optimization. Resonator networks spanning bandwidths from 100kHz to 1MHz were analyzed to quantify how increasing the number of resonators affects independent addressability. We validated the approach experimentally by fabricating three centimeter-scale untethered actuators that selectively trigger the motion of mechanical beams at 734kHz, 785kHz, and 855kHz. We also characterized the generated mechanical force and the activation bandwidth of each actuator, confirming that no unintended cross-triggering occurred.
Figures & tables
| Designator | Specification |
| C1 | (C0G/NP0) |
| L1, L2 | |
| C2 | , , (C0G/NP0) |
| C3 | |
| D1, D2 | BAV21WSA |
| C4 |
| L | C | Measured | Expected | Measured | Q-Factor | ( ) | |
| Charging LC1 | 10.0 | 2.0 | 20 | 1.125 MHz | 1.140 MHz | 57.00 | 14.89 |
| Charging LC2 | 10.0 | 2.0 | 20 | 1.125 MHz | 1.104 MHz | 55.20 | 14.06 |
| Charging LC3 | 10.0 | 2.0 | 20 | 1.125 MHz | 1.120 MHz | 56.00 | 14.44 |
| Trigger LC1 | 10.0 | 4.7 | 60 | 734 kHz | 734 kHz | 12.23 | 5.29 |
| Trigger LC2 | 10.0 | 3.9 | 55 | 806 kHz | 785 kHz | 14.27 | 4.39 |
| Trigger LC3 | 10.0 | 3.3 | 60 | 876 kHz | 855 kHz | 14.25 | 3.81 |
Robotics
Robotics studies the design and control of machines that perceive, move, and act in physical environments.
See all 751 papers