cs.CVApr 13, 2026

MosaicMRI: A Diverse Dataset and Benchmark for Raw Musculoskeletal MRI

Authors: Paula Arguello, Berk Tinaz, Mohammad Shahab Sepehri, Maryam Soltanolkotabi, Mahdi Soltanolkotabi

Organizations: Department of Computer Science, University of Southern California · USC Center on AI Foundations for the Sciences · Department of Electrical and Computer Engineering, University of Southern California · Department of Radiology and Imaging Sciences, University of Utah

Abstract

Deep learning underpins a wide range of applications in MRI, including reconstruction, artifact removal, and segmentation. However, progress has been driven largely by public datasets focused on brain and knee imaging, shaping how models are trained and evaluated. As a result, careful studies of the reliability of these models across diverse anatomical settings remain limited. In this work, we introduce MosaicMRI, a large and diverse collection of fully sampled raw musculoskeletal (MSK) MR measurements designed for training and evaluating machine-learning--based methods. MosaicMRI is the largest open-source raw MSK MRI dataset to date, comprising 3,150 volumes and 89,830 slices, including a 3,096-volume 1.5T core dataset and a 54-volume 0.55T low-field set. The dataset offers substantial diversity in volume orientation (e.g., axial, sagittal), imaging contrasts (e.g., PD, T1, T2), anatomies (e.g., spine, knee, hip, ankle, and others), numbers of acquisition coils, and field strengths. Using accelerated reconstruction as a testbed, we study scaling, robustness, and data selection under realistic MSK distribution shifts. Across E2E-VarNet, U-Net, and ViT baselines, mixed-anatomy training improves over anatomy-specific training, showing that the benefit of anatomical diversity is not architecture-specific. Zero-shot experiments on the 0.55~T low-field set highlight that using more training data improves average reconstruction under field-strength shift. Controlled subset experiments further suggest that these gains come from transferable cross-anatomy structure, rather than anatomy or contrast matching alone.

Figures & tables

Appendix figures & tables5 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Feb 24, 2026

OrthoDiffusion: A Generalizable Multi-Task Diffusion Foundation Model for Musculoskeletal MRI Interpretation

Musculoskeletal disorders represent a significant global health burden and are a leading cause of disability worldwide. While MRI is essential for accurate diagnosis, its interpretation remains exceptionally challenging. Radiologists must identify multiple potential abnormalities within complex anatomical structures across different imaging planes, a process that requires significant expertise and is prone to variability. We developed OrthoDiffusion, a unified diffusion-based foundation model designed for multi-task musculoskeletal MRI interpretation. The framework utilizes three orientation-specific 3D diffusion models, pre-trained in a self-supervised manner on 15,948 unlabeled knee MRI scans, to learn robust anatomical features from sagittal, coronal, and axial views. These view-specific representations are integrated to support diverse clinical tasks, including anatomical segmentation and multi-label diagnosis. Our evaluation demonstrates that OrthoDiffusion achieves excellent performance in the segmentation of 11 knee structures and the detection of 8 knee abnormalities. The model exhibited remarkable robustness across different clinical centers and MRI field strengths, consistently outperforming traditional supervised models. Notably, in settings where labeled data was scarce, OrthoDiffusion maintained high diagnostic precision using only 10% of training labels. Furthermore, the anatomical representations learned from knee imaging proved highly transferable to other joints, achieving strong diagnostic performance across 11 diseases of the ankle and shoulder. These findings suggest that diffusion-based foundation models can serve as a unified platform for multi-disease diagnosis and anatomical segmentation, potentially improving the efficiency and accuracy of musculoskeletal MRI interpretation in real-world clinical workflows.
Oct 9, 2026

A4-MR: Abnormality-aware Anatomical Alignment for MR

Recent advances in large-scale foundation models have enabled strong generalization across a wide range of clinical and research tasks in magnetic resonance imaging (MRI). However, existing vision-language MRI models remain limited in anatomy-specific localization and pathology-aware representation, particularly in real-world settings. We introduce A4-MR, a 3D vision-language foundation model trained on approximately 50,000 MRI studies comprising 491,000 series, roughly half of which are paired with radiology reports. A4-MR is designed to: (1) learn anatomy localization through large-scale pretraining with noisy labels; (2) align image and text representations at the anatomical level; and (3) learn distinct representations of healthy and abnormal anatomy. Across a diverse set of downstream tasks, A4-MR outperforms existing foundation models, including a +1.7 AUROC improvement over MedSigLIP for abnormality detection. Using a frozen encoder, A4-MR also surpasses an end-to-end task-specific MedNeXt model for knee segmentation by +1.4 Dice and performs comparably to the best task-specific model for abdominal organ segmentation on AMOS, within 0.4 Dice. Finally, without anatomical prompts, A4-MR localizes 3D anatomy comparably to MedSAM2 provided with ground-truth bounding boxes. Together, these results demonstrate that anatomy-level multimodal alignment and abnormality-aware representation learning can enable a single MRI foundation model to support localization, segmentation, and pathology-related tasks.
Sep 25, 2026

KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning

Background: Large volumes of unlabeled knee MRI scans are available across repositories but remain insufficiently leveraged. We developed KneePreM, a knee-specific 3D self-supervised model, and evaluated transfer and label efficiency for classification and segmentation. Methods: A 3D U-Net masked autoencoder was pretrained on 19,011 unlabeled Osteoarthritis Initiative (OAI) MRI series from 4,791 participants. Downstream fine-tuning used full and reduced training sets for fastMRI+ two-label classification (1,172 examinations), Arthroscopic Partial Meniscectomy (APM) eight-target classification (1,716 examinations), SKM-TEA segmentation (155 examinations), and APM segmentation (25 examinations). Baselines were random initialization and SuPreM. Deployment workflow was implemented with a Model Context Protocol interface. Evaluation metrics included balanced accuracy, F1 score, ROC AUC, PR AUC, and Dice score. Statistical analysis used bootstrap confidence intervals and paired bootstrap tests for classification and Wilcoxon signed-rank tests for segmentation. Results: KneePreM achieved higher full-data macro ROC AUC than both baselines for fastMRI+ and APM (all p < .001). For fastMRI+ classification, KneePreM achieved a ROC AUC of 0.722 using 50% of the training data, exceeding both full-data baselines. In APM classification, KneePreM reached a ROC AUC of 0.740 with 70% of the data, matching the full-data random baseline and outperforming SuPreM. For SKM-TEA segmentation, its 70%-data Dice of 0.838 exceeded the full-data random baseline (0.835) and both same-budget comparators. In APM segmentation, its 75%-data Dice of 0.746 exceeded the full-data random baseline (0.731) and both same-budget comparators. Conclusion: KneePreM improves transfer performance and label efficiency across knee MRI classification and segmentation tasks, particularly when labeled training data are limited.