cs.CVSep 25, 2026

KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning

Authors: Xinxin Wang, Liam Hazan, Jing Li, Simona Rabinovici-Cohen, Xiaojuan Li, Mingrui Yang

Organizations: Program of Advanced Musculoskeletal Imaging, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, United States · Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, United States · Department of Computer and Data Science, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, United States · IBM Research Labs, IBM Research, Haifa University Campus, Mount Carmel, Haifa 3498825, Israel · Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, United States

Abstract

Background: Large volumes of unlabeled knee MRI scans are available across repositories but remain insufficiently leveraged. We developed KneePreM, a knee-specific 3D self-supervised model, and evaluated transfer and label efficiency for classification and segmentation. Methods: A 3D U-Net masked autoencoder was pretrained on 19,011 unlabeled Osteoarthritis Initiative (OAI) MRI series from 4,791 participants. Downstream fine-tuning used full and reduced training sets for fastMRI+ two-label classification (1,172 examinations), Arthroscopic Partial Meniscectomy (APM) eight-target classification (1,716 examinations), SKM-TEA segmentation (155 examinations), and APM segmentation (25 examinations). Baselines were random initialization and SuPreM. Deployment workflow was implemented with a Model Context Protocol interface. Evaluation metrics included balanced accuracy, F1 score, ROC AUC, PR AUC, and Dice score. Statistical analysis used bootstrap confidence intervals and paired bootstrap tests for classification and Wilcoxon signed-rank tests for segmentation. Results: KneePreM achieved higher full-data macro ROC AUC than both baselines for fastMRI+ and APM (all p < .001). For fastMRI+ classification, KneePreM achieved a ROC AUC of 0.722 using 50% of the training data, exceeding both full-data baselines. In APM classification, KneePreM reached a ROC AUC of 0.740 with 70% of the data, matching the full-data random baseline and outperforming SuPreM. For SKM-TEA segmentation, its 70%-data Dice of 0.838 exceeded the full-data random baseline (0.835) and both same-budget comparators. In APM segmentation, its 75%-data Dice of 0.746 exceeded the full-data random baseline (0.731) and both same-budget comparators. Conclusion: KneePreM improves transfer performance and label efficiency across knee MRI classification and segmentation tasks, particularly when labeled training data are limited.

Explore similar work

May 9, 2026

Reducing Annotation Burden for Femoral Cartilage Segmentation in Knee MRI via Cross-Sequence Transfer Learning

Purpose: To develop and evaluate cross-sequence transfer learning for automatic femoral cartilage segmentation, testing bidirectional transfer between dual-echo steady-state (DESS) and sagittal proton density-weighted 3D fast spin-echo (Cube) sequences. Materials and Methods: We optimized a modified 2D U-Net on 507 DESS images from the Osteoarthritis Initiative (OAI). We then established same-sequence baselines using subject-level cross-validation on a subset of 44 OAI DESS images and 44 Cube images acquired at the Istituto Ortopedico Rizzoli, Bologna, Italy. Each subset included 22 non-lesioned and 22 lesioned subjects. Finally, we performed transfer learning across sequences by fine-tuning the pretrained models on the target sequence with increasing training set sizes to study convergence, while keeping validation and test sets fixed. Segmentations were evaluated using Dice similarity coefficient (DSC) and average surface distance (ASD). Lesion effects were assessed with two-sided Mann-Whitney U tests with Bonferroni correction. Results: Same-sequence training yielded higher accuracy on DESS than Cube (DSC, 0.9000.900 vs 0.8300.830; P<.001P < .001). Cube-to-DESS transfer matched DESS performance (DSC, 0.903±0.0320.903 \pm 0.032 vs 0.900±0.0270.900 \pm 0.027), reaching a performance plateau at 9 training subjects. DESS-to-Cube yielded a lower combined DSC (0.802±0.0490.802 \pm 0.049 vs 0.830±0.0420.830 \pm 0.042), reaching a plateau at 24 training subjects. Lesions did not affect DESS (P≥.39P \ge .39) but reduced Cube accuracy (DSC, 0.8050.805 vs 0.8560.856; P<.001P < .001). Conclusion: Transfer learning across sequences can substantially reduce target-sequence annotation requirements for femoral cartilage segmentation, but performance is direction- and sequence-dependent, and the effects of lesions on segmentation may vary across MRI sequences.
Oct 6, 2026

Knee3DVLM: Dual-Sequence Full-Volume Vision-Language Modeling for Comprehensive Knee MRI Assessment

Vision-language models (VLMs) are increasingly being applied to three-dimensional medical imaging, but their application to knee MRI remains limited, particularly for interpreting the complementary sequences used in clinical practice. We introduce Knee3DVLM, a sequence-aware VLM that uses full-volume DESS and fluid-sensitive TSE MRI to predict 57 anatomically resolved binary diagnostic targets derived from the MRI Osteoarthritis Knee Score (MOAKS) for structured reporting. We evaluated DESS-only, TSE-only, and paired DESS-TSE configurations using subject-disjoint Osteoarthritis Initiative partitions. In a held-out cohort of 1,074 examinations, the fused model achieved 72.98% average accuracy, 71.17% balanced accuracy, 78.96% mean ROC-AUC, and 78.74% macro ROC-AUC, the highest values among the three configurations. In a secondary multiclass analysis aligned with the released 3DReasonKnee cohort, Knee3DVLM was numerically higher than the strongest reported 3DReasonKnee configuration across five pathology categories. These findings support dual-sequence full-volume modeling for comprehensive knee MRI assessment.
Jul 2, 2026

Self-Auditing Residual Drifting for Pathology-Preserving Accelerated Knee MRI

Accelerated magnetic resonance imaging reduces acquisition time, but reconstruction from undersampled k-space can blur diagnostically relevant structures or introduce failures that are not captured by global image metrics. We propose SA-RDM-DC, a Self-Auditing Residual generative Drifting Model with Data Consistency for accelerated knee MRI. The method adapts the newly proposed generative drifting paradigm to accelerated MRI by training a physics-conditioned drift field from the zero-filled reconstruction toward the fully sampled residual correction. It predicts image- and missing-k-space residual corrections, enforces data consistency with acquired k-space, uses frequency-aware and residual drifting supervision to recover fine detail, and produces dense error maps and slice-level risk scores in the same inference pass. We evaluate SA-RDM-DC on multi-coil fastMRI knee data at acceleration factors of 4, 8, and 12, with fastMRI+ pathology annotations for region-level and classifier-based task preservation, and on SKM-TEA for zero-shot and fine-tuned protocol-shift evaluation. Compared with zero-filled reconstruction, UNet-image-SENSE, DC-UNet, Score-Diffusion, ELF-Diff, SENSE-VarNet, and MoDL baselines, SA-RDM-DC achieves the highest SSIM across fastMRI acceleration factors while retaining subsecond per-slice inference and avoiding the long sampling time of iterative diffusion baselines. In pathology-aware analysis, SA-RDM-DC preserves lesion-region structural fidelity and reduces meniscus prediction instability. Its self-auditing scores strongly identify high-error reconstructions on fastMRI and partially transfer as a selective-review signal under SKM-TEA protocol shift. These results support reconstruction evaluation that jointly considers image fidelity, pathology preservation, runtime, and case-specific reliability.