physics.med-phApr 14, 2026

DoseRAD2026 Challenge dataset: AI accelerated photon and proton dose calculation for radiotherapy

Authors: Fan Xiao, Nikolaos Delopoulos, Niklas Wahl, Lennart Volz, Lina Bucher, Matteo Maspero, Miguel Palacios, Muheng Li, 

Organizations: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany · Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany · National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany · GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Darmstadt, Germany · 

Abstract

Purpose: Accurate dose calculation is essential in radiotherapy for precise tumor irradiation while sparing healthy tissue. With the growing adoption of MRI-guided and real-time adaptive radiotherapy, fast and accurate dose calculation on CT and MRI is increasingly needed. The DoseRAD2026 dataset and challenge provide a public benchmark of paired CT and MRI data with beam-level photon and proton Monte Carlo dose distributions for developing and evaluating advanced dose calculation methods. Acquisition and validation methods: The dataset comprises paired CT and MRI from 115 patients (75 training, 40 testing) treated on an MRI-linac for thoracic or abdominal lesions, derived from the SynthRAD2025 dataset. Pre-processing included deformable image registration, air-cavity correction, and resampling. Ground-truth photon (6 MV) and proton dose distributions were computed using open-source Monte Carlo algorithms, yielding 40,500 photon beams and 81,000 proton beamlets. Data format and usage notes: Data are organized into photon and proton subsets with paired CT-MRI images, beam-level dose distributions, and JSON beam configuration files. Files are provided in compressed MetaImage (.mha) format. The dataset is released under CC BY-NC 4.0, with training data available from April 2026 and the test set withheld until March 2030. Potential applications: The dataset supports benchmarking of fast dose calculation methods, including beam-level dose estimation for photon and proton therapy, MRI-based dose calculation in MRI-guided workflows, and real-time adaptive radiotherapy.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 4, 2026

BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction

To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation via sub-pixel phase packing, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated by a patch-based conditional GAN with a SwinUNETR backbone. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.
May 13, 2026

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8±21.364.8\pm21.3 HU, PSNR ∼\sim30 dB, MS-SSIM ∼\sim0.936, Dice 0.79, photon γ2%/2mm>98%γ_{2\%/2\text{mm}}>98\%, proton γ≈85%γ\approx85\%. Task 2 improved: MAE 48.3±13.448.3\pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%γ>99\%, proton γ≈89%γ\approx89\%. Strong image--segmentation correlations (ρ=0.78ρ=0.78--0.790.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.
Sep 1, 2026

PyDoseRT Proton: A GPU Pencil-Beam Engine with a Convolutional Residual-Correction Network for Fast Proton Dose Calculation

Architecture category. Hybrid method: a physics-based analytical pencil-beam (PB) dose engine followed by a 3-D convolutional residual-correction network (RepVGG-U-Net). We addressed the DoseRAD2026 proton dose-prediction task with PyDoseRT Proton, a GPU-accelerated engine implemented in PyTorch and augmented by a learned residual toward Monte Carlo (MC) accuracy. A double-Gaussian PB kernel was calibrated to GATE/Geant4 integrated depth doses in water in two stages: a classical per-energy curve fit, then a gradient-based fit of the full 3-D dose through the PyTorch physics engine as it retains a differentiable execution path for gradient-based optimization of dose-dependent objectives. The engine computes each beamlet on a beam's-eye-view (BEV) lattice with variance-preserving Gaussian splitting, an analytic nuclear halo, and a Fermi-Eyges heterogeneity term, then rotates the result into the patient frame. Additionally, a compact residual U-Net predicts an additive correction in BEV space. It is conditioned on voxelwise material-label embeddings, a discrete energy embedding and spot size. The same model was used for all anatomical sites (thoracic and abdominal). It was trained with a patient-space L1 objective emphasizing the scored high-dose region and multi-scale BEV deep supervision. The submitted CT configuration obtained preliminary-test beamlet MAE 0.0066, image-z IDD distance 0.0025, plan MAE 0.0049, 98.30% gamma pass rate (1%/1 mm), and DVH error 0.460.