physics.med-phSep 1, 2026

PyDoseRT Proton: A GPU Pencil-Beam Engine with a Convolutional Residual-Correction Network for Fast Proton Dose Calculation

Authors: Lukas ZimmermannHermann FuchsAttila SimkóGerd Heilemann

Organizations: Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria · Christian Doppler Laboratory for Image and Knowledge Driven Precision Radiation Oncology, Medical University of Vienna, Vienna, Austria · Department of Diagnostics and Intervention, Umeå University, Umeå, Sweden

Abstract

Architecture category. Hybrid method: a physics-based analytical pencil-beam (PB) dose engine followed by a 3-D convolutional residual-correction network (RepVGG-U-Net). We addressed the DoseRAD2026 proton dose-prediction task with PyDoseRT Proton, a GPU-accelerated engine implemented in PyTorch and augmented by a learned residual toward Monte Carlo (MC) accuracy. A double-Gaussian PB kernel was calibrated to GATE/Geant4 integrated depth doses in water in two stages: a classical per-energy curve fit, then a gradient-based fit of the full 3-D dose through the PyTorch physics engine as it retains a differentiable execution path for gradient-based optimization of dose-dependent objectives. The engine computes each beamlet on a beam's-eye-view (BEV) lattice with variance-preserving Gaussian splitting, an analytic nuclear halo, and a Fermi-Eyges heterogeneity term, then rotates the result into the patient frame. Additionally, a compact residual U-Net predicts an additive correction in BEV space. It is conditioned on voxelwise material-label embeddings, a discrete energy embedding and spot size. The same model was used for all anatomical sites (thoracic and abdominal). It was trained with a patient-space L1 objective emphasizing the scored high-dose region and multi-scale BEV deep supervision. The submitted CT configuration obtained preliminary-test beamlet MAE 0.0066, image-z IDD distance 0.0025, plan MAE 0.0049, 98.30% gamma pass rate (1%/1 mm), and DVH error 0.460.

Explore similar work

Aug 10, 2026cs.CV

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.
Zerun Zhang, Xiaoda Cong, Xiangkun Xu +2
Aug 1, 2026physics.med-ph

Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration

Head-and-neck (HN) proton therapy is highly sensitive to anatomical change over a 4-to-6-week course, as tumor shrinkage, weight loss, and setup variation can misposition the Bragg peak near critical organs such as the parotids, oral cavity, brainstem, and spinal cord, leading to target underdosing or organ-at-risk overdosing. Online adaptive proton therapy replans on the anatomy of the day, yet standard workflows rely on offline replanning that requires repeated CT acquisition and roughly a week of preparation, adding burden, cost, and delay. We investigate whether a patient's treatment-day anatomy can be predicted before image acquisition by transferring longitudinal change from a population database. We propose a digital-twin framework built on a pretrained foundation-model deformable registration network used without patient-specific training. A first registration aligns a prior patient's planning CT to the target and carries the prior's during-treatment quality assurance CT (QACT) into the target frame; a second registration estimates the prior's planning-to-QACT change, which is then applied to the target's own planning CT to synthesize predicted CTs (pdCTs) with propagated contours. Using 88 HN patients, each with a planning CT and three QACTs, we show that pdCTs better match treatment-day anatomy than the static planning CT. Compared with the planning CT alone, normalized cross-correlation improves by 22.8%, Dice for organs-at-risk by 20.2%, and CT-number error decreases by 23.4%. Gains are largest for patients with major anatomical change and negligible when anatomy is stable. This cross-patient motion transfer leverages the digital-twin concept to anticipate treatment-day anatomy, enabling personalized online adaptive proton therapy without repeated imaging.
Yizhou Wu, Yuheng Li, Xiaofeng Yang +1
May 10, 2026cs.CV

Any2Any 3D Diffusion Models with Knowledge Transfer: A Radiotherapy Planning Study

Voxel-wise dose prediction is a critical yet challenging task in practical radiotherapy (RT) planning, as bespoke models trained from scratch often struggle to generalize across diverse clinical settings. Meanwhile, generative models trained on billion-scale datasets from vision domains have achieved impressive performance. Herein, we propose DiffKT3D, a unified Any2Any 3D diffusion framework that leverages prior knowledge from pretrained video diffusion models for efficient and clinically meaningful dose prediction. To enable flexible conditioning across multiple clinical modalities (CT, anatomical structures, body, beam settings, etc.), we introduce an Any2Any conditional paradigm utilizing modality-specific embeddings without cross-attention overhead. Further, we design a novel reinforcement learning (RL) post-training mechanism guided by a clinically-informed Scorecard explicitly tailored to institutional treatment preferences. Compared with winner of GDP-HMM challenge, DiffKT3D sets a new state-of-the-art in dose prediction by reducing voxel-level MAE from 2.07 to 1.93. In addition, DiffKT3D achieves superior image quality and preference match. These results demonstrate that transferring diffusion priors via modality-aware conditioning and clinically aligned RL post-training can provide a robust and generalizable solution for RT planning across various clinical scenarios.
Yuhan Wang, Zihan Li, Han Liu +7