cs.CVApr 14, 2026

Representation geometry shapes task performance in vision-language modeling for CT enterography

Authors: Cristian Minoccheri, Emily Wittrup, Kayvan Najarian, Ryan Stidham

Organizations: Gilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, 1109 Geddes Avenue, Ann Arbor, 48104, MI, USA. · Department of Emergency Medicine, University of Michigan, 1109 Geddes Avenue, Ann Arbor, 48104, MI, USA. · Department of Electrical Engineering and Computer Science, University of Michigan, 1109 Geddes Avenue, Ann Arbor, 48104, MI, USA. · Department of Gastroenterology, University of Michigan, 1109 Geddes Avenue, Ann Arbor, 48104, MI, USA.

Abstract

Computed tomography (CT) enterography is a primary imaging modality for assessing inflammatory bowel disease (IBD), yet the representational choices that best support automated analysis of this modality are unknown. We present the first study of vision-language transfer learning on abdominal CT enterography and identify two main findings. First, mean pooling of slice embeddings gives better categorical disease assessment (59.2% three-class accuracy), whereas attention pooling gives better cross-modal retrieval (0.235 text-to-image MRR). This pattern holds across all LoRA configurations tested and suggests that the two aggregators emphasize different properties of the learned representation. Second, per-slice tissue contrast matters more than broader spatial coverage: multi-window RGB encoding, which maps complementary Hounsfield Unit windows to RGB channels, outperforms all strategies that increase spatial coverage through multiplanar sampling, and in this setting adding coronal and sagittal views reduces classification performance. For report generation, fine-tuning without retrieval context yields within-1 severity accuracy at the prevalence-matched chance level (70.4% vs.\ 71% random), suggesting little learned ordering beyond the class distribution. Retrieval-augmented generation (RAG) improves this across all configurations, scoring 7--14 percentage points above the chance baseline and improving ordinal MAE from 0.98 to 0.80--0.89. A three-teacher pseudolabel framework enables all comparisons without expert annotations. Together, these findings provide the first baselines for this underexplored modality and offer practical guidance for building vision-language systems for volumetric medical imaging.

Figures & tables

Explore similar work

Mar 2, 2026

Learning to Read Where to Look: Disease-Aware Vision-Language Pretraining for 3D CT

Recent 3D CT vision-language models align volumes with reports via contrastive pretraining, but typically rely on limited public data and provide only coarse global supervision. We train a 3D CT vision-language model on 98k report-volume pairs (50k patients) collected at a single hospital, combined with public datasets, using SigLIP-style contrastive pretraining together with prompt-based disease supervision in the shared vision-text embedding space. On CT-RATE, our model achieves state-of-the-art text-to-image retrieval (R@10 31.5 vs. 22.2) and competitive disease classification (AUC 83.8 vs. 83.8), with consistent results on Rad-ChestCT (AUC 77.0 vs. 77.3). We further observe that radiologists routinely reference specific images within their reports (e.g., ``series X, image Y''), linking textual descriptions to precise axial locations. We automatically mine 262k such snippet-slice pairs and introduce the task of intra-scan snippet localization -- predicting the axial depth referred to by a text snippet -- reducing mean absolute error to 36.3 mm at 12 mm feature resolution, compared with 67.0 mm for the best baseline. Adding this localization objective leaves retrieval and classification broadly unchanged within confidence bounds, yielding a single unified model for retrieval, classification, and intra-scan grounding.
Feb 18, 2026

OmniCT: Towards a Unified Slice-Volume LVLM for Comprehensive CT Analysis

Computed Tomography (CT) is one of the most widely used and diagnostically information-dense imaging modalities, covering critical organs such as the heart, lungs, liver, and colon. Clinical interpretation relies on both slice-driven local features (e.g., sub-centimeter nodules, lesion boundaries) and volume-driven spatial representations (e.g., tumor infiltration, inter-organ anatomical relations). However, existing Large Vision-Language Models (LVLMs) remain fragmented in CT slice versus volumetric understanding: slice-driven LVLMs show strong generalization but lack cross-slice spatial consistency, while volume-driven LVLMs explicitly capture volumetric semantics but suffer from coarse granularity and poor compatibility with slice inputs. The absence of a unified modeling paradigm constitutes a major bottleneck for the clinical translation of medical LVLMs. We present OmniCT, a powerful unified slice-volume LVLM for CT scenarios, which makes three contributions: (i) Spatial Consistency Enhancement (SCE): volumetric slice composition combined with tri-axial positional embedding that introduces volumetric consistency, and an MoE hybrid projection enables efficient slice-volume adaptation; (ii) Organ-level Semantic Enhancement (OSE): segmentation and ROI localization explicitly align anatomical regions, emphasizing lesion- and organ-level semantics; (iii) MedEval-CT: the largest slice-volume CT dataset and hybrid benchmark integrates comprehensive metrics for unified evaluation. OmniCT consistently outperforms existing methods with a substantial margin across diverse clinical tasks and satisfies both micro-level detail sensitivity and macro-level spatial reasoning. More importantly, it establishes a new paradigm for cross-modal medical imaging understanding. Our project is available at https://github.com/ZJU4HealthCare/OmniCT.
Jul 31, 2026

Semantically Calibrated Evidence Composition for CT Vision-Language Learning

Learning transferable representations from CT-report pairs requires combining whole-volume context with anatomy-specific evidence. Existing methods typically emphasize either global CT-report alignment or fine-grained anatomy-level correspondence. Global alignment preserves broad study context but leaves the contribution of localized evidence implicit, whereas anatomy-level alignment explicitly grounds local findings but does not specify how independently represented evidence should interact, acquire study-level meaning, and contribute to a global CT representation. To address this gap, we propose SCOPE (Semantic Calibration Of comPosed Evidence), a framework for semantically calibrated evidence composition in CT vision-language learning. Under organ-specific report supervision, mask-guided queries with fixed anatomical identities extract context-aware organ evidence from shared, uncropped volumetric features, while an unrestricted global query retains access to whole-volume context. The global query then drives Local-Global Coupling to compose the organ evidence into a unified evidence representation. The composed evidence is subsequently calibrated using the diagnostic summary, providing study-level semantic supervision beyond local organ descriptions, and is finally integrated as a controlled residual into a context-preserving whole-volume representation aligned with the complete report. This progressive pathway connects localized evidence with study-level semantics without reducing the CT representation to a predefined set of organs. On CT-RATE and RadChestCT, SCOPE achieves macro AUCs of 85.0 and 72.2, respectively, outperforming the previous SOTA by 7.2 and 4.2, while also yielding substantial gains in linear probing and cross-modal retrieval. These results demonstrate the effectiveness of semantically calibrated evidence composition.