CrossPan: A Comprehensive Benchmark for Cross-Sequence Pancreas MRI Segmentation and Generalization
Authors: Linkai Peng, Cuiling Sun, Zheyuan Zhang, Wanying Dou, Halil Ertugrul Aktas, Andrea M Bejar, Elif Keles, Tamas Gonda, +5 more
Organizations: Department of Radiology, Northwestern University, Chicago, USA. · Department of Electrical and Computer Engineering, Northwestern University, Evanston, USA. · Department of Computer Science, Northwestern University, Evanston, USA. · Department of Gastroenterology, New York University, NYC, USA. · Division of Gastroenterology and Hepatology, Mayo Clinic in Florida, Jacksonville, USA. · Department of Computer Science, Johns Hopkins University, Baltimore, USA. · Departments of Gastroenterology and Hepatology, Northwestern University, Chicago, USA.
Abstract
Automatic pancreas segmentation is fundamental to abdominal MRI analysis, yet deep learning models trained on one MRI sequence often fail catastrophically when applied to another-a challenge that has received little systematic investigation. We introduce CrossPan, a multi-institutional benchmark comprising 1,386 3D scans across three routinely acquired sequences (T1-weighted, T2-weighted, and Out-of-Phase) from eight centers. Our experiments reveal three key findings. First, cross-sequence domain shifts are far more severe than cross-center variability: models achieving Dice scores above 0.85 in-domain collapse to near-zero (<0.02) when transferred across sequences. Second, state-of-the-art domain generalization methods provide negligible benefit under these physics-driven contrast inversions, whereas foundation models like MedSAM2 maintain moderate zero-shot performance through contrast-invariant shape priors. Third, semi-supervised learning offers gains only under stable intensity distributions and becomes unstable on sequences with high intra-organ variability. These results establish cross-sequence generalization-not model architecture or center diversity-as the primary barrier to clinically deployable pancreas MRI segmentation. Dataset and code are available at https://crosspan.netlify.app/.
Robust medical image segmentation across imaging modalities is challenging because of large differences in appearance and intensity distributions. Models trained on a single modality often show substantial performance drops when applied to unseen domains. In this work, we develop a unified 3D pancreas segmentation framework that applies domain-adversarial learning to 4,604 heterogeneous CT and MRI scans to learn anatomical representations. A shared nnU-Net encoder-decoder is trained for whole-pancreas segmentation, with a latent domain discriminator encouraging CT-MRI feature alignment. The learned encoder is subsequently transferred to pancreatic head-body-tail segmentation using limited MRI-only subregion annotations. An average Dice score of 87.31% on the in-distribution test set and Dice scores ranging from 84.20% to 88.09% across external OOD datasets were achieved in whole pancreas segmentation. Dice scores of 80.53% on MRI and 83.05% on CT were achieved for downstream subregion segmentation, without using CT subregion annotations. These results demonstrate that a unified anatomical representation can support both cross-modality pancreas segmentation and label-efficient downstream transfer.
Pancreatic tumor segmentation in contrast-enhanced computed tomography (CT) is clinically important yet technically challenging: lesions are often small, heterogeneous, and easily confused with surrounding soft tissue, and models that perform well on one cohort frequently degrade under cohort shift. Our goal is to improve cross-cohort generalization while keeping the model architecture simple, efficient, and practical for 3D CT segmentation. We introduce PanGuide3D, a cohort-robust architecture with a shared 3D encoder, a pancreas decoder that predicts a probabilistic pancreas map, and a tumor decoder that is explicitly conditioned on this pancreas probability at multiple scales via differentiable soft gating. To capture long-range context under distribution shift, we further add a lightweight Transformer bottleneck in the U-Net bottleneck representation. We evaluate cohort transfer by training on the PanTS (Pancreatic Tumor Segmentation) cohort and testing both in-cohort (PanTS) and out-of-cohort on MSD (Medical Segmentation Decathlon) Task07 Pancreas, using matched preprocessing and training protocols across strong baselines. We collect voxel-level segmentation metrics, patient-level tumor detection, subgroup analyses by tumor size and anatomical location, volume-conditioned performance analyses, and calibration measurements to assess reliability. Across the evaluated models, PanGuide3D achieves the best overall tumor performance and shows improved cross-cohort generalization, particularly for small tumors and challenging anatomical locations, while reducing anatomically implausible false positives. These findings support probabilistic anatomical conditioning as a practical strategy for improving cross-cohort robustness in an end-to-end model and suggest potential utility for contouring support, treatment planning, and multi-institutional studies.
Accurate pancreas segmentation is critical for early cancer diagnosis, where annotation scarcity necessitates Semi-Supervised Learning (SSL). However, due to significant inter-sample morphological variability, existing SSL methods face severe generalizability limitations under sparse supervision, leading to the Supervision Bias problem. To address this, we propose Structural Consensus-based KAN Prototype Learning (SCKAN), which constructs the first cross-sample structural consensus learning with Kolmogorov-Arnold Networks (KANs), to achieve more generalizable and accurate segmentation. Specifically, SCKAN contains two key designs: Structure-constrained Prototype Consistency Learning (SPCL), which prompts unbiased structural representation by enforcing cross-sample consistency via prototype-level contrastive optimization, and Consensus-based Kolmogorov-Arnold Fusion (CKaF), which reduces morphology-specific bias by aggregating stable consensus and filtering sample-wise noise via KAN's adaptive B-spline nonlinearity. Extensive experiments on two public pancreas datasets demonstrate the effectiveness of SCKAN. Code is at https://github.com/rhodaliu17/SCKAN.