Abstract
Distribution networks with high penetration of Distributed Energy Resources (DERs) increasingly rely on communication networks to coordinate grid-interactive control. While many distributed control schemes have been proposed, they are often evaluated under idealized communication assumptions, making it difficult to assess their performance under realistic network conditions. This work presents an implementation-driven evaluation of a representative virtual power plant (VPP) dispatch algorithm using a co-simulation framework that couples a linearized distribution-system model with packet-level downlink emulation in ns-3. The study considers a modified IEEE~37-node feeder with high photovoltaic penetration and a primal--dual VPP dispatch that simultaneously targets feeder-head active power tracking and voltage regulation. Communication effects are introduced only on the downlink path carrying dual-variable updates, where per-DER packet delays and a hold-last-value strategy are modeled. Results show that, under ideal communication, the dispatch achieves close tracking of the feeder-head power reference while maintaining voltages within the prescribed limits at selected buses. When realistic downlink delay is introduced, the same controller exhibits large oscillations in feeder-head power and more frequent voltage limit violations. These findings highlight that distributed DER control performance can be strongly influenced by communication behavior and motivate evaluation frameworks that explicitly incorporate network dynamics into the assessment of grid-interactive control schemes.
Explore similar work
Jul 20, 2026cs.MA
This work addresses the need for engineering-grounded evaluation of implement-ed tariff mechanisms in distribution-level energy systems. A digital twin-based method is proposed for assessing local collective tariffs under realistic behavioral and infrastructural conditions. The approach integrates agent-based modeling of household consumption and generation, virtual aggregation through a shared metering abstraction, and explicit representation of tariff logic within a unified simulation environment. The method is demonstrated through its application to the Danish Local Collective Tariff across representative residential energy community configurations, including scenarios with photovoltaic generation, battery storage, and electric vehicle charging. Results indicate that aggregation of heterogeneous demand profiles reduces peak coincidence and enables more efficient allocation of tariff components, leading to measurable cost reductions at the community level. At the same time, the outcomes reveal sensitivity to the temporal alignment of consumption and generation, influencing the degree of cost neutrality across participants. The findings illustrate how digital twin-based evaluation can support systematic assessment of tariff mechanisms by capturing the interaction between infrastructure, user behavior, and regulatory design. The proposed approach provides a basis for analyzing and comparing tariff structures in distribution-level energy systems beyond the specific case considered.
Kristoffer Christensen, Bo Nørregaard Jørgensen, Zheng Grace Ma
Aug 31, 2026eess.SY
Deploying a new control policy for voltage control in active distribution grids requires evidence that physical limits will be satisfied before the policy is tested on the physical grid. This assessment is difficult for two reasons. First, simulations cannot capture every disturbance, modeling error, and device interaction present in the real grid. Second, historical measurements reflect operation under existing control policies, whereas a new policy may drive the grid into different operating conditions. To address these challenges, we propose Distributionally Robust Conformal Safety Screening (DR-CSS), a policy-agnostic framework for pre-deployment, scenario-by-scenario screening of a new control policy using historical data and a nominal simulator. For each new scenario, the simulator predicts a future voltage trajectory for the whole grid; DR-CSS then constructs a conformal safety interval around this prediction using historical simulation-to-reality errors. The interval is further enlarged to account for closed-loop changes induced by the deployment of the new policy and its interactions with the remaining controllers. To the best of our knowledge, DR-CSS is the first framework in power systems to combine historical data from an existing control policy with an imperfect simulator for pre-deployment safety screening of a new policy. Experiments on the IEEE 33-bus and IEEE 141-bus systems evaluate the deployment of learning-based voltage control policies and show that DR-CSS identifies all unsafe test scenarios. To reduce unnecessary warnings on safe scenarios, we adapt the safety intervals to different operating conditions and gradually introduce new policies with recalibration after each stage. These extensions increase the informational value of the safety screening and support safer deployment decisions in active distribution grids.
Sarra Bouchkati, Petros Ellinas, Adriana Geisler +4
Jul 6, 2026cs.LG
Transient stability control in smart grids requires rapid post-fault damping of generator frequency and rotor angle deviations to prevent cascading failures. This paper proposes FedPPO-PG, a Federated Multi-Agent Proximal Policy Optimization framework with Physics-Grounded neighborhoods, which reformulates transient stability control as a cooperative multi-agent reinforcement learning problem optimized directly against closed-loop stability objectives. Each generator hosts an independent local actor augmented with the frequency deviations of its two most strongly coupled electrical neighbors, identified from the post-fault Kron-reduced susceptance matrix. A guided policy initialization phase warm-starts all actors from the classical decentralized controller, while a centralized critic guides advantage estimation under the centralized training--decentralized execution (CTDE) paradigm. Evaluated on a simulation of the IEEE 39-bus benchmark system across five training and three unseen fault contingencies, FedPPO-PG achieves 100% stabilization in all 24 trials, reduces mean stability time by 72.4%, and cuts the control power by 7-14 times compared to the centralized baseline. Each actor executes independently with no central coordinator at deployment, and the per-actor inference latency satisfies the IEEE/IEC 60255-118-1-2018 real-time reporting requirements.