cs.ROApr 22, 2026

A Vision-Language-Action Model for Adaptive Ultrasound-Guided Needle Insertion and Needle Tracking

Authors: Yuelin ZhangQingpeng DingLongxiang TangChengyu FangShing Shin Cheng

Abstract

Ultrasound (US)-guided needle insertion is a critical yet challenging procedure due to dynamic imaging conditions and difficulties in needle visualization. Many methods have been proposed for automated needle insertion, but they often rely on hand-crafted pipelines with modular controllers, whose performance degrades in challenging cases. In this paper, a Vision-Language-Action (VLA) model is proposed for adaptive and automated US-guided needle insertion and tracking on a robotic ultrasound (RUS) system. This framework provides a unified approach to needle tracking and needle insertion control, enabling real-time, dynamically adaptive adjustment of insertion based on the obtained needle position and environment awareness. To achieve real-time and end-to-end tracking, a Cross-Depth Fusion (CDF) tracking head is proposed, integrating shallow positional and deep semantic features from the large-scale vision backbone. To adapt the pretrained vision backbone for tracking tasks, a Tracking-Conditioning (TraCon) register is introduced for parameter-efficient feature conditioning. After needle tracking, an uncertainty-aware control policy and an asynchronous VLA pipeline are presented for adaptive needle insertion control, ensuring timely decision-making for improved safety and outcomes. Extensive experiments on both needle tracking and insertion show that our method consistently outperforms state-of-the-art trackers and manual operation, achieving higher tracking accuracy, improved insertion success rates, and reduced procedure time, highlighting promising directions for RUS-based intelligent intervention.

Explore similar work

Jul 24, 2026cs.RO

Action-Conditioned World Model for Goal Plane Probe Guidance in Robotic Ultrasound

We present an action-conditioned world model framework for goal plane probe guidance in robotic ultrasound, with a focus on neck ultrasound scanning. Autonomous ultrasound tasks often require large numbers of probe-motion trajectories for training, but collecting high-quality demonstrations is labor-intensive and explicit simulators are difficult to build because ultrasound appearance depends on contact, tissue deformation, and view-dependent acoustic artifacts. We address this problem with a two-stage model-based learning pipeline. First, a latent conditional diffusion world model predicts future ultrasound observations from recent context frames, probe motions and temporal offset. Second, a goal-conditioned temporal transformer predicts ordered probe motions and is fine-tuned using rewards from the frozen world model. Experiments on the self-collected dataset show that the world model preserves action-dependent anatomical structure on target-directed scans. In real-world closed loop experiments, the framework achieves success rates of 70.0% for carotid guidance and 65.0% for thyroid guidance. These results demonstrate the potential of learned ultrasound dynamics for training goal-directed robotic probe navigation.
Siqi Fan, Mingcong Chen, Ran Liu +5
Sep 10, 2026cs.RO

RodForesight: A World Model Enhanced Diffusion Policy for Slender Rod Insertion

Slender rod insertion arises in precision manufacturing, where millimetre scale diameter and tight clearances demand accurate perception and control. Conventional peg-in-hole methods assume a rigid object whose tip pose is fixed relative to the gripper. This assumption breaks down for a high aspect ratio rod, which can bend during manipulation, making its tip motion dependent on the rod configuration, grasp, material properties, and contact. We present RodForesight, a learning framework that factorises the task into two stages: 1) coarse approaching, which uses visual servoing to map diverse initial configurations into a compact near hole hand-off region; and 2) predictive insertion, which performs fine alignment and completes the insertion. It is worth noting that the two stages can be wrapped into an end-to-end design. During insertion, a diffusion policy generates candidate action chunks, while an action conditioned world model predicts their effects on rod-hole alignment. This pre-execution evaluation enables RodForesight to select the best action chunk based on predicted tilt and radial errors before execution. Experiments investigate the performance of different stages and the end-to-end setting, where RodForesight improves the success rate from 88.9% to 96.7%, compared to baseline methods such as diffusion policy.
Chuanbo Yu, Mingyu Yue, Yan Lyu +2
Jul 14, 2026cs.CV

Seeing Globally, Refining Locally: Global Visual Guidance and Local Ultrasound Cues for Robust Freehand 3-D Ultrasound Reconstruction

Freehand 3-D ultrasound (US) imaging has attracted increasing attention owing to its intuitive volumetric visualization, ease of use, and low cost. However, accurate 3-D reconstruction critically depends on stable probe pose estimation, yet existing trackerless methods remain susceptible to accumulated pose errors, particularly over long scanning trajectories. To address this limitation, we propose a global-to-local pose estimation framework that exploits external camera observations for globally stable localization and B-mode US images for anatomy-aware local refinement. Specifically, the framework comprises a dual-camera branch that performs contextual feature aggregation across camera views and temporal observations to estimate a globally consistent probe trajectory, and a B-mode branch that performs anatomical feature aggregation from sequential US images to capture tissue-dependent local motion cues. A cross-modal fusion module subsequently integrates the contextual camera features and anatomical US features to predict pose residuals and refine the camera-derived estimates in the transformation space. Furthermore, a multi-scale pose loss constrains relative motion over multiple temporal horizons to suppress accumulated drift during extended scans. The proposed framework is validated on phantom and in vivo datasets. On two in-house datasets (FUSION-J and FUSION-L) collected using different machines, the proposed US + Dual-Cam model reduces average trajectory drift to 1.67 mm and 1.29 mm, representing improvement of 16.50% and 27.12%, respectively, over a strong dual-camera baseline, while substantially outperforming US-only pose estimation (>13 mm drift). In in vivo forearm arteries reconstruction, it achieves Hausdorff distances of 1.58 mm, demonstrating the effectiveness of the proposed method on real clinical scenarios.
Yameng Zhang, Zhongyu Chen, Dianye Huang +3