cs.CVMay 11, 2026

INFANiTE: Implicit Neural representation for high-resolution Fetal brain spatio-temporal Atlas learNing from clinical Thick-slicE MRI

Authors: Xiaotian HuMingxuan LiuHongjia YangTongxi SongYijin LiYifei ChenHaoxiang LiZihan Li+5 more

Organizations: Tsinghua University · University of Oxford · Sichuan University

Abstract

Spatio-temporal fetal brain atlases are important for characterizing normative neurodevelopment and identifying congenital anomalies. However, existing atlas construction pipelines necessitate days for slice-to-volume reconstruction (SVR) to generate high-resolution 3D brain volumes and several additional days for iterative volume registration, thereby rendering atlas construction from large-scale cohorts prohibitively impractical. We address these limitations with INFANiTE, an Implicit Neural Representation (INR) framework for high-resolution Fetal brain spatio-temporal Atlas learNing from clinical Thick-slicE MRI scans, bypassing both the costly SVR and the iterative non-rigid registration steps entirely, thereby substantially accelerating atlas construction. Extensive experiments demonstrate that INFANiTE outperforms existing baselines in subject consistency, reference fidelity, intrinsic quality and biological plausibility, even under challenging sparse-data settings. Additionally, INFANiTE reduces the end-to-end processing time (i.e., from raw scans to the final atlas) from days to hours compared to the traditional 3D volume-based pipeline (e.g., SyGN), facilitating large-scale population-level fetal brain analysis. Code: https://github.com/hu2274898/INFANiTE

Explore similar work

Date pendingphysics.med-ph

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.
Busra Bulut, Maik Dannecker, Thomas Sanchez +14
Jun 9, 2026cs.CV

DD-INR: Dynamics-Driven Implicit Neural Representation for Accelerated Whole-Brain Functional MRI Reconstruction

Accelerated acquisition of fMRI enables enhanced detection of neurovascular (BOLD) activity in the brain, but image reconstruction becomes challenging with high k-space undersampling: Task-evoked BOLD signals are small in magnitude, which traditional anatomical MRI reconstruction methods fail to recover, as they favor spatial accuracy over temporal fidelity. We present DD-INR, a Dynamics-Driven Implicit Neural Representation framework tailored for accelerated fMRI that benefits from incoherent time-varying sampling and a tailored spatiotemporal prior, outperforming traditional methods, demonstrated in simulation and in-vivo acquisition, both in terms of image quality and retrieval of activation patterns. DD-INR achieves this by splitting the fMRI data into a static background and a temporally varying dynamic component, representing only the dynamics with a dedicated INR, thereby focusing the model's capacity on activation-relevant changes while remaining compact. In general, DD-INR provides a promising framework for accelerated fMRI reconstruction, with the potential to improve the sensitivity and robustness of fMRI studies within practical scan time limits. The source code is available at https://github.com/JoosenLi/DD-INR.
Qiaoxin Li, Caini Pan, Pierre-Antoine Comby +2
Aug 4, 2026cs.CV

Towards Reliable and Reproducible Fetal Brain Biometry: A Deep Learning Approach Using MRI

Fetal brain biometry is essential for quantitative assessment of brain development, supporting gestational age estimation, developmental monitoring, and detection of abnormalities. In clinical practice, measurements are manually performed, making them time-consuming and prone to variability. While automated approaches have been proposed, reproducible methods remain limited, particularly those providing anatomically interpretable landmark localization. We present a fully automated deep learning-based framework for reliable and reproducible brain biometry from 3D super-resolution-reconstructed fetal brain MRI. The proposed four-step pipeline derives biometric parameters by jointly estimating linear measurements and their corresponding anatomical landmarks. A 3D convolutional neural network is trained to regress landmark coordinates from brain segmentation label maps, followed by measurement-specific geometric optimization to refine landmark positions and compute measurements. The pipeline is evaluated on two publicly available fetal MRI datasets comprising 150 volumes (gestational age range: 20-37 weeks) acquired across different scanners and protocols, assessing five key biometric measurements across varying acquisition settings and providing a comprehensive evaluation of both measurement accuracy and landmark localization using quantitative metrics and visual assessment. Compared with the only available automated pipeline, the proposed method achieves comparable or improved accuracy for most measurements. In conclusion, we introduce a straightforward pipeline for reliable biometry estimations, with efficiency, interpretability and scalability that support integration into clinical workflows.
Francesca Maccarone, Marina Di Stefano, Giorgio Longari +7