PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

Authors: Busra BulutMaik DanneckerThomas SanchezSara Neves SilvaSteven JiaJean-Baptiste LedouxLeo PomarJoanna Sichitiu+9 more

Abstract

Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.

Explore similar work

May 11, 2026cs.CV

INFANiTE: Implicit Neural representation for high-resolution Fetal brain spatio-temporal Atlas learNing from clinical Thick-slicE MRI

Spatio-temporal fetal brain atlases are important for characterizing normative neurodevelopment and identifying congenital anomalies. However, existing atlas construction pipelines necessitate days for slice-to-volume reconstruction (SVR) to generate high-resolution 3D brain volumes and several additional days for iterative volume registration, thereby rendering atlas construction from large-scale cohorts prohibitively impractical. We address these limitations with INFANiTE, an Implicit Neural Representation (INR) framework for high-resolution Fetal brain spatio-temporal Atlas learNing from clinical Thick-slicE MRI scans, bypassing both the costly SVR and the iterative non-rigid registration steps entirely, thereby substantially accelerating atlas construction. Extensive experiments demonstrate that INFANiTE outperforms existing baselines in subject consistency, reference fidelity, intrinsic quality and biological plausibility, even under challenging sparse-data settings. Additionally, INFANiTE reduces the end-to-end processing time (i.e., from raw scans to the final atlas) from days to hours compared to the traditional 3D volume-based pipeline (e.g., SyGN), facilitating large-scale population-level fetal brain analysis. Code: https://github.com/hu2274898/INFANiTE
Xiaotian Hu, Mingxuan Liu, Hongjia Yang +10
Aug 9, 2026cs.CV

Anatomically Consistent Cross-Contrast Super-Resolution of Anisotropic Brain T2w MRI

T2-weighted (T2w) brain MRI provides fluid-sensitive soft-tissue contrast that is important for neuro-oncology and radiotherapy planning. However, T2w scans are acquired with anisotropic voxels and appear blurred or stair-stepped on coronal and sagittal views, which obscures small structures and weakens any downstream 3D analysis. We propose VIPP-SR (View-Independent Patched Projection Super-Resolution), a cross-contrast guided super-resolution framework that restores the inter-plane resolution of an existing anisotropic T2w volume without an isotropic ground-truth T2w. VIPP-SR first trains a view-independent patched generator (VIP-GAN) to learn local T1c-to-T2w anatomical correspondence from high-resolution axial slices. The trained generator is then applied to axial, coronal, and sagittal views of the T1c volume to generate three orthogonal T2w estimates. Shape-preserving patching and deepest-skip removal reduce view-specific shortcuts, thereby constraining the generator to learn patch-local representations and enabling the zero-shot inter-plane transfer. Central to VIPP-SR, a projection-based optimization then enforces anatomical consistency across the three view-specific volumes, fusing them by balancing inter-plane self-consistency against per-view data fidelity. The generator is trained on BraTS-MET and evaluated on both the held-out BraTS-MET testing set and the BraTS-GLI cohort without retraining, assessing the cross-cohort generalizability. The results validate that VIPP-SR improves downstream segmentation over the real anisotropic T2w baseline, raising mean-label Dice from 0.330 to 0.465 on BraTS-MET and, zero-shot, from 0.473 to 0.563 on BraTS-GLI and ablation studies identify inter-plane self-consistency as the main source of the gain.
Mengqi Shen, Haicheng Wang, Meghna Trivedi +4
Aug 4, 2026cs.CV

Towards Reliable and Reproducible Fetal Brain Biometry: A Deep Learning Approach Using MRI

Fetal brain biometry is essential for quantitative assessment of brain development, supporting gestational age estimation, developmental monitoring, and detection of abnormalities. In clinical practice, measurements are manually performed, making them time-consuming and prone to variability. While automated approaches have been proposed, reproducible methods remain limited, particularly those providing anatomically interpretable landmark localization. We present a fully automated deep learning-based framework for reliable and reproducible brain biometry from 3D super-resolution-reconstructed fetal brain MRI. The proposed four-step pipeline derives biometric parameters by jointly estimating linear measurements and their corresponding anatomical landmarks. A 3D convolutional neural network is trained to regress landmark coordinates from brain segmentation label maps, followed by measurement-specific geometric optimization to refine landmark positions and compute measurements. The pipeline is evaluated on two publicly available fetal MRI datasets comprising 150 volumes (gestational age range: 20-37 weeks) acquired across different scanners and protocols, assessing five key biometric measurements across varying acquisition settings and providing a comprehensive evaluation of both measurement accuracy and landmark localization using quantitative metrics and visual assessment. Compared with the only available automated pipeline, the proposed method achieves comparable or improved accuracy for most measurements. In conclusion, we introduce a straightforward pipeline for reliable biometry estimations, with efficiency, interpretability and scalability that support integration into clinical workflows.
Francesca Maccarone, Marina Di Stefano, Giorgio Longari +7