cs.CVMay 12, 2026

EchoTracker2: Enhancing Myocardial Point Tracking by Modeling Local Motion

Authors: Md Abulkalam AzadVegard HolmstrømJohn NybergLasse LovstakkenHåvard DalenBjørnar GrenneAndreas Østvik

Organizations: Norwegian University of Science and Technology, Trondheim, Norway · Clinic of Cardiology, St. Olavs Hospital, Trondheim, Norway · SINTEF Digital, Trondheim, Norway

Abstract

Myocardial point tracking (MPT) has recently emerged as a promising direction for motion estimation in echocardiography, driven by advances in general-purpose point tracking methods. However, myocardial motion fundamentally differs from motion encountered in natural videos, as it arises from physiologically constrained deformation that is spatially and temporally continuous throughout the cardiac cycle. Consequently, motion trajectories typically remain locally confined despite substantial tissue deformation. Motivated by these properties, we revisit the architectural design for MPT and find that coarse initialization in commonly used two-stage coarse-to-fine architectures may be unnecessary in this domain. In this work, we propose a fine-stage-only architecture, \textbf{EchoTracker2}, which enriches pixel-precise features with local spatiotemporal context and integrates them with long-range joint temporal reasoning for robust tracking. Experimental results across in-distribution, out-of-distribution (OOD), and public synthetic datasets show that our model improves position accuracy by 6.5%6.5\% and reduces median trajectory error by 12.2%12.2\% relative to a domain-specific state-of-the-art (SOTA) model. Compared to the best general-purpose point tracking method, the improvements are 2.0%2.0\% and 5.3%5.3\%, respectively. Moreover, EchoTracker2 shows better agreement with expert-derived global longitudinal strain (GLS) and enhances test-rest reproducibility. Source code will be available at: https://github.com/riponazad/ptecho.

Explore similar work

Sep 10, 2026eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.
Thierry Judge, Nicolas Duchateau, Andreas \Ostvik +6
May 27, 2026eess.IV

Deep Learning Strain Estimation: Is Physics-Based Simulation the Solution?

Speckle tracking echocardiography (STE) is the clinical standard for myocardial strain estimation. Despite good performance on global strain (GLS), its accuracy for regional strain remains limited, even though this biomarker is highly relevant for early diagnosis and the characterization of subtle abnormalities. from clinical data. Deep learning is a promising alternative, but its development is constrained by the lack of reliable motion references. Existing solutions rely either on STE-derived labels or on simulations generated by physics-based models, but these synthetic sequences still have limited realism compared with clinical data.In this paper, we propose a novel simulation strategy that incorporates speckle decorrelation measures from real videos and uses an iterative refinement process to improve the motion realism in the simulations. We created an open-source photorealistic dataset of 1,478 videos with reference motion, which was used to train an echocardiographic motion estimation algorithm. The proposed method achieves unmatched performance on global and regional strain, notably reaching a GLS variability of 1.42% in an inter-expert setting compared to 1.78% for the clinical reference.
Thierry Judge, Nicolas Duchateau, Andreas Østvik +13
Date pendingcs.CV

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/
John Bonnici, Matthew Baugh, Aleksandra Kulbaka +3