cs.LGMay 13, 2026

Robust and Explainable Bicuspid Aortic Valve Diagnosis Using Stacked Ensembles on Echocardiography

Authors: Christos Chrysanthos NikolaidisVasileios SachpekidisNikolas MoustakidisTheofilos MoustakidisPavlos S. Efraimidis

Organizations: Department of Electrical and Computer Engineering, Democritus University of Thrace, Xanthi, 67100, Greece · Department of Cardiology, Papageorgiou Hospital, Thessaloniki, Greece · Department of Informatics, Aristotle University of Thessaloniki, Thessaloniki, Greece · Department of Bioinformatics, University of Thessaly, Larissa, Greece

Abstract

Transthoracic echocardiography (TTE) is the first-line imaging modality for diagnosing bicuspid aortic valve (BAV), yet diagnostic performance varies with operator expertise and image quality. We developed an explainable AI model that distinguishes BAV from tricuspid aortic valves (TAV) using routinely acquired parasternal long-axis (PLAX) cine loops. A multi-backbone video ensemble was trained and evaluated using a leakage-aware, stratified outer cross-validation protocol on N=90N{=}90 patient studies (48 BAV, 42 TAV). Across fixed outer splits and 10 random seeds, the calibrated stacked ensemble achieved an outer-CV F1-score of 0.9070.907 and recall of 0.8770.877. Frame-level Grad-CAM localized salient evidence to the aortic root and leaflet plane, while globally aggregated SHAP values quantified each video backbone's contribution to the stacked prediction, enabling transparent, case-level auditability. These findings indicate that PLAX-based video ensembles can support reliable BAV/TAV classification from routine echocardiographic cine loops and may facilitate earlier detection in non-specialist or resource-limited clinical settings.

Explore similar work

Jul 15, 2026cs.CV

Anatomically Faithful but Temporally Blind: Auditing Attribution for Left-Ventricular Ejection-Fraction Estimation from Echocardiography

Background and Objective: Deep video models estimate left-ventricular ejection fraction (EF) from echocardiography with near-expert accuracy, and post-hoc attribution (Chefer relevance for transformers, Grad-CAM for CNNs) is increasingly used to certify that models "look at the right place." Yet whether these explanations are faithful both spatially and temporally is unaudited. Because EF is defined by the end-systolic (ES) and end-diastolic (ED) frames, a faithful explanation must localize the left ventricle (space) and the decisive frames (time). Methods: We fine-tune two distinct EF regressors on EchoNet-Dynamic -- a self-supervised VideoMAE transformer and a Kinetics-pretrained R(2+1)D CNN -- and audit each with architecture-matched attribution along three axes: intersection-over-relevance (IoR) against LV masks, deletion AUC, and a temporal localization index on ES/ED frames, each relative to chance with per-case 95% CIs over 50 studies. A tubelet-occlusion probe separates attribution failure from model behavior. Results: Both models are anatomically faithful -- IoR 2.91x (VideoMAE) and 1.98x (R(2+1)D) above chance -- yet temporally blind: temporal localization is indistinguishable from chance (0.97--1.00) and no better than random attribution. Occlusion shows the models do not preferentially rely on ES/ED (0.90x chance), so temporal blindness reflects model behavior, not an attribution artifact. Conclusions: Spatial faithfulness does not imply temporal faithfulness. Attribution can certify anatomical grounding while masking that a model ignores the clinically decisive frames -- a caution for XAI-based validation of video diagnostic models and a call for temporally-aware training and evaluation.
Hyunkyung Han, Min Jung Kim
Jul 31, 2026cs.CV

TAVI-TEC: An AI-Based Tool for Procedural Planning of Transcatheter Aortic Valve Implantation

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R^2 = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R^2 = 0.854). The valve-size prediction model achieved 82% overall accuracy, with most misclassifications occurring between adjacent prosthesis sizes. Though further multicenter validation and extension to additional measurements and valve platforms are required, the TAVI-TEC methodology may reduce operator variability in pre-TAVI measurements and streamline the preoperative workflows of the Heart Team for decision-making.
Alessandra Zerillo, Stefano Cannata, Diego Bellavia +4
Apr 17, 2026cs.LG

A Multimodal and Explainable Machine Learning Approach to Diagnosing Multi-Class Ejection Fraction from Electrocardiograms

Left ventricular ejection fraction (LVEF) assessment depends on echocardiography, limiting access in primary care and resource-constrained settings. We developed a multimodal machine-learning framework that combines engineered 12-lead ECG timeseries features with structured EHR variables to classify LVEF into four clinically used strata: normal (>50%), mildly reduced (40-50%), moderately reduced (30-40%), and severely reduced (<30%). To support model explainability, we identified the most influential ECG and EHR features via SHAP attributions. Using retrospective data from Hartford HealthCare, we trained XGBoost models on 36,784 ECG-echocardiogram pairs from 30,952 outpatients and evaluated temporal generalizability on 19,966 ECGs from a subsequent period. The multimodal model achieved one-vs-rest AUROCs of 0.95 (severe), 0.92 (moderate), 0.82 (mild), and 0.91 (normal), outperforming ECG-only and EHR-only baselines, and maintained performance under temporal validation. This work supports ECG-based, multimodal LVEF stratification as a practical screening and triage aid to prioritize confirmatory imaging where resources are limited.
Catherine Ning, Yu Ma, Cindy Beini Wang +4