cs.CVJul 29, 2026

Anatomy Contextualized Adaption of CT Foundation Models

Authors: Roshan KeniaStephanie L McNamaraWilliam Lotter

Organizations: Department of Biomedical Informatics, Harvard Medical School, Boston, MA · Department of Data Science, Dana-Farber Cancer Institute, Boston, MA · Department of Radiology, Massachusetts General Hospital, Boston, MA · Department of Pathology, Brigham and Women’s Hospital, Boston, MA · Department of Pathology, Harvard Medical School, Boston, MA

Abstract

CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals. Fine-grained vision-language pre-training addresses this by aligning anatomy-level visual features with anatomy-specific text, but in doing so discards the global context that whole-volume models provide. Furthermore, existing fine-grained approaches train from scratch, making them computationally expensive. We introduce Anatomy Contextualized Adaptation (ACA), a lightweight framework that adapts frozen CT foundation model representations for anatomy-level vision-language alignment while enhancing global contextualization. ACA uses TotalSegmentator to decompose CT volumes into anatomy-level embeddings, which are refined via a transformer that captures cross-anatomy relationships, and aligned to both per-anatomy and scan-level text extracted from radiology reports. Evaluated on Merlin and CT-RATE, ACA consistently outperforms both the frozen foundation model baselines and existing fine-grained methods in zero-shot finding classification, while requiring less than one hour of training once embeddings are cached. The attention weights learned by ACA's inter-anatomy transformer additionally indicate plausible cross-anatomy context routing. Altogether, these results support ACA as a lightweight approach for adapting CT foundation models to anatomically grounded vision-language alignment while preserving and enhancing global anatomical context.

Explore similar work

Jul 15, 2026cs.CV

Fine-Grained Vision-Language Pretraining with Organ-Conditioned Pattern Tokens for CT Understanding

Computed tomography (CT) vision-language pretraining from paired volumes and radiology reports is a scalable yet challenging task. Existing methods commonly adopt global scan-report contrast, which is scalable but obscures heterogeneous organ evidence. Meanwhile, direct organ-level alignment remains coarse, since the same anatomy can exhibit multiple distinct radiological appearances. Therefore, pretraining requires a finer alignment unit: the organ-conditioned radiological pattern. In this work, we propose OCP-CT, an organ-conditioned pattern-token alignment framework for CT vision-language pretraining. Specifically, OCP-CT preserves a stable global CT-report contrastive branch and introduces an organ pattern interface: sparse Mixture-of-Experts (MoE) routes image and text tokens according to latent radiological patterns, learnable slots query the routed tokens into continuous pattern tokens, and paired token contrast aligns image-text pattern tokens with structured soft targets built from report-derived clinical similarity. On the publicly available CT-RATE and RAD-ChestCT benchmarks, OCP-CT achieves average AUROCs of 84.5% and 69.9% for zero-shot abnormality diagnosis, respectively. Compared with the strongest prior reported results, these results yield absolute AUROC gains of 6.7 and 0.8 percentage points.
Guoliang You, Xiaomeng Chu
Jun 7, 2026cs.CV

CheXanatomy: Anatomy-Aware Vision-Language Modeling for Chest Radiographs

Vision-language models (VLMs) pretrained on large-scale image-text pairs demonstrate strong image-level understanding, but are primarily optimized for global alignment and do not explicitly encode fine-grained anatomical structure, limiting their suitability for spatially precise tasks such as segmentation. We introduce CheXanatomy, a framework that integrates explicit anatomical knowledge into a pretrained VLM through autoregressive token-space supervision. Instead of adding task-specific decoder heads, the model is trained to generate anatomical segmentation masks via next-token prediction. To enable scalable supervision, we synthesize realistic chest radiographs from CT volumes and forward-project CT segmentation labels to obtain anatomically consistent 2D masks. We evaluate the approach on synthetic and real chest radiographs against a U-Net baseline, including ablations on model scale, input resolution, and vision encoder fine-tuning. Autoregressive anatomical supervision achieves performance comparable to specialized convolutional models in-distribution and demonstrates improved geometric robustness under domain shift to real CXR data. In addition, anatomy-pretrained models exhibit improved sample efficiency when adapting to novel localization tasks under limited supervision. Larger models and higher input image resolution improve performance, while vision encoder fine-tuning has limited effect. These results show that embedding anatomical structure directly into the generative objective promotes spatially grounded representations and supports anatomy-aware medical vision-language modeling.
Sergios Gatidis, Curtis Langlotz, Christian Bluethgen
Jan 1, 2026cs.CV

TotalFM: An Organ-Separated 3D-CT Foundation Model Leveraging Large-Scale Routine Clinical Radiology Data

While foundation models in radiology are expected to be applied to various clinical tasks, computational cost constraints remain a major challenge when training on 3D-CT volumetric data. In this study, we propose TotalFM, a radiological foundation model that efficiently learns the correspondence between 3D-CT images and linguistic expressions based on the concept of organ separation, utilizing a large-scale dataset of 140,000 series. By automating the creation of organ volume and finding-sentence pairs through segmentation techniques and Large Language Model (LLM)-based radiology report processing, and by combining self-supervised pre-training via VideoMAE with contrastive learning using volume-text pairs, we aimed to balance computational efficiency and representation capability. In zero-shot organ-wise lesion classification tasks, the proposed model achieved higher F1 scores in 83% (5/6) of organs compared to CT-CLIP and 64% (9/14) of organs compared to Merlin. These results suggest that the proposed model exhibits high generalization performance in a clinical evaluation setting using actual radiology report sentences. Furthermore, in zero-shot finding-wise lesion classification tasks, our model achieved a higher AUROC in 83% (25/30) of finding categories compared to Merlin. We also confirmed performance comparable to existing Vision-Language Models (VLMs) in radiology report generation tasks. Our results demonstrate that the organ-separated learning framework can serve as a realistic and effective design guideline for the practical implementation of 3D-CT foundation models. The source code and pretrained models are publicly available at https://github.com/jichi-labo/TotalFM.
Kohei Yamamoto, Tomohiro Kikuchi