Abstract
Anomaly detection in Industrial Internet of Things (IIoT) environments is essential to protect the Industrial Control Systems (ICS) and Cyber-Physical Systems (CPS) from occuring run time false data injection and other malicious attacks. The increasing complexity of sensor networks and interconnected control loops makes it difficult to identify anomalous behavior hidden within high-dimensional and time-dependent signals. To address these challenges, this article introduces Adaptive Spatio-Temporal Reinforcement Optimization ASTRO (ASTRO), a novel anomaly detection framework that pioneers the use of reinforcement learning for dynamic threshold optimization. By integrating a Deep Q-Network (DQN) with Graph Neural Networks (GNNs), temporal modelling and a Multi-Head Attention mechanism, ASTRO continuously adapts its decision boundaries to improve detection accuracy. The GNN component models the spatial relations among sensors, Temporal model captures time series dependencies and the attention layer highlights most informative time steps. The model generates continuous anomaly scores, which are transformed into binary decisions using an adaptive threshold, optimized via a Deep Q-Network (DQN). The ASTRO approach is evaluated on two real world industrial benchmarks: the Secure Water Treatment (SWaT) and Water Distribution (WADI) datasets. The proposed model achieves an exceptional performance on the SWaT with F1 score of 0.990. Moreover, on highly complex 127 end devices WADI dataset, it secures F1 score of 0.788, outperforming state-of-the-art baselines by nearly 14%. Results across multiple runs confirm consistent generalization and stability. These experiments demonstrate that the ASTRO framework is highly practical and scalable method for strengthening the large scale cyber physical infrastructures
Explore similar work
Jun 1, 2026cs.CR
Industrial Internet systems face increasing threats from sophisticated industrial control system (ICS) attacks, resulting in critical safety incidents. However, existing tools exhibit limited effectiveness in real-time anomaly detection due to the complex dependencies among sensors and actuators. To tackle this, we present IstGPT, the first industrial anomaly detection tool based on LLMs and graph learning to provide real-time protection against a wide range of ICS attacks. IstGPT achieves fine-grained and precise modeling on spatial-temporal dependencies in industrial cyber-physical systems. It first leverages industrial multi-modal knowledge, including operational data, technical documents, and system diagrams, to extract sensor-actuator dependency graphs via multi-stage prompt engineering. Then, LLM-Optimation iteratively refines the graph based on node accuracy, edge consistency, and logical coherence. Finally, IstGPT integrated improved graph neural networks with an encoder-decoder architecture to detect anomalies via reconstruction errors. We evaluate IstGPT against 12 state-of-the-art baselines on 9 datasets, including 2 public, 6 simulated, and a real-world robotic arm dataset. IstGPT achieves the best F1-scores and eTaF1 (a newer time-aware metric) across nine datasets. We further discuss the feasibility of deploying IstGPT in real-world industrial scenarios.
Yuchen Zhang, Ning Xi, Pengbin Feng +5
Sep 7, 2026cs.CR
Anomaly-based intrusion detection systems in industrial control systems (ICS) and operational technology (OT) environments are increasingly required to meet formal resilience criteria: absorbed adversarial disturbances, graceful degradation under sustained attack, and certified system-level guarantees. Existing resilience frameworks for cyber-physical systems define absorb-recover-adapt trajectories at the architectural level but do not treat machine learning anomaly detectors as first-class components, leaving a gap between component-level robustness evaluation and system-level resilience certification. In this paper, we establish that adversarial robustness in ICS anomaly detection is a specific instantiation of system resilience, and formalise this connection by mapping four resilience constructs, i.e. disturbance class, absorption capacity, recovery trajectory, and degradation function, onto the adversarial machine learning setting. We derive a compositional resilience bound for heterogeneous ICS detection networks, showing that the binding constraint on system-level resilience is the coupling-adjusted absorption capacity of each node along the attack path, not the per-node capacity -- so the binding node need not be the weakest one. Empirical validation on the BATADAL water distribution system benchmark demonstrates that the resulting metrics surface operationally significant phenomena invisible to standard benchmarks: the absorption-degradation divergence under adversarial training, and the paradox that hardening the binding node in isolation reduces system-level resilience. Implications for ICS architecture design and certification standards are discussed.
Branka Stojanović, Andreas Flatscher, Michael Somma
Jul 25, 2026cs.LG
Anomaly detection on multivariate sensor time series is critical for industrial monitoring of cyber-physical systems (CPS), where even subtle deviations from normal behavior can indicate process disruption. Recent graph-based approaches have made significant progress, but they often struggle in small-scale physical systems with scarce labeled anomalies and limited normal data. In such settings, graph-based models tend to capture spurious correlations and produce unstable sensor topologies. We propose DPR-GM (Domain-Prior-Regularized Graph Modeling), a forecasting-based framework that incorporates system design knowledge into graph construction. DPR-GM leverages a large language model (LLM) to extract directed physical couplings between sensor pairs from system documentation, which are encoded as a binary domain adjacency matrix serving as a structural gate over sensor relations. This gate is then modulated by Pearson correlations estimated from normal training data. The anomaly score is further weighted by sensor-level reliability derived from the coefficient of variation. All graph and weighting components are fixed prior to training and add no learnable parameters. On the SKAB benchmark, DPR-GM outperforms graph-based, statistical, and deep learning baselines across F1, AUROC, and AUPRC, showing that domain-structured graph priors are a practical alternative to fully learned topologies in data-scarce CPS.
Youngseok Hwang, Joonsung Kwon, Geonwoo Lee +1