cs.HCMay 25, 2026

Posture Clip: Sit properly or I wont let you work

Authors: Arka MajhiAparajita Mondal

Organizations: Faculty of Information Technology and Communication Sciences, Tampere University, Tampere, 33100, Pirkanmaa, Finland. · School of Forest Sciences, University of Eastern Finland, Joensuu, 80101, North Karelia, Finland.

Abstract

Poor posture is a significant concern due to its detrimental effects on health and productivity. This paper presents a collar-clipped device called PostureClip, designed to restrict users from sitting and working at a bent angle, by blacking out the screen and resuming on correcting posture, thereby promoting better posture. The device integrates sensors and feedback mechanisms to provide real-time posture feedback to users. To evaluate the effectiveness of PostureClip, a controlled experiment was conducted with participants (n=165) who were working on a laptop/PC for over 6 hours per day. The participants were randomly assigned to both the intervention group (IG1,n=54 ; IG2,n=55), which used the collar-clipped device, and the control group (CG, n=56), which did not use the device. IG1 didn't get feedback while IG2 got feedback from the device by notifying and further darkening the screen. The study was conducted in the office environment of the participants, for 4 weeks, and metrics such as posture angle, duration of bent angle, and user feedback were collected. Analysis revealed significant improvements in posture angle (p<0.001) and significant reduction in bent angle duration (p<0.01) for participants' group using PostureClip with feedback and compared to the group without feedback and the control group (who were not intervened). The qualitative analysis of user feedback highlighted the device's ease of use, effectiveness in providing timely feedback, and positive impact on participants' awareness and habits regarding posture. These results indicate that PostureClip is an effective tool for promoting better posture during sedentary work.

Explore similar work

Jun 1, 2026cs.RO

Impact of a Soft Wearable Back-Support Device on Postural Stability during Trip-Like Perturbations

The effectiveness of a soft wearable back-support device in enhancing postural stability was investigated under trip-like perturbations using two experimental paradigms: perturbed standing and perturbed walking. Healthy subjects completed trials under three different back-support conditions: no device, device worn with low stiffness, and device activated with high stiffness. Whole-body stability was quantified using the minimum Margin of Stability (MOS) at the point of maximal instability. Results demonstrated increased MOS during device use, indicating enhanced postural stability. In standing, MOS increased significantly with device stiffness, whereas in walking, both device conditions improved MOS relative to no device but did not differ significantly from each other. These findings highlight the potential of soft wearable back-support devices with adjustable stiffness to improve reactive balance control against external perturbations, with important implications for fall prevention. Future research should explore personalized stiffness optimization and evaluate efficacy in populations at elevated risk of falls.
Yuanhao Chen, Rohan Khatavkar, Soubhagya Nayak +2
Jun 1, 2026cs.RO

Improved Postural Stability Using a Lightweight Semi-Active Soft Back Support Device Under Standing Perturbations

Older adults are particularly susceptible to falls following perturbations during standing, such as forward loss of balance. Back support devices that assist trunk extension may help mitigate fall risk by preventing excessive trunk flexion. Previous studies have investigated heavy back support devices; however, these systems often introduced adverse effects on stability due to their added mass, which shifted the body's natural center of mass unfavorably. In contrast, lightweight passive devices have shown limited benefits, as they can generate only modest assistive forces during the relatively small trunk flexion associated with forward balance loss. In this study, we evaluated the effects of a lightweight semi-active soft back support device on postural stability following standing perturbations. Our device combines an active element (a pneumatic artificial muscle) in parallel with a passive elastic band. The active element rapidly provides assistive force following a perturbation, overcoming the limitations of passive devices. Experiments conducted with five healthy individuals demonstrated that the semi-active device significantly reduced whole-body angular momentum and increased the margin of stability, indicating improved balance recovery performance. These results highlight the promise of semi-active soft wearable robots as an effective and lightweight strategy for fall prevention during standing perturbations.
Rohan Khatavkar, Jiefeng Sun, Hyunglae Lee
Aug 3, 2026cs.LG

Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model

Accurate detection of sedentary behavior is important for studying health risks related to prolonged sitting, but posture-based classification remains challenging with wearable sensors, especially at the wrist. We study whether a deep learning model trained on hip-worn accelerometer data can transfer to wrist-worn accelerometer data for sitting versus non-sitting classification. We use CHAP, a CNN-BiLSTM model originally developed for hip accelerometers, and evaluate its zero-shot performance on wrist data as well as its adaptation through finetuning with varying amounts of labeled wrist data. Experiments are conducted on the iWatch dataset with ground-truth posture labels derived from wearable cameras. The hip-trained model performs strongly on hip data without retraining, but accuracy drops on wrist data due to sensor placement shift. Finetuning CHAP provides consistent advantages over transformer models trained from scratch. These findings suggest that hip-based pretraining provides a useful starting point for wrist deployment, while highlighting the need for wrist-specific adaptation to handle higher signal variability.
Yuliang Chen, Weiwei Shi, Jingjing Zou +10