cs.CVMay 25, 2026

Broadband Hyperspectral 3D Imaging using Dispersed Structured Light

Authors: Suhyun ShinYunseong MoonRyota MaedaDavid B. LindellKiriakos N. KutulakosSeung-Hwan Baek

Abstract

Hyperspectral 3D imaging enables the capture of dense spectral information and scene geometry but has traditionally been confined to narrow spectral windows, typically the visible range. In this work, we introduce a broadband hyperspectral 3D imaging (BH3D) method to extend this capability across the full visible-near-infrared and short-wavelength infrared (SWIR) spectrum (450-1500 nm). This broad coverage is critical as it captures complementary physical cues: visible wavelengths reveal surface appearance, while SWIR bands provide insight into subsurface properties and material composition. However, realizing BH3D is challenging due to fundamental sensor constraints between visible-spectrum silicon and SWIR-spectrum InGaAs sensors, which necessitate complex multi-spectrograph designs. Here we propose a single-spectrograph BH3D system, using a stereo setup comprising visible and SWIR cameras, that reconstructs dense broadband hyperspectral reflectance together with accurate 3D geometry. Our key idea is to extend dispersed structured light to the broadband regime using a single spectrograph. We model the image formation of broadband dispersed structured light, and estimate hyperspectral reflectance and depth. We validate our approach on diverse real-world scenes, demonstrating accurate reconstruction with a mean spectral angle mapper of 0.13 rad, root mean square error of 0.03, and mean depth error of 4.5 mm. We further demonstrate identifying metameric materials, performing imaging through opaque layers, uncovering hidden features on banknotes, and revealing blood vessels.

Explore similar work

Apr 22, 2026eess.IV

Broadband Wide Field of View Imaging with Computational Mirrors

Traditional glass-based optics are typically optimized for narrow spectral bands, such as the visible (400-700nm) or shortwave infrared (1000-1800nm). While the emergence of VIS-SWIR sensors (400-1700nm) offers transformative potential, refractive optics struggle to focus this entire range simultaneously. Mirrors represent a promising achromatic alternative; however, they are often sidelined by field curvature, and off-axis aberrations. This paper introduces Computational Mirrors, a framework that enables high-resolution, wide-field-of-view imaging across the complete VIS-SWIR spectrum using a single sensor. Our method is built on the observation that distinct regions of the field of view reach focus at varying distances from the mirror. By capturing a minimal focal stack (2-4 images), we utilize a computational backend to recover a sharp, all-in-focus image. A key contribution of this work is SeidelConv, a novel, physics-inspired, spatially-varying point spread function (PSF) model designed to accurately characterize and correct the off-axis aberrations inherent in simple concave mirrors. We demonstrate the efficacy of our approach using a first-of-its-kind 50mm F/1 optical system equipped with a VIS-SWIR sensor. Our system produces sharp images across RGB, NIR, and SWIR wavelengths without requiring refocusing, revealing material details invisible within individual spectral bands. We further validate the scalability of our approach with a 100mm F/2 system optimized for long-range imaging.
Vishwanath Saragadam, Niki Nezakati, Amit Roy-Chowdhury +1
Sep 20, 2026cs.CV

Compact Low-Cost Hyperspectral Imaging via Angular-to-Spectral Diversity Conversion

Snapshot hyperspectral imaging avoids sequential scanning, but systems that jointly achieve stable reconstruction, low cost, and compact optics remain limited. We present a snapshot hyperspectral imaging system based on angular-to-spectral diversity conversion. A tapered kaleidoscope creates replicated views with distinct incidence directions, and a directly attached birefringent filter converts them into view-channel-dependent spectral transmittances, yielding complementary measurements that better condition the inverse problem for more stable single-shot spectral reconstruction. The system preserves a simple pixel-wise linear model for fast non-learning-based reconstruction and uses only off-the-shelf components without relay optics or cascaded modules. We select the birefringent filter configuration using a condition-number-based criterion and validate the system on both synthetic and real data.
Kazuma Fujiwara, Takuya Funatomi, Kazuya Kitano +2
Jun 12, 2026cs.CV

A Lightweight Fiducial-Based Pipeline for 3D Hyperspectral Mapping of ex-vivo Lumpectomy Specimens

Hyperspectral Imaging (HSI) is a promising modality for intraoperative assessment of resection margins in Breast-Conserving Surgery (BCS), but its clinical translation requires aligning the inherently 2D spectral information onto the 3D shape of the excised tissue so that suspicious regions can be precisely localized for targeted follow-up. We present a fully automated, calibration-free pipeline that produces a 3D hyperspectral point cloud of an ex-vivo lumpectomy specimen from a set of consumer-camera RGB images and a single top-down HSI acquisition. The 3D geometry is reconstructed with a deep-learning Structure-from-Motion backbone, stabilized in a metric reference frame by a custom bundle adjustment that enforces consistency on the corners of four ArUco markers placed around the specimen. The HSI cube is then registered to the reconstruction without recovering the HSI camera pose: the markers, visible in both modalities, define 16 corner correspondences that drive a planar homography, and 3D coordinates are recovered by lookup on an orthographically rendered depth map. Evaluated on two ex-vivo lumpectomy specimens, the pipeline achieves a median 3D registration error below 1~mm and a 2D reprojection error below 0.02 mm, with a total per-specimen processing time under 4 minutes on accelerated hardware. These results support the feasibility of integrating HSI-guided spatial localization into intraoperative margin assessment workflows for breast-conserving surgery.
Anna Bicchi, Alberto Rota, Leonardo Passoni +5