Application of Algorithms in Energy-Efficient Design Platforms for Green Building
Authors: Na Yu, Fu Wenli, Guo Fei
Organizations: First Highway Engineering Co., Ltd. Chengdu, Sichuan Province, 610000, China
Abstract
During green building design, computer-aided energy assessment is widely used to improve efficiency and achieve overall optimization. This paper presents a platform that combines Building Information Modeling (BIM), sensor operational data, and advanced simulation workflows using robust algorithms. The platform uses a multi-layer service architecture with dynamic energy simulation and evolutionary multi-objective optimization, connected via a high-performance C++ core and adaptive agent models. A mid-rise office building was selected as the case study. Five representative areas were chosen to collect data on building envelope characteristics and occupancy patterns. After preprocessing, missing sensor data accounted for 3.2% of annual records, and all variables were standardized using 15-minute interpolation. After 40 optimization rounds, annual energy consumption per square meter dropped by 29.3% from 315 kWh/m2 to 223 kWh/m2. The lifecycle cost increase for occupants was limited to 3.7%, and discomfort hours were reduced to under 70 hours per year. Analysis of Pareto optimal solutions shows that the envelope U-value ranges from 1.05 to 1.57 W/m2K, and nighttime ventilation rate ranges from 2.1 to 3.6 h-1, both closely linked to energy performance. The results confirm that the integrated algorithm framework offers good scalability, strong performance, and technical feasibility for green building design. This platform provides a reliable decision-support tool for design engineers and sustainability practitioners, enabling accurate, data-driven delivery of energy-efficient buildings.
This study proposes a scalable Digital Twin framework for energy optimization in data centers.The framework integrates IoT-based data acquisition, cloud computing, and machine learning techniques to enable real-time monitoring, forecasting, and intelligent energy management. A controlled small-scale data center environment was developed to monitor variables such as power consumption, temperature, and computational workload. Long Short-Term Memory (LSTM) models were employed to predict energy demand and support operational decision-making. Experimental results demonstrated improvements in energy efficiency, including reductions in power consumption and enhancements in Power Usage Effectiveness (PUE). Despite being evaluated in a constrained environment, the proposed framework demonstrates strong potential as a scalable and cost-effective solution for sustainable data center management.
Raphael Hendrigo de Souza Gonçalves, Wendel Marcos dos Santos
Accurate estimation of building energy use is essential for achieving carbon neutral and sustainable buildings. To better understand the influence of design decisions on building energy use and calibrate machine learning models that can give architects and engineers rapid design feedback, large-scale datasets are needed that explicitly map building geometry to performance. We present ArchEGraph, a large-scale benchmark dataset that represents buildings as heterogeneous graphs with aligned geometry, topology, weather, and zone-level thermal loads. The dataset contains 5,481 buildings and 49,326 validated building-weather simulation cases. In total, it includes over 133,000 space nodes and 1.44 million face nodes, reflecting substantial geometric and topological complexity. Based on ArchEGraph, we define two benchmark tasks: (i) graph reconstruction from polygonal meshes, aiming to recover topological structure from geometric representations; and (ii) topology-informed load prediction, which leverages graph structure and temporal weather conditions to forecast zone-level response time series. We further introduce standardized evaluation protocols for both tasks and conduct cross-building and cross-climate generalization experiments to assess model robustness. ArchEGraph provides a unified testbed for studying geometry-topology-physics coupling in building energy modeling, enabling the development and evaluation of scalable and generalizable surrogate models.
As Green Software Engineering matures, energy efficiency has transitioned into a mission-critical non-functional requirement. While software design patterns ensure structural integrity, their inherent abstraction layers impose an implicit "metabolic cost" that often remains obscured during the design phase. This paper empirically investigates the energy dynamics of the Memento design pattern, contrasting a direct, unabstracted baseline against Classic full-snapshot and Differential delta-encoding strategies. Leveraging the RAPL interface for high-fidelity hardware telemetry, we quantify energy dissipation across state volumes scaling from 10 MB to 200 MB. Our empirical results expose a critical architectural trade-off: the Differential strategy minimizes memory traffic, yielding a maximum energy reduction of 65.8% for mid-scale states, but collides with a catastrophic "memory wall" at 200 MB. At this saturation point, algorithmic optimizations are completely neutralized by severe GC thrashing and non-linear power spikes. We synthesize these findings into evidence-based heuristics, providing architects with a robust framework to reconcile structural design quality with sustainable Green IT imperatives.