Organizations: National University of Singapore · University College Dublin · University of Twente · Cardiff University
Abstract
Epilepsy is one of the most common neurological disorders globally, characterized by recurring seizures and significantly impacting the quality of life. Despite advancements in diagnostic techniques, the mitigation of risks faced by epilepsy patients remains challenging due to the unpredictability of seizure events. An accurate forecast of seizure onset helps to reduce risks in epilepsy patients. In this paper, we propose EEG-FuseFormer, a transformer-based feature fusion framework for seizure-onset prediction that combines intermediate features extracted from Convolutional Neural Networks-Long Short-Term Memory (CNN-LSTM) and ResNet-18 networks. The CNN-LSTM architecture captures both spatial and temporal features directly from the raw signal, whereas the ResNet-18 extracts features from the Short-Time Fourier Transform (STFT) representation of the EEG signals. Fusion is carried out using a transformer encoder, and the final prediction is generated using fully connected dense layers. The CHB-MIT dataset was used to validate the proposed model. The results show that the proposed model achieves a mean recall of 98.85% and outperforms most of the state-of-the-art methods. This study evaluates the ability of the proposed feature fusion model to generalize in cross-patient testing scenarios. Fine-tuning pre-trained models on limited target patient data (target adaptation) within the cross-patient validation framework results in higher recall, precision, and F1-score metrics in comparison to the conventional cross-patient validation approach. Finally, the runtime-based computational complexity of the model is assessed across diverse hardware platforms to highlight the performance-complexity trade-off.
Electroencephalography (EEG) models used for epilepsy are often limited to specific datasets and tasks. This limited approach can make it challenging to apply these models across different datasets or in various situations. However, recent studies in foundation models and self-supervised learning suggest that an adaptable EEG backbone could support a range of EEG related tasks. In this study, we have developed a multimodal EEG foundation model that combines a raw signal encoder based on the Mamba architecture, a Vision Transformer (ViT)-style encoder for time-frequency data, and a lightweight encoder for text, all within a shared embedding space. The pretraining process relies on several innovative techniques, such as masked modeling, cross-view contrastive alignment, and temporal consistency losses. These methods are designed to create rich, seizure-relevant representations without requiring labeled data. To assess the efficacy and generalization of our pretrained model, we fine-tuned it on the canonical CHB-MIT seizure detection benchmark and additional seizure detection datasets, and conducted extensive experiments comparing different model variants. On the standard CHB-MIT split, our best single model achieved an AUROC of 0.874, and an ensemble variant reached 0.878 AUROC, representing state-of-the-art performance on this benchmark. In addition to standard train-test splits, we evaluated performance under a leave-one-subject-out (LOSO) protocol, which is rarely reported in prior EEG seizure modeling work and highlights the difficulty of patient-independent seizure detection, with a mean LOSO balanced accuracy of 0.558 across 19 subjects. Across datasets and evaluation settings, our multimodal foundation model enabled robust seizure detection and straightforward adaptation to new seizure detection scenarios, while also supporting interpretable seizure localization.
Deep learning for EEG-based seizure detection faces critical challenges: severe annotation scarcity and extreme class imbalance, where ictal events comprise less than 10% of clinical recordings. We present DiffEEG, a 9.6M-parameter self-supervised foundation model that addresses both limitations through denoising diffusion pre-training and reinforcement learning (RL)-based fine-tuning. Pre-trained on 1.3M unlabeled segments from the Temple University Hospital Seizure Corpus (TUHSZ), DiffEEG learns generic neural representations via a 1D U-Net with multi-head self-attention. For downstream adaptation, a reinforced decision layer employs policy gradient optimization to directly maximize F1-score, prioritizing sensitivity to rare seizure events over overall accuracy. Under strict patient-wise evaluation (279 patients, Leave-One-Fold-Out), DiffEEG achieves 61% accuracy and 59% F1 for 4-class seizure subtyping, and 81% accuracy with 85% weighted F1 for binary detection, maintaining clinically viable seizure recall (59%) despite extreme imbalance (6.7% prevalence). Segment-level evaluation establishes an upper bound of 97.6% accuracy, confirming strong architectural capacity. DiffEEG demonstrates that diffusion-based pre-training combined with metric-aware reinforcement learning enables clinically deployable seizure monitoring with minimal labeled data requirements.
Abdulkader Helwan, Lina Abou-Abbas, Hussein El Amouri +2
Reliable seizure prediction is a prerequisite for closed-loop neurostimulation therapy, yet existing methods rarely account for the variability in EEG signal quality encountered in real-world deployment, and the overwhelming majority adopt non-strict evaluation protocols that overestimate generalisation performance. We propose CLSP-REQA (Closed-Loop Seizure Prediction with Real-time EEG Quality Assessment), a unified framework that embeds a lightweight signal quality estimator directly within the prediction pipeline. A Real-time EEG Quality Assessment (REQA) module runs in parallel with a Mamba-BiLSTM backbone, producing a scalar quality score q in [0,1] that modulates output confidence through a tiered non-linear fusion function (ECLO). Under strict cross-patient evaluation on the CHB-MIT Scalp EEG Database (n = 23 subjects, 198 seizures), CLSP-REQA achieves an AUC-ROC of 0.7426 +- 0.0199, outperforming the unadapted cross-patient baseline of 0.69 reported by Jemal et al., using only 16 EEG channels compared to 23 in prior work, and without requiring any target-patient data or domain adaptation. On the SIENA Scalp EEG Database (n = 14 subjects, 47 seizures), CLSP-REQA achieves AUC 0.7012 +- 0.0249, substantially surpassing the best domain-adapted cross-patient result of 0.61 on the same dataset, demonstrating strong cross-dataset generalisation. The framework outputs a structured four-tuple (p, q, c, Phi_SHAP) directly compatible with closed-loop neurostimulator interfaces.