eess.IVJun 8, 2026

Deep Slice Interpolation for Reducing Through-Plane Anisotropy and Noise in Head CT

Authors: Luis Cortés FerreMiguel A. Gutiérrez-NaranjoMarcin Balcerzyk

Abstract

Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels. We present a deep learning system that synthesizes intermediate CT slices from pairs of neighboring axial slices, halving the effective through-plane spacing. The system improves three-dimensional visualization while simultaneously producing inherently denoised outputs, yielding two complementary benefits from a single inference pass. To build a reliable system, we systematically evaluate pixel-wise losses, namely mean squared error (MSE) and mean absolute error (L1); structural-similarity losses, namely the structural similarity index (SSIM) and its multi-scale variant (MS-SSIM); and hybrid combinations. On a held-out test set, all converged models outperform classical interpolation baselines and pretrained video frame interpolation methods (RIFE, FILM) on all structural measures, with MS-SSIM+L1 offering the strongest balanced profile. We also document training instability in SSIM-family losses and identify partial remedies: the standard numerical fixes eliminate the dominant failure mode but leave residual divergence at smaller batch sizes. All results are reported with patient-level bootstrap confidence intervals and paired statistical tests. As an illustration, we apply the system to an out-of-distribution head CT series from Hospital Universitario Virgen del Rocío: the model synthesizes intermediate slices and exhibits on the real slices the implicit-denoising signature predicted by our theoretical analysis, supporting in a single external case that interpolation quality and implicit denoising are not confined to the training distribution.

Explore similar work

May 15, 2026eess.IV

Deep Learning for MRI Slice Interpolation: The Critical Role of Problem Formulation

Through-plane resolution in clinical MRI is typically much coarser than in-plane resolution, limiting diagnostic utility. This work investigates deep learning approaches to interpolate intermediate MRI slices in prostate imaging, effectively doubling through-plane resolution. I evaluated five architectures (CNN, U-Net, two GAN variants, and DDPM) and discovered that problem formulation has dramatically more impact than architectural complexity. By reformulating the interpolation task to use adjacent slices (i-1, i+1) rather than distant slices (i-2, i+2), I achieved a 58% improvement in SSIM performance across all deterministic architectures. The U-Net model achieved the best results with PSNR of 30.08 dB and SSIM of 0.898, representing a 10.1% improvement over linear interpolation baseline. A DDPM was also evaluated but showed poor reconstruction quality due to fundamental mismatch between stochastic generation and deterministic reconstruction requirements. These findings demonstrate that problem formulation can have 290x more impact than architectural sophistication in medical imaging tasks.
Shamit Savant
Jun 14, 2026cs.CV

CRIS: Cross-Plane Self-Supervised Isotropic Restoration for Anisotropic Volumetric Imaging Across Modalities

Anisotropic volumetric acquisitions are common in clinical MRI and volume electron microscopy (vEM), where sparse through-plane sampling creates thick slices or sections that degrade orthogonal reformats and downstream analysis. We present CRIS, a cross-plane self-supervised framework for isotropic restoration without paired isotropic ground truth. CRIS casts 3D restoration as 2D stripe completion on orthogonal reformats of an isotropic grid: high-resolution in-plane slices are synthetically degraded and periodically masked for training, while at inference blank slices define the isotropic grid, two orthogonal reformats are restored, and predictions are fused by multi-view averaging. We evaluate CRIS on two MRI cohorts and two microscopy benchmarks up to 8x anisotropy. On brain MRI, CRIS achieves 32.921 +/- 0.436 dB PSNR and 0.963 +/- 0.003 SSIM, outperforming interpolation, ECLARE, SMORE4, SIMPLE, SA-INR, and ATME, and gives the best segmentation consistency (Dice 0.940 +/- 0.004, ASSD 0.245 +/- 0.014 mm, HD99 1.275 +/- 0.061 mm). On reference-free abdominal MRI, CRIS reduces FID/KID to 48.71/0.023, outperforming interpolation, ECLARE, SMORE4, and SIMPLE. On vEM, CRIS achieves 29.100 dB/0.830 3D PSNR/SSIM at 4x and 26.874 dB/0.722 at 8x on EPFL, and 21.935 +/- 0.437 dB/0.696 +/- 0.024 on noisy hemibrain data. In a dedicated robustness experiment, one variable-gap CRIS model evaluated across gap factors 3-7 and coronal, axial, and sagittal degradations maintained higher PSNR/SSIM than interpolation (36.36-31.14 dB and 0.977-0.932 vs. 33.07-27.85 dB and 0.951-0.853). These results support CRIS as a modality-flexible route to isotropic restoration without paired isotropic targets or configuration-specific retraining. Code is available at https://github.com/adi-hatav/CRIS.
Adi Ahituv, Anat Ilivitzki, Moti Freiman
Jun 25, 2026eess.IV

Dual-Prior Guided Null-Space Learning with Mixture-of-Splines for Arbitrary Medical Slice Super-Resolution

Arbitrary slice super-resolution reconstructs isotropic volumes from anisotropic clinical acquisitions by synthesizing intermediate slices at arbitrary scales. However, treating this ill-posed inverse problem as unconstrained residual-based regression risks hallucinating anatomically implausible structures or altering the originally observed data. To address both concerns, this paper presents the Dual-Prior Null-space Learning (DP-NSL) framework, which reformulates the task as a constrained recovery process guided by two complementary priors. A Measurement-Consistent Projection (MCP) enforces a Deterministic Observation Prior: the reconstruction undergoes an exact orthogonal projection that reproduces every acquired slice with zero error, confining all learned details to the unobservable null space. Within this null space, a Mixture-of-Splines (MoS) module imposes a Geometric Continuity Prior by dynamically mixing B-spline experts of different analytic orders, allowing each anatomical region to be modeled with a content-aware level of continuity. To promote spatial coherence, a Local Spatial Consistency Decoder (LSCD) further injects local inductive bias. Experiments on three CT and one MRI benchmark show that DP-NSL outperforms existing approaches while strictly preserving measurement consistency. Code is available at https://github.com/DeepMed-Lab-ECNU/Medical-Image-Reconstruction.
Haofei Song, Siyuan Xu, Xintian Mao +3