Dual-Prior Guided Null-Space Learning with Mixture-of-Splines for Arbitrary Medical Slice Super-Resolution
Authors: Haofei Song, Siyuan Xu, Xintian Mao, Shaojie Guo, Qingli Li, Yan Wang
Organizations: Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University, Shanghai 200241, China
Abstract
Arbitrary slice super-resolution reconstructs isotropic volumes from anisotropic clinical acquisitions by synthesizing intermediate slices at arbitrary scales. However, treating this ill-posed inverse problem as unconstrained residual-based regression risks hallucinating anatomically implausible structures or altering the originally observed data. To address both concerns, this paper presents the Dual-Prior Null-space Learning (DP-NSL) framework, which reformulates the task as a constrained recovery process guided by two complementary priors. A Measurement-Consistent Projection (MCP) enforces a Deterministic Observation Prior: the reconstruction undergoes an exact orthogonal projection that reproduces every acquired slice with zero error, confining all learned details to the unobservable null space. Within this null space, a Mixture-of-Splines (MoS) module imposes a Geometric Continuity Prior by dynamically mixing B-spline experts of different analytic orders, allowing each anatomical region to be modeled with a content-aware level of continuity. To promote spatial coherence, a Local Spatial Consistency Decoder (LSCD) further injects local inductive bias. Experiments on three CT and one MRI benchmark show that DP-NSL outperforms existing approaches while strictly preserving measurement consistency. Code is available at https://github.com/DeepMed-Lab-ECNU/Medical-Image-Reconstruction.
Neighboring-slice self-supervised denoising is attractive for volumetric medical imaging, yet inter-slice misalignment breaks anatomical correspondence and often yields ghosting and blurred margins when adjacent slices are used naively as targets. We propose Neighbor-Guided Patch Sampling (NGPS), a lightweight framework that constructs neighboring supervision under local inter-slice misalignment without explicit registration. To avoid learning from misleading targets, prior methods commonly mask discrepant regions, but this stabilizes training at the cost of leaving a non-trivial portion of neighboring evidence unexploited, particularly around high-frequency anatomical boundaries. NGPS addresses this by decoupling structure matching from signal retrieval: for each masked location, it searches a local neighborhood for structurally similar candidate patches using a simple guide image (e.g., fast bilateral filtering), while retrieving the supervision signal directly from the raw noisy neighbor at the matched coordinates. By matching on a noise-attenuated guide while retrieving raw values from neighboring slices, NGPS constructs local pseudo targets without a learned registration module. Across the evaluated CT and synthetic-Rician MRI settings, NGPS improves fidelity and structure-sensitive metrics. Code is available at https://github.com/cv-cho/NGPS .
Magnetic Resonance Imaging (MRI) is often acquired with anisotropic resolution to reduce scan time, producing stair-step artifacts along the through-plane direction. In through-plane MRI super-resolution, an efficiency-fidelity trade-off arises: feed-forward regressors are fast but oversmooth at large slice-thicknesses, while sampling-based methods improve fidelity at high inference cost. We propose DRIFT, a two-stage thickness-conditioned rectified flow framework for through-plane MRI super-resolution with continuous input slice-thickness. Stage 1 employs an Anatomical Projection Network (APN) to map low-resolution patches to a coarse high-resolution manifold, providing a deterministic anatomical initialization that shortens the residual transport of Stage 2 and stabilizes slice-wise refinement. Stage 2 refines details via rectified flow and introduces a Physics-Aware Difficulty (PAD) metric derived from slice-thickness induced through-plane bandwidth deficit to guide an Adaptive Integration Scheduler (AIS), allocating ODE steps by thickness. A Consistent Endpoint Trajectory Alignment (CETA) loss enforces thickness-consistent reconstructions. Experiments show that DRIFT outperforms super-resolution baselines while reducing inference cost. Code, models, and interactive demos are available at https://yoonseokchoi-ai.github.io/drift-eccv2026/.
Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.