cs.CVJun 14, 2026

CRIS: Cross-Plane Self-Supervised Isotropic Restoration for Anisotropic Volumetric Imaging Across Modalities

Authors: Adi AhituvAnat IlivitzkiMoti Freiman

Organizations: Faculty of Data and Decision Sciences, Technion – Israel Institute of Technology, Haifa, 3200003, Israel · Rambam Health Care Campus, Haifa, 3109601, Israel · Faculty of Biomedical Engineering, Technion – Israel Institute of Technology, Haifa, 3200003, Israel · The May-Blum-Dahl MRI Research Center, Technion – Israel Institute of Technology, Haifa, 3200003, Israel

Abstract

Anisotropic volumetric acquisitions are common in clinical MRI and volume electron microscopy (vEM), where sparse through-plane sampling creates thick slices or sections that degrade orthogonal reformats and downstream analysis. We present CRIS, a cross-plane self-supervised framework for isotropic restoration without paired isotropic ground truth. CRIS casts 3D restoration as 2D stripe completion on orthogonal reformats of an isotropic grid: high-resolution in-plane slices are synthetically degraded and periodically masked for training, while at inference blank slices define the isotropic grid, two orthogonal reformats are restored, and predictions are fused by multi-view averaging. We evaluate CRIS on two MRI cohorts and two microscopy benchmarks up to 8x anisotropy. On brain MRI, CRIS achieves 32.921 +/- 0.436 dB PSNR and 0.963 +/- 0.003 SSIM, outperforming interpolation, ECLARE, SMORE4, SIMPLE, SA-INR, and ATME, and gives the best segmentation consistency (Dice 0.940 +/- 0.004, ASSD 0.245 +/- 0.014 mm, HD99 1.275 +/- 0.061 mm). On reference-free abdominal MRI, CRIS reduces FID/KID to 48.71/0.023, outperforming interpolation, ECLARE, SMORE4, and SIMPLE. On vEM, CRIS achieves 29.100 dB/0.830 3D PSNR/SSIM at 4x and 26.874 dB/0.722 at 8x on EPFL, and 21.935 +/- 0.437 dB/0.696 +/- 0.024 on noisy hemibrain data. In a dedicated robustness experiment, one variable-gap CRIS model evaluated across gap factors 3-7 and coronal, axial, and sagittal degradations maintained higher PSNR/SSIM than interpolation (36.36-31.14 dB and 0.977-0.932 vs. 33.07-27.85 dB and 0.951-0.853). These results support CRIS as a modality-flexible route to isotropic restoration without paired isotropic targets or configuration-specific retraining. Code is available at https://github.com/adi-hatav/CRIS.

Explore similar work

Aug 9, 2026cs.CV

Anatomically Consistent Cross-Contrast Super-Resolution of Anisotropic Brain T2w MRI

T2-weighted (T2w) brain MRI provides fluid-sensitive soft-tissue contrast that is important for neuro-oncology and radiotherapy planning. However, T2w scans are acquired with anisotropic voxels and appear blurred or stair-stepped on coronal and sagittal views, which obscures small structures and weakens any downstream 3D analysis. We propose VIPP-SR (View-Independent Patched Projection Super-Resolution), a cross-contrast guided super-resolution framework that restores the inter-plane resolution of an existing anisotropic T2w volume without an isotropic ground-truth T2w. VIPP-SR first trains a view-independent patched generator (VIP-GAN) to learn local T1c-to-T2w anatomical correspondence from high-resolution axial slices. The trained generator is then applied to axial, coronal, and sagittal views of the T1c volume to generate three orthogonal T2w estimates. Shape-preserving patching and deepest-skip removal reduce view-specific shortcuts, thereby constraining the generator to learn patch-local representations and enabling the zero-shot inter-plane transfer. Central to VIPP-SR, a projection-based optimization then enforces anatomical consistency across the three view-specific volumes, fusing them by balancing inter-plane self-consistency against per-view data fidelity. The generator is trained on BraTS-MET and evaluated on both the held-out BraTS-MET testing set and the BraTS-GLI cohort without retraining, assessing the cross-cohort generalizability. The results validate that VIPP-SR improves downstream segmentation over the real anisotropic T2w baseline, raising mean-label Dice from 0.330 to 0.465 on BraTS-MET and, zero-shot, from 0.473 to 0.563 on BraTS-GLI and ablation studies identify inter-plane self-consistency as the main source of the gain.
Mengqi Shen, Haicheng Wang, Meghna Trivedi +4
Jun 8, 2026eess.IV

Deep Slice Interpolation for Reducing Through-Plane Anisotropy and Noise in Head CT

Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels. We present a deep learning system that synthesizes intermediate CT slices from pairs of neighboring axial slices, halving the effective through-plane spacing. The system improves three-dimensional visualization while simultaneously producing inherently denoised outputs, yielding two complementary benefits from a single inference pass. To build a reliable system, we systematically evaluate pixel-wise losses, namely mean squared error (MSE) and mean absolute error (L1); structural-similarity losses, namely the structural similarity index (SSIM) and its multi-scale variant (MS-SSIM); and hybrid combinations. On a held-out test set, all converged models outperform classical interpolation baselines and pretrained video frame interpolation methods (RIFE, FILM) on all structural measures, with MS-SSIM+L1 offering the strongest balanced profile. We also document training instability in SSIM-family losses and identify partial remedies: the standard numerical fixes eliminate the dominant failure mode but leave residual divergence at smaller batch sizes. All results are reported with patient-level bootstrap confidence intervals and paired statistical tests. As an illustration, we apply the system to an out-of-distribution head CT series from Hospital Universitario Virgen del Rocío: the model synthesizes intermediate slices and exhibits on the real slices the implicit-denoising signature predicted by our theoretical analysis, supporting in a single external case that interpolation quality and implicit denoising are not confined to the training distribution.
Luis Cortés Ferre, Miguel A. Gutiérrez-Naranjo, Marcin Balcerzyk
Sep 1, 2026cs.CV

SliceBridge: context-consistent repair of corrupted slice intervals in T1-weighted MRI

Structural magnetic resonance imaging (MRI) images are sometimes corrupted over a contiguous set of slices, where acquisition, motion, hardware, or reconstruction effects leave a single slice or short interval inconsistent with its neighbors while the rest of the image remains usable. Such localized corruption can bias downstream morphometric analysis, yet discarding or reacquiring an otherwise usable image is costly. We formulate this as an image restoration problem: given the location of the affected interval, reconstruct those slices from the surrounding anatomical and imaging context. We propose SliceBridge, a framework for restoring corrupted slice intervals in T1-weighted MRI using rectified flow matching conditioned on the surrounding intact slices and their relative slice positions. Through-plane consistency is encouraged by coupling the slices within the interval through interval-correlated initial noise, a shared flow time, and synchronized sampling. The restored interval is then inserted back, leaving all other slices unchanged. We trained and validated the model on 9,877 T1-weighted brain MRI volumes from four datasets and evaluated it on 581 external subjects using clean interval withholding and controlled corruptions. Compared with a matched model that reconstructed target slices independently, SliceBridge reduced error in slice-to-slice changes within repaired intervals by 32.9%-41.3% across interval lengths and achieved higher SSIM at every interval length. In controlled-corruption cases, SliceBridge reduced the median error in regional brain volume estimates produced by a downstream segmentation model from 1.95% in corrupted volumes to 1.05%.
Jiheng Li, Michael E. Kim, Trent Schwartz +6