cs.CVJun 10, 2026

MedCTA: A Benchmark for Clinical Tool Agents

Authors: Tajamul AshrafHyewon JeongFida Mohammad ThokerBernard Ghanem

Organizations: King Abdullah University of Science and Technology (KAUST), Saudi Arabia · Massachusetts Institute of Technology (MIT), USA

Abstract

To make clinically grounded decisions, medical AI agents are expected to go beyond simple recognition and be capable of tool retrieval, evidence acquisition, and integration. Existing benchmarks largely evaluate isolated perception or single-turn question answering, and therefore provide limited visibility into failures of planning, tool recruitment, and rollout reliability. We introduce MedCTA, a benchmark for evaluating medical tool agents on clinician-validated, step-implicit tasks grounded in realistic multimodal clinical inputs, including radiology images, pathology slides, and reports. MedCTA comprises 107 real-world clinical tasks with clinician-verified executable trajectories over 5 deployed tools, and supports process-aware evaluation of tool selection, argument validity, execution stability, trajectory fidelity, and outcome quality. We benchmark 18 open- and closed-source multimodal models and find that even frontier systems remain brittle in multi-step clinical tool use: autonomous rollouts are dominated by protocol failures, premature stopping, and incorrect tool recruitment, while gold-standard tool routing yields large but still incomplete gains. These results show that strong backbone perception does not translate into reliable agentic behavior in clinical settings. MedCTA provides a rigorous testbed for auditing, diagnosing, and advancing trustworthy medical AI agents. The dataset and evaluation suite are available at https://ivul-kaust.github.io/MedCTA/

Explore similar work

Jul 28, 2026cs.CV

Agentic AI in medicine: architectures, applications, evaluation, and challenges for clinical translation

Large language models and multimodal foundation models are enabling medical artificial intelligence (AI) systems to move beyond isolated prediction and undertake multistep clinical tasks that require planning, tool use, memory, iterative correction, and coordination among specialized agents. However, the scope of agentic AI in medicine remains unsettled, and current evaluation practices are not yet aligned with the requirements of clinical use. We conducted a scoping review with systematic evidence mapping across five electronic sources, screened 1,649 exportable records, and provisionally included 557 unique studies that met predefined criteria for goal-directed task execution, tool use, interaction with external resources, feedback-based refinement, or multi-agent collaboration. The included studies describe single agents that use external tools, workflows supported by retrieval and external knowledge, multimodal agents, and multi-agent systems applied to medical question answering, image interpretation, electronic health record analysis, drug safety, and clinical trial prediction. The evidence base remains dominated by public benchmarks, simulated settings, retrospective datasets, and small-scale expert evaluation. Process reliability, evidence traceability, uncertainty, safety, workflow impact, and external validity are evaluated less consistently. Clinical translation will depend on clearer definitions, reproducible evaluation, auditable oversight, interoperable system design, and prospective validation in real-world clinical workflows.
Zheng Tong, Yang Liu, Wanshu Fan +6
Jun 2, 2026cs.AI

MedCUA-Bench: A Screenshot-Only Benchmark for Clinical Computer-Use Agents

Computer-use agents could automate repetitive screen-based clinical work, but their reliability in medical graphical user interfaces remains largely unvalidated. Existing benchmarks focus on general web or desktop tasks and underrepresent medical software, which requires domain knowledge, exhibits markedly different UI design from mainstream applications, lacks public testing environments, and demands safety validation beyond task completion. We introduce MedCUA-Bench, an interactive benchmark for clinical computer-use agents. It covers 18 clinical scenarios across 10 medical domains, reconstructed from real product manuals and open-source medical systems to capture authentic clinical interfaces while avoiding licensing and privacy constraints. Each task ships with paired intent- and step-level goals to disentangle clinical reasoning from UI execution, and is evaluated by a deterministic checker over task completion and five clinical safety dimensions. Across 23 agents, the best closed-source model reaches 54.2% strict success, while all models remain below 9% on the real OpenEMR. Open-source agents average only 2.5%, with the best reaching 16.2%. MedCUA-Bench exposes the gap between current agents and reliable clinical software use, providing a reproducible testbed for future research.
Jia Yu, Zilong Wang, Xinyang Jiang +2
Jun 23, 2026cs.CL

MedBench v5: A Dynamic, Process-Oriented, and Hallucination-Aware Benchmark for Clinical Multimodal Models

Existing medical AI benchmarks lack process visibility, atomic skill evaluation, and integrated hallucination detection. We introduce MedBench v5, a redesigned benchmark for clinical multimodal models (language, vision-language, and agent systems) that moves from static QA to dynamic, process-oriented evaluation. MedBench v5 features: (1) a dual-dimensional framework combining Clinical Cognitive Responsiveness (13 sub-dimensions) and Medical Atomic Skills (4 agent environments), covering 63 tasks; (2) three switchable information-flow stressors (omission, contradiction, evidence delay) for factorized degradation analysis; (3) a dynamic process audit protocol with five reasoning nodes that produces model-specific failure fingerprints; (4) hallucination propagation monitoring across initiation, propagation, anchoring, and contradiction interaction-capturing silent hallucination. Experiments on frontier models show that strong overall task performance does not guarantee process stability: stressors mainly disrupt contradiction detection, diagnosis updating, hallucination propagation, and contradiction-based self-correction, while final evidence grounding can remain superficially stable. MedBench v5 provides a unified infrastructure for capability profiling, controllable stress testing, process auditing, and hallucination trajectory analysis in clinical AI evaluation.
Jinru Ding, Chuchu Jiang, Lu Lu +12