cs.AIJun 10, 2026

Reducing the Complexity of Deep Learning Models for EEG Analysis on Wearable Devices

Authors: Farough Shayeste RoodiParham Zilouchian MoghaddamMahdi Mohammadi-nasabMehdi ModarressiMostafa Ersali Salehi NasabMasoud Daneshtalab

Organizations: School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran · Intelligent Future Technologies (IFT), Mälardalen University, Väster˚as, Sweden · Department of Computer Systems, Tallinn University of Technology (TalTech), Tallinn, Estonia

Abstract

Wearable healthcare devices are the fastest-growing Internet of Things (IoT) sector. Many automated healthcare services rely on two crucial biological signals, namely ECG and EEG, which reflect the activity of the heart and brain, respectively. Although deep neural networks are considered the primary way to process and analyze these signals, the very tight energy and computational power constraints in wearable devices are far below the computational, energy, and memory bandwidth demands of DNN models, thereby impeding the deployment of deep learning in many practical wearable services. This paper investigates the feasibility of deploying state-of-the-art DNN models in resource-constrained wearable devices. Notably, we explore the trade-off between accuracy and computational complexity of DNNs when parameter quantization and electrode reduction methods are used. Our investigation centers on several state-of-the-art DNN models designed for EEG signal analysis, specifically for detecting epileptic seizures. Our findings demonstrate that, when applied judiciously, these techniques can significantly reduce the complexity of the DNNs under consideration with minimal adverse effects on accuracy. These results reveal the explicit trade-offs between accuracy and complexity reduction encountered when adapting DNN-based online EEG analysis for wearable devices.

Explore similar work

Sep 14, 2026cs.HC

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

The growing use of electroencephalography (EEG) motivates automated analysis that is accurate, transferable, and deployable on constrained hardware. Recent EEG foundation models learn general representations from large-scale pretraining, but their size and computational cost limit edge and wearable deployment. We introduce BRIDGE-EEG, an efficient multi-task EEG classification pipeline that preserves the benefits of pretraining while reducing model size. A unified preprocessing scheme maps heterogeneous recordings with different channel counts, montages, and sampling rates to a device-agnostic 62-channel time--frequency representation. We pretrain an SE-ResNet18 teacher (11.84 M parameters) with SimCLR on unlabeled EEG from five heterogeneous datasets, then compress it into SE-ResNet8 (1.56 M) and SE-ResNet4 (0.48 M) students using task-agnostic and task-specific distillation. We evaluate six benchmarks spanning abnormality detection, motor imagery, and emotion recognition. For abnormality detection and emotion recognition, the students achieve accuracy comparable to or better than several recent EEG foundation models with 10--1,000×\times more parameters. Motor imagery shows a remaining representation gap, highlighting the importance of pretraining diversity. Inference profiling on a server GPU, desktop CPU, and NVIDIA Jetson Orin Nano shows up to 3.0×\times lower edge energy per inference (15.64 mJ vs. 46.67 mJ). The compact models further support future deployment on MCU-class wearables.
Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu +2
Aug 7, 2026cs.AI

ZIPBrain: Can EEG Foundation Models Be Faster, Locally Deployable, but Accurate?

This work investigates whether Electroencephalograph (EEG) foundation models (EFMs) can be made faster and locally deployable without sacrificing accuracy. EEG foundation models are a major trend, offering strong general-purpose representations. However, their computational burden grows quadratically with input length, hindering deployment on resource-constrained scenario, particularly for real-time clinical monitoring. EEG's low SNR further suggests many of these tokens are redundant and compressible with little accuracy cost. We propose ZIPBrain, a novel redundancy-aware EEG token pooling module that leverages this low-SNR characteristic to reduce token count. Given a token sequence, ZIPBrain partitions tokens into redundant and unique groups, then merges each redundant token with its most similar counterpart in the unique group. Furthermore, ZIPBrain serves as a training-free, plug-and-play module that seamlessly integrates into standard Transformer encoders with negligible computational overhead. Extensive experiments across multiple EEG foundation models show ZIPBrain's strong versatility, achieving 1.3%-10.5% average improvement over baselines, while reducing wall-clock inference time by 32.7% (up to 41.8% with CUDA Graph) compared to the original EEG foundation models.
Lingwei Li, Yirong Kan, Peng Chen +3
Jun 20, 2026cs.LG

From Handcrafted Features to Functional Edge Learning: Evolution of EEG Seizure Detection Frameworks

Electroencephalogram (EEG) analysis remains the clinical gold standard for epilepsy diagnosis and seizure detection. While Deep Learning (DL) has significantly advanced automated EEG interpretation, its transition from controlled experimental settings to routine clinical deployment is severely bottlenecked by fundamental architectural flaws. Standard DL models operate as opaque black-boxes lacking clinical interpretability, demand massive amounts of balanced annotated data, and incur steep computational costs incompatible with resource-constrained wearable or implantable neuromodulation devices. This paper presents a comprehensive review of these prevailing limitations and explores Kolmogorov-Arnold Networks (KANs) as a emerging paradigm for EEG-based seizure detection. By replacing the fixed activation functions of traditional neurons with flexible, learnable functions along the network's connections, KANs bridge the critical gap between predictive accuracy and mathematical transparency. We systematically analyze how KAN architectures resolve the shortcomings of traditional DL-based models by offering exceptional parameter efficiency, inherent interpretability for physician trust, and robust performance under data scarcity. Ultimately, this review establishes KANs not merely as an incremental algorithmic update, but as a fundamental paradigm shift necessary to actualize next-generation, patient-specific, and thoroughly transparent clinical EEG monitoring systems.
Sepideh Kheirollahi, Mohammad Rasoul Roshanshah