Leptomeningeal Collateral Detection on DSA via Vessel-Graph Neural Networks
Authors: Junyong Cao, Hakim Baazaoui, Chinmay Prabhakar, Suprosanna Shit, Lukas Bastian Otto, Susanne Wegener, Bjoern Menze, Ezequiel de la Rosa
Organizations: University of Zurich, Zurich, Switzerland · University Hospital Zurich, Zurich, Switzerland
Abstract
Leptomeningeal collaterals (LMCs) are an important prognostic factor in acute ischemic stroke. Existing automated methods rely on CT angiography (CTA), but individual LMCs are often too small to be resolved on CTA, limiting these methods to coarse collateral scoring. Digital subtraction angiography (DSA) visualizes individual collaterals at superior resolution, yet current assessment remains subjective, relying on manual grading scales that suffer from poor inter-rater agreement. We present a framework that formulates collateral detection as the classification of individual vessel segments on a graph derived from DSA. A hybrid graph-pixel architecture combines a topology-aware graph branch with a dense pixel branch, fused in a shared node-probability space. In a five-fold cross-validation setting, the fused model achieves a PR-AUC of 0.434, outperforming the graph-only (0.403) and pixel-only (0.362) baselines. To our knowledge, this is the first method to enable the individualization of LMCs in DSA, allowing for precise per-vessel quantitative assessment. This integration shifts DSA assessment toward objective evaluation, supporting future biomarker and pattern discovery for individual LMCs.
Digital subtraction angiography (DSA) in coronary imaging is fundamentally challenged by physiological motion, forcing reliance on raw angiograms cluttered with anatomical noise. Existing deep learning methods often produced images with two critical clinically unacceptable flaws: persistent boundary artifacts and a loss of native tissue grayscale fidelity that undermined diagnostic confidence. We propose a novel framework termed as CDSA-Net that for the first time explicitly decouples and jointly optimizes vascular structure preservation and realistic background restoration. CDSA-Net introduces two core innovations: (i) A hierarchical geometric prior guidance (HGPG) mechanism, embedded in our coronary structure extraction network (CSENet). It synergistically combines integrated geometric prior (IGP) with gated spatial modulation (GSM) and centerline-aware topology (CAT) loss supervision, ensuring structural continuity. (ii) An adaptive noise module (ANM) within our coronary background restoration network (CBResNet). Unlike standard restoration, ANM uniquely models the stochastic nature of clinical X-ray noise, bridging the domain gap to enable seamless background intensity estimation and the complete elimination of boundary artifacts. The final subtraction is obtained by removing the restored background from the raw angiogram. Quantitatively, it significantly outperformed state-of-the-art methods in vascular intensity correlation and perceptual quality. A 25.6% improvement in morphology assessment efficiency and a 42.9% gain in hemodynamic evaluation speed set a new benchmark for utility in interventional cardiology, while maintaining diagnostic results consistent with raw angiograms. The project code is available at https://github.com/DrThink-ai/CDSA-Net.
Aims: Coronary microvascular dysfunction (CMVD) affects approximately 40%-60% of patients with ischemia and non-obstructive coronary arteries, yet diagnosis remains challenging due to reliance on invasive functional testing or subjective Thrombolysis In Myocardial Infarction (TIMI) flow grade. The TIMI Myocardial Perfusion Frame Count (TMPFC) offers an objective, angiography-based quantitative measure of CMVD, but its clinical translation is hindered by cumbersome manual calculation and insufficient validation. This study aims to develop and validate a deep learning-powered TMPFC calculation (DL-TMPFC), enabling integration into clinical workflows. Methods and results: DL-TMPFC framework comprised two components. A stenosis detection network first excluded obstructive coronary artery disease (CAD). A territory-aware segmentation network then identified perfusion territories and TMPFC calculation module automatically determined the first and last frames from angiographic sequences. The framework was validated in a cohort of 655 patients (445 of obstructive CAD, 100 of confirmed CMVD, 110 of control group) from three independent institutions. DL-TMPFC showed excellent agreement with expert manual measurements (bias: -0.93 frames; 95% LoA: -5.33 to +3.47; r =0.98). DL-TMPFC markedly enhanced clinical feasibility by fully automating TMPFC and removing observer dependence. Clinically, DL-TMPFC accurately identified CMVD across a full spectrum of coronary pathologies and captured the continuous severity of CMVD beyond binary classification, enabling quantitative risk stratification. Conclusion: DL-TMPFC enabled automatic, standardized, and accurate quantification of CMVD directly from routine angiography. By providing an automatic and objective measure, this tool provided immediate diagnostic information for timely recognition and management of CMVD in clinical practice.
Accurate coronary Digital Subtraction Angiography (DSA) vessel segmentation is essential for computer-aided diagnosis and treatment planning of coronary artery disease (CAD). However, thin low-contrast vessels, background interference, and severe vessel-background class imbalance make reliable segmentation of weak distal branches and vessel boundaries challenging. Existing methods struggle to balance global contextual reasoning with preservation of weak vessels, vessel continuity, and fine boundaries. To address these limitations, we propose HTC-SGA Former, a lightweight hybrid Transformer-CNN framework for coronary DSA vessel segmentation. It employs a CNN encoder for local vessel morphology extraction and a Transformer decoder for contextual feature modeling. A Multi-Scale Global-Local Window Attention (MS-GLWA) block performs efficient global-local contextual modeling, while a Self-Guided Feature Attention (SGFA) module enhances weak-vessel responses. In addition, a Boundary-Weighted Adaptive Compound Loss (BWACL) emphasizes thin-vessel boundaries and adaptively balances vessel recovery and boundary refinement. Experiments on private right and left coronary artery DSA subsets show that HTC-SGA Former outperforms 14 state-of-the-art segmentation methods while maintaining a compact architecture with only 0.81M parameters. BWACL also improves performance over binary cross-entropy and Dice losses across four encoder-decoder architectures, demonstrating strong cross-backbone applicability. HTC-SGA Former improves thin-vessel recovery, vessel continuity, and boundary localization through complementary global-local contextual modeling, vessel-focused refinement, and adaptive optimization, supporting reliable and computationally efficient coronary vessel analysis for future computer-assisted cardiovascular interventions.
Rayan Merghani Ahmed, Marwa Omer Mohammed Omer, Mohamed Elmanna +3