cs.CVJun 19, 2026

Native space based pipelines outperform template space based pipeline in subcortical segmentation

Authors: Tomás LimaDaniel NovákEduard Bakštein

Organizations: Department of Cybernetics, Czech Technical University in Prague, Prague, Czech Republic · National Institute of Mental Health, Klecany, Czech Republic

Abstract

Accurate segmentation of subcortical regions is critical for neurosurgical planning and functional research. Most automated methods rely on template space coregistration, which may compromise patient-specific accuracy, particularly in small structures. We identify a need to evaluate whether native space approaches offer a measurable advantage, which we evaluate in the context of movement disorders. We developed two UNet-based segmentation pipelines of the Subthalamic Nucleus (STN) - a common surgical target in Parkinson's Disease - and the neighbouring Red Nucleus (RN) and Substantia Nigra (SN). We collected 7T and 3T MRI data from five public datasets. The pipelines were evaluated in the native-space against manual labels. We further investigated the effect of the template resolution. Motivated by the hypothesis that models may better learn target boundaries in higher field, we tested the transferability of 7T-trained models to 3T clinical images, and whether synthetic 3T training data - generated via a disentangled representation learning method - could help bridging this domain gap. On held-out 7T data, the native pipeline consistently outperformed the template one. For the STN, native-space Dice reached 0.775 +- 0.055 versus 0.713 +- 0.051 (1 mm template), with HD95 of 0.79 +- 0.24 mm versus 1.17 +- 1.10 mm, respectively. Similar advantages were observed for the RN and SN. Increasing template resolution did not improve accuracy. When applied to 3T images, all models showed a considerable performance drop. Adding synthetic 3T data yielded only modest improvements, though without degrading 7T performance. Native-space segmentation is preferable for applications requiring patient specific anatomical fidelity, such as the surgical planning in PD. Bridging the 7T-to-3T domain gap remains an open challenge, motivating future work on domain adaptation tailored to subcortical structures.

Explore similar work

Date pendingeess.IV

Subcortical Masks Generation in CT Images via Ensemble-Based Cross-Domain Label Transfer

Subcortical segmentation in neuroimages plays an important role in understanding brain anatomy and facilitating computer-aided diagnosis of traumatic brain injuries and neurodegenerative disorders. However, training accurate automatic models requires large amounts of labelled data. Despite the availability of publicly available subcortical segmentation datasets for Magnetic Resonance Imaging (MRI), a significant gap exists for Computed Tomography (CT). This paper proposes an automatic ensemble framework to generate high-quality subcortical segmentation labels for CT scans by leveraging existing MRI-based models. We introduce a robust ensembling pipeline to integrate them and apply it to unannotated paired MRI-CT data, resulting in a comprehensive CT subcortical segmentation dataset. Extensive experiments on multiple public datasets demonstrate the superior performance of our proposed framework. Furthermore, using our generated CT dataset, we train segmentation models that achieve improved performance on related segmentation tasks. To facilitate future research, we make our source code, generated dataset, and trained models publicly available at https://github.com/alxw0671/CT_Subcortical_Segmentation, marking the first open-source release for CT subcortical segmentation to the best of our knowledge.
Augustine X. W. Lee, Pak-Hei Yeung, Jagath C. Rajapakse
May 14, 2026cs.CV

Automatic Landmark-Based Segmentation of Human Subcortical Structures in MRI

Precise segmentation of brain structures in magnetic resonance imaging (MRI) is essential for reliable neuroimaging analysis, yet voxel-wise deep models often yield anatomically inconsistent results that diverge from expert-defined boundaries. In this research, we propose a landmark-guided 3D brain segmentation approach that explicitly mimics the manual segmentation protocol of the Harvard--Oxford Atlas. A Global-to-Local network automatically detects 16 landmarks representing key subcortical reference points. Then, a semantic segmentation model produces a coarse segmentation of 12 anatomical labels, each grouping multiple subcortical regions. Finally, a landmark-driven post-processing step separates these 12 labels into 26 distinct structures by enforcing local anatomical constraints. Experimental results demonstrate consistent improvements in boundary accuracy. Overall, integrating learned landmarks aligns segmentations more closely with manual protocols.
Ahmed Rekik, R. Jarrett Rushmore, Sylvain Bouix +1
May 21, 2026cs.CV

SegGuidedNet: Sub-Region-Aware Attention Supervision for Interpretable Brain Tumor Segmentation

Accurate segmentation of brain tumour sub-regions from multi-parametric MRI is critical for treatment planning yet remains challenging due to morphological variability, class imbalance, and overlapping appearances of tumour regions across imaging sequences. We propose SegGuidedNet, a three-dimensional residual encoder--decoder network introducing a novel SegAttentionGate module that explicitly supervises the decoder to produce spatially discriminative attention maps for each tumour sub-region necrotic core, peritumoral oedema, and enhancing tumour via a lightweight auxiliary loss, adding less than 0.2% parameter overhead. This sub-region supervision maintains decoder discriminability between visually ambiguous classes while providing free-of-cost spatial interpretability at inference without any post-hoc explanation method. Evaluated independently on BraTS2021 and BraTS2023 GLI across 251 held-out subjects each, SegGuidedNet achieves mean Dice of 0.905 (ET= 0.873, TC=0.906, WT=0.935) and 0.897 (ET=0.859, TC=0.902, WT=0.931) respectively, surpassing ensemble-based nnU-Net and HNF-Netv2 as a single model and approaching Swin UNETR a 10-model ensemble within 2--4 Dice points at a fraction of the inference cost. The consistency of results across two benchmark editions further confirms the generalisability of the proposed approach, offering competitive accuracy with built-in interpretability in a lightweight, clinically practical framework.
Hasaan Maqsood, Saif Ur Rehman Khan, Sebastian Vollmer +2