Unsupervised Susceptibility Distortion Correction of EPI without Calibration Scans via Image Translation-Based Registration

Authors: Wooseung Kim, Sung-Hong Park

Abstract

Functional magnetic resonance imaging (fMRI) utilizes echo-planar imaging (EPI) to capture blood-oxygen-level-dependent (BOLD) signals with high temporal resolution. However, EPI is inherently sensitive to magnetic field inhomogeneities, resulting in susceptibility-induced geometric distortions along the phase-encoding (PE) direction. To correct these distortions, conventional approaches rely on additional calibration scans, such as field maps or reverse PE acquisitions, which are not always available in practice. To overcome this limitation, we propose SACRED, a calibration scan-free susceptibility distortion correction framework that corrects geometric distortions via image translation-based registration using only a routinely acquired anatomical T1-weighted (T1w) image and a unidirectional PE BOLD image. SACRED employs an invertible neural network as the image translation backbone to bridge the contrast gap between BOLD and T1w images while enforcing structural consistency through a modality independent neighborhood descriptor. This design enables the use of a mono-contrast similarity objective to train the registration network in an unsupervised manner without requiring distortion-corrected BOLD images. In addition, we incorporate test-time adaptation (TTA) to further enhance performance on out-of-distribution (OOD) data at inference time. SACRED was evaluated on one in-distribution (ID) dataset and two OOD datasets, and was compared with representative fMRI distortion correction methods. The results demonstrate that SACRED significantly outperforms competing methods on both ID and OOD datasets, exhibiting robustness to scanner and population shifts, partly enabled by TTA. The code will be made publicly available upon acceptance.

Explore similar work

Jun 30, 2026eess.IV

Distortion-Corrected Diffusion MRI Using Rotated-View EPI and Joint Field-Map/Image Estimation with Gaussian Primitives

Echo Planar Imaging (EPI) is the standard acquisition technique for diffusion and functional neuroimaging, enabling rapid imaging but suffering from geometric distortions caused by B0 field inhomogeneities. Existing correction methods first reconstruct distorted images using parallel imaging, then estimate the B0 field and correct the distortion in the image domain. In this sequential process, reconstruction artifacts at high acceleration factors and low SNR at high diffusion b-values degrade B0 estimation and limit the overall correction quality. We propose a physics-informed framework that jointly estimates the B0 field and distortion-free image directly from k-space data, without depending on an intermediate parallel-imaging reconstruction for the correction. The image and the B0 field are each represented as a superposition of Gaussian primitives embedded within an MRI physics forward model. The explicit, continuous parameterization captures both smooth regions and tissue boundaries and supports rotated-view EPI acquisitions without interpolation. The diffusion-weighted image is modeled as real and non-negative, with the image phase absorbed into a per-shot phase factor. Rotated views distribute distortions across multiple phase-encoding orientations, improving point spread function isotropy and providing stronger constraints for B0 estimation. On in vivo brain diffusion EPI, the proposed method attains the closest brain-boundary agreement with a distortion-free structural reference, with the largest improvement over sequential methods at high b-value and high acceleration. Extensive visual comparisons further show improved detail fidelity and noise suppression.
Wenqi Huang, Zhitao Li, Nan Wang +8
Jul 28, 2026cs.CV

Eddeep: a deep-learning framework for fast eddy-current distortion correction in diffusion MRI

Diffusion MRI (dMRI) relies on diffusion-weighted echo-planar imaging, which is highly susceptible to eddy-current-induced geometric distortions. These distortions vary across diffusion volumes according to gradient strength and direction, causing between-volume misalignment that can bias downstream microstructural analyses. Current state-of-the-art correction methods, such as FSL Eddy, achieve high-quality correction through iterative prediction-correction schemes but are computationally expensive. We propose Eddeep, a deep-learning framework for fast eddy-current distortion correction in dMRI. Eddeep decomposes the problem into two stages. First, a supervised image translation network standardises the appearance of diffusion-weighted and b=0 images, removing contrast differences that hinder reliable registration. Second, an unsupervised registration network estimates both eddy-current distortion and between-volume head motion parameters under a physics-constrained quadratic distortion model, enabling correction in a single forward pass. The method was trained on UK Biobank data and evaluated on both in-domain (UK Biobank) and out-of-domain (Memodyn) datasets. Across a range of complementary metrics, including between-volume jitter, diffusion kurtosis imaging residuals, signal irregularity, and mutual information, Eddeep achieved correction quality comparable to that of FSL Eddy while substantially reducing inference time. These results demonstrate that deep learning can provide accurate and efficient eddy-current distortion correction without relying on iterative optimisation, supporting the development of faster diffusion MRI processing pipelines for large-scale studies and clinical deployment. The code is available at: https://github.com/CIG-UCL/eddeep.
Antoine Legouhy, Ross Callaghan, Yuchuan Qiao +4
Aug 8, 2026eess.IV

DisMorph\texttt{DisMorph}: learning to disentangle technical distortions from true biological change

Longitudinal MRI enables sensitive measurement of structural brain change for studying aging and neurodegenerative disease. Deformable image registration is a key tool for estimating such change by computing a dense deformation that captures geometric differences between longitudinal scans. However, MRI scanners introduce geometric distortions that vary across acquisition systems and protocols, such as gradient non-linearity (GNL) distortion. Existing registration methods estimate a single field that conflates biological and technical effects, potentially biasing downstream morphometric measurements if distortions remain (partially) uncorrected. We propose DisMorph\texttt{DisMorph}, a registration framework trained entirely on synthetic data that explicitly decomposes longitudinal deformation into technical and anatomical transforms. It predicts two dense deformations, each encoding one effect. During training, a novel generative model synthesizes both effects separately to provide disentanglement supervision, while domain randomization promotes generalization across imaging protocols. We evaluate our method in three complementary settings. On simulated data with known ground truth, our method detects anatomical change more accurately and consistently than conventional registration. On real image pairs that differ only by GNL distortion, our method assigns most geometric change to the distortion field, demonstrating specificity in the absence of anatomical change. On longitudinal Alzheimer's disease (AD) pairs, our method detects anatomical change in AD-related brain structures while identifying residual distortion left after standard correction. By disentangling MRI-induced distortion from biological change in the longitudinal deformation, our method paves the way for more accurate longitudinal morphometry in clinical settings where maintaining acquisition consistency is challenging.
Jingru Fu, Kathleen E. Larson, Douglas N. Greve +2